1. Introduction

This paper, one of a set associated with the 2013 release of data from the Planck1 mission (Planck Collaboration I 2014), describes the techniques we employed to calibrate the voltages measured by the LFI radiometers into a set of thermodynamic temperatures (photometric calibration). We also discuss the quality of our calibration in terms of the required accuracy needed to achieve Planck’s final science goals. This paper is part of a larger set of articles (Planck Collaboration II 2014; Planck Collaboration III 2014; Planck Collaboration IV 2014) which explain the methodology used to produce maps from raw LFI data which have been issued in the Planck 2013 data release. A similar paper, Planck Collaboration VIII (2014), describes the approach used by HFI. Planck Collaboration XXXI (2014) contains a comparison of the LFI/HFI approaches and assess the consistency of Planck’s maps and power spectra.

By “calibration” here we mean the process that converts each voltage measured by an analogue-to-digital converter (ADC) into a thermodynamic temperature. (We describe the incoming flux as a thermodynamic temperature because the cosmic microwave background (CMB) signal is a nearly perfect blackbody, and thus the temperature is a more physically significant quantity to measure.) The process can be modelled by the following equation: Vout(t)=G(t)×[B(Tsky+D)]x(t),t+M,\begin{equation} \label{eq:calibrationEquation} V_\mathrm{out}(t) = G(t)\times\Bigl[B * \bigl(T_\mathrm{sky} + D\bigr)\Bigr]_{\xversor(t), t} + M, \end{equation}(1)where x(t) is the direction of the beam axis at time t. This relates the voltage Vout measured by the ADC with the sum of three terms: (1) the convolution2 between the brightness temperature Tsky of the sky (CMB and galactic/extragalactic foregrounds) and the beam response B of the instrument (4πB dΩ = 1) at a given time; (2) the convolution between B and the CMB dipole D (including the solar and orbital terms, as well as their associated kinematic quadrupoles); and (3) an offset term M (monopole, including instrumental offsets), which is of little importance for differential instruments3 like LFI. (The dependence of the B ∗ (Tsky + D) term on both x and t, expressed in Eq. (1) by a subscript, is due to the fact that D depends on the velocity of Planck, which is a time-dependent quantity.) The transfer function G represents the overall “gain” of the instrument. We are primarily interested in K = G-1, as the purpose of the calibration is to convert V back into a temperature. Since a number of environmental factors influence the value of K, we expect it to change with time. The output of a calibration procedure is therefore a time series of values Ki, which sample the unknown function K(t) at a reasonable frequency (i.e., higher than the frequency of the expected instrumental fluctuations in K) and which allow us to reconstruct the value of BTsky in Eq. (1) with good accuracy (for LFI, this accuracy is between 0.6 and 0.8%, with 0.25% of uncertainty coming from the error bars on the characterization of the CMB dipole provided by WMAP).

Proper relative calibration (i.e., precise tracking of the variations of each radiometer’s gain throughout the mission) is a necessary condition for a self-consistent map-making. In addition, accurate determination of the absolute calibration (i.e., translation of the observed voltages into physical units, in terms of antenna temperature), together with proper reconstruction of the beam window function, is crucial for any scientific exploitation of the maps and power spectra. The LFI calibrated maps are used extensively in the Planck data analysis. They are a fundamental input to the component separation process (Planck Collaboration XII 2014), which leads to Planck’s full-sky CMB map. This map is the basis for the extraction of the Planck power spectrum in the low-multipole regime (Planck Collaboration XV 2014), and for all analyses on non-Gaussianity (Planck Collaboration XXIV 2014), isotropy, and second-order statistics (Planck Collaboration XXIII 2014). Furthermore, the LFI power spectrum provides a unique consistency check internal to Planck, particularly in the comparison between the LFI 70 GHz and the HFI 100 GHz channels (Planck Collaboration XXXI 2014). The LFI beams and window functions are discussed in detail in Planck Collaboration IV (2014). Here we give a detailed account of the LFI absolute and relative calibration. Earlier accounts of the calibration procedure for LFI were given by Villa et al. (2010) and Mennella et al. (2010), which present the results of the LFI on-ground calibration campaign, and by Mennella et al. (2011), which describes the LFI calibration procedure used for producing the Planck Early Results (Planck Collaboration I 2011).

The structure of this paper is the following. In Sect. 2 we introduce a number of important ideas that are going to be used in this work, namely the time scales of variations in K (Sect. 2.1), the treatment of beam sidelobes in the calibration and their impact on subsequent analyses of LFI’s calibrated data (Sect. 2.2), and an updated list of colour corrections (Sect 2.3). Then, in Sect. 3, we explain the methods we have developed to calibrate the data acquired by the LFI radiometers. We discuss the type of systematic effects affecting the calibration procedure in Sect. 4. In Sect. 5 we estimate the accuracy of our calibration, and we include the most relevant results from Planck Collaboration XXXI (2014), which compares LFI results to HFI as well as WMAP. Finally, in Sect. 6 we summarize our results and propose a number of improvements to be implemented for the future releases of LFI data.

2. Calibration philosophy and conventions

2.1. Time scale of gain variations

In this section we establish the time scale over which we expect significant variations in the gain of the LFI radiometers. This quantity drives the design of the calibration algorithms we then discuss in the next sections.

Changes in the gain of the LFI radiometers are mainly triggered by changes in the thermal environment of the LFI instrument, particularly in the front-end and back-end modules (Bersanelli et al. 2010). The time scale of gain changes can therefore be estimated either by considering the rate of change of temperature sampled near the radiometer amplifiers, or by using the radiometer to continuously measure the temperature of a load kept at a stable temperature. The latter solution is viable for LFI, because each radiometer continuously observes a stable 4 K load mounted on the external shield of HFI (Valenziano et al. 2009; Lamarre et al. 2010); the temperature of each 4 K load drifts by less than one mK per year (so that the ratio of a yearly drift to the system temperature, Tsys ≈ 20 K, is 0.01%), and the 4 K signal entering LFI radiometers goes through the same chain as the signal coming from the telescope. It can therefore be used to assess the rate of change in the gain with good accuracy.

thumbnail Fig. 1

Fourier transforms of the temperatures of the focal plane (Tfp, sensor TS5R) and the back-end (Tbe, sensor R_BEM1) measured during the first three months of data acquisition. Apart from the daily fluctuation induced by the transponder, there are no significant peaks at high frequencies.

Despite the fact that Planck orbits around the Sun-Earth L2 point, which grants a stable thermal environment (Tauber et al. 2010), there are, however, some phenomena that can induce variations in the temperature near the amplifiers:

  • 1.

    Fluctuations in the temperature of the 20 Ksorption cooler cold end (PlanckCollaboration II 2011). The cycleperiod of each cooler’s bed is of the order of tens of minutes, but theinduced change of temperature in the focal plane is minimal (lessthan 0.01%). We must move to much longer time scales (i.e.,weeks) to see significant variations in the temperature.

  • 2.

    Fluctuations in the temperature of the warm back-end of the radiometers. The biggest variations we experienced during the mission are due to the continuous turning on/off of the transponder antenna (used to send data to Earth) early in the mission, which followed a duty cycle of 24 h and induced 17 mK peak-to-peak fluctuations (over an average temperature of ~290 K) in the temperature near the back-end amplifiers.

This is well represented by Fig. 1, which shows that the power spectrum of the thermal fluctuations measured on the focal plane and in the back-end modules has a high low-frequency part, but it has negligible power at time scales shorter than one day. (The peak caused by the transponder switching is clearly visible in the spectrum of Tbe.)

We do not expect significant variations in the gain of the radiometers on timescales shorter than these, i.e., tens of hours. To make our discussion more quantitative, we can estimate the rate of change of a temperature or output voltage f(t) by means of the following parameter4: τf(t)=ε|f(t)dfdt(t)|,\begin{equation} \label{eq:rateOfChange} \tau_f(t) = \varepsilon\left|\frac{f(t)}{\frac{\ud f}{\ud t}(t)}\right|, \end{equation}(2)which has the unit of time and quantifies the typical time required to induce a change of level ε in f at time t. Using ε = 0.01 (i.e., we are looking for 1% changes), we find the following timescales:

  • 1.

    Fluctuations in the temperature Tfp of the focal plane happen on timescales of the order of weeks.

  • 2.

    The time scale for fluctuations in the temperature Tbe of the back-end are faster during the first survey, as τTbe is of the order of tens of hours. After the first survey5 the transponder was left on continuously, and this value increases to roughly one week.

  • 3.

    Results similar to those for the back-end are found when considering the total-power voltage Vref, which measures the temperature of the 4 K loads (i.e., setting f equal to Vref instead of Tfp or Tbe).

These results motivate the need to re-calibrate each radiometer more than once per day. The most natural length of time for Planck is the duration of one pointing period, i.e., the interval between two consecutive repointings of the spacecraft, which happens roughly once per hour (Dupac & Tauber 2005) and is short enough to detect any significant change in the gains. At the same time, the interval is long enough to sample the dipole signal (our main calibration source) with good signal-to-noise ratio (S/N), since during one pointing period the telescope scans the same circle in the sky tens of times (the median value is 39 times, and 50% of the pointings fall in the 36–42 range).

For this data release we chose not to explicitly consider effects due to the aging of the radiometric components and variations in the emissivity of the telescope. Such phenomena can lead to variations in the gain, noise temperatures, or an increase in the instabilities of the instrument, but we have had no clear evidence that they are significant on the relatively short time span covered by this data release (one year and a half). In September-October 2013 we have run a number of End-of-Life tests on the instrument, with the purpose of quantitatively assessing such effects: we will present the results of our analysis in a future Planck data release.

2.2. Handling beam efficiency

As described by Bersanelli et al. (1997), Cappellini et al. (2003), and Mennella et al. (2011), the calibration of LFI is referenced to the dipole signal, which is a nearly ideal calibrating source. Since Planck observes the sky by spinning around the Sun-Earth axis with a speed of 1 rpm (Tauber et al. 2010), and since the main beams are located at ~85° from the spinning axis, the dipole induces a sinusoidal fluctuation in the time ordered data with frequency 1/60 Hz and varying amplitude6 which can be used for the calibration. For this release, our reference dipole Dref is the combination of the solar dipole as given by the WMAP values (Jarosik et al. 2011), and the orbital dipole, derived from the known velocity of the Planck spacecraft relative to the barycentre of the solar system. We now describe the calibration procedure for LFI and, in particular, we discuss how non-ideal beams affect the process. This discussion is similar to the one carried on in Planck Collaboration XXXI (2014). However, here we provide a more rigorous treatment which involves a description of the relevant quantities as a function of time rather than as a function of the observing direction.

thumbnail Fig. 2

Simulated main meam pattern for beams at the three frequencies: LFI18M (70 GHz, 13.́41 FWHM), LFI24M (44 GHz, 23.́23), and LFI27M (30 GHz, 33.́06). The beams have been calculated using GRASP.

The starting point of our discussion is Eq. (1). In the LFI pipeline (Planck Collaboration II 2014) we remove7 the Tsky term from the data, so that the equation reduces to the following: Vout(t)=G(BD)(x(t),t)+M,\begin{equation} \label{eq:gainFittingTrue} V'_\mathrm{out}(t) = G (B * D) \bigl(\xversor(t), t\bigr) + M, \end{equation}(3)where we indicate with Vout\hbox{$V'_\mathrm{out}$} the signal Vout without the Tsky component. This signal is compared with a model of the beam-convolved dipole, based on the beam response Bmodel and on the reference dipole Dref: Vout(t)=˜G(BmodelDref)(x(t),t)+˜M.\begin{equation} \label{eq:gainFittingFirstStep} V'_\mathrm{out}(t) = \tilde G (B_\mathrm{model} * D_\mathrm{ref}) \bigl(\xversor(t), t\bigr) + \tilde M. \end{equation}(4)The LFI beams are discussed in Planck Collaboration IV (2014, main beams and window functions) and Planck Collaboration III (2014, sidelobes); Fig. 2 shows three typical beam profiles in the [− 5°,5°] range. The unknown parameters ˜G\hbox{$\tilde G$} and ˜M\hbox{$\tilde M$} in Eq. (4) can be found by means of a least square fit between Vout and the right hand side. (Such fit is done once per each pointing period, i.e., the period between two consecutive repointings of the spacecraft, which happens roughly once per hour.) From the point of view of the LFI calibration, the ˜G\hbox{$\tilde G$} factor is the only important parameter to estimate. To estimate it, we equate Eqs. (3) and (4) and take the time derivative t of the two8 sides: ˜G=Gt(BD)t(BmodelDref)·\begin{equation} \label{eq:gainReconstructionWithSidelobes} \tilde{G} = G \frac{\timeder(B*D)}{\timeder\bigl(B_\mathrm{model} * D_\mathrm{ref}\bigr)}\cdot \end{equation}(5)A common approach to the use of this equation is to approximate the beam with a pencil9 beam, BmodelBpencil, as adopted by HFI (Planck Collaboration VIII 2014) and WMAP (Jarosik et al. 2007). For LFI we have computed the full 4π beams for all detectors and we developed a fast convolution routine to estimate BmodelDref. This was motivated by the wish to fully control dipole-coupling to the sidelobes, particularly at 30 GHz where sidelobes are larger. The convolution of a generic beam with a dipole produces a smearing effect (due to the fact that not all the power is in the main beam) and a slight tilt in the dipole axis (resulting from asymmetries in the beam). As shown in detail in Sect. 4.2 and Appendix A, these effects can be quantified by the length and direction, respectively, of the vector S defined there.

We verified a posteriori that the net effect of the convolution does not produce a significant improvement over a pencil beam model at the present stage of the analysis (besides the tilt effect, which is <0.01%). For this data release, therefore, in the convolution routine we rescaled the length of vector S to unity, which is effectively equivalent to modelling the beam as a pencil beam. The advantage of this approach is that it matches the convention on the normalization of the beam that has been assumed in the calibration of HFI data. In the following description of map calibration and associated uncertainties, therefore, we assume BmodelBpencil. Full use of the 4π convolver, including integrated frequency-dependent sidelobes within the LFI radiometric bands, will be applied for later analyses, including polarization calibration.

thumbnail Fig. 3

Results of a simulation which shows how φD is computed. We assume to observe a 1 K peak-to-peak dipole in the sky for 5 minutes with a scanning strategy very similar to the one used for Planck’s 30 GHz radiometers, i.e., the sky is scanned in circles of high amplitude (~85°) with a rotation frequency ν = 1 / 60 Hz and a sampling frequency of 32.5 Hz (so that 10 000 temperature samples are generated for each data stream). We observe the dipole using a realistic 30 GHz beam B = Bmain + Bside with FWHM \hbox{$0\pdeg5$}. Panel A): plot of the (BmainD)(t) term, which oscillates as a sinusoid with amplitude ≲ 0.5 K; the term (BslD)(t) is negligible (see panel C for a close-up). Panel B): plot of the t(BmainD)(t) term, used in the definition of φD (Eq. (9)). Panel C): Close-up of the (BslD)(t) term shown in panel A). Panel D): close-up of the t(BslD)(t) shown in panel B). Panel E): value of φD as a function of time, calculated using the definition in Eq. 9. Panel F): distribution of the 10 000 values of φD plotted in panel E). Half of the values fall within the 0.19–0.34% range.

We can write the true beam B as the sum of two terms, B = Bmain + Bside, where Bmain represents the contribution of what we define as the main beam (defined as the portion of the beam within of the beam centre), and Bside represents the much smaller remaining part (the sidelobes). Equation (5) becomes: ˜GGt(BmainD+BsideD)t(BpencilDref)·\begin{equation} \tilde{G} \approx G \frac{\timeder\bigl(B_\mathrm{main}*D + B_\mathrm{side}*D\bigr)}{\timeder\bigl(B_\mathrm{pencil} * D_\mathrm{ref}\bigr)}\cdot \end{equation}(6)The convolution of the main beam with the signal from the sky, T = D + Tsky, is nearly identical to an ideal pencil beam except that only a fraction101 − fside of the antenna gain is contained in the main beam: BmainT(1fside)BpencilT(1fside)T.\begin{equation} B_\mathrm{main} * T \approx (1 - f_\mathrm{side}) B_\mathrm{pencil} * T \approx (1 - f_\mathrm{side}) T. \end{equation}(7)So we have: ˜G=G(1fside)t(BpencilD)+t(BsideD)t(BpencilDref)=G(1fside)(1+φD),\begin{eqnarray} \tilde{G} &=& G \frac{(1 - f_\mathrm{side}) \timeder\bigl(B_\mathrm{pencil}*D\bigr) + \timeder\bigl(B_\mathrm{side}*D\bigr)}{\timeder \bigl(B_\mathrm{pencil} * D_\mathrm{ref}\bigr)}\nonumber \\ &=& G (1 - f_\mathrm{side}) (1 + \phi_D), \end{eqnarray}(8)where φD=t(BsideD)t(BmainD)·\begin{equation} \label{eq:phiD} \phi_D = \frac{\timeder\bigl(B_\mathrm{side}*D\bigr)}{\timeder\bigl(B_\mathrm{main}*D\bigr)}\cdot \end{equation}(9)Figures 3 shows the result of a simulation which illustrates how φD can be computed from the TODs.

Consider now a properly calibrated timeline ˜Tsky\hbox{$\tilde{T}_\mathrm{sky}$} where the dipole and the monopole terms in Eq. (1) have been removed, so that ˜Tsky=G(BTsky)\hbox{$\tilde{T}_\mathrm{sky} = G (B * T_\mathrm{sky})$}. Within each pointing period of constant ˜G\hbox{$\tilde G$}, we can write the relationship between the measured sky temperature ˜Tsky\hbox{$\tilde{T}_\mathrm{sky}$} and the level of the true sky temperature11Tsky as: ˜Tsky(x(t))=G(BTsky)(x(t))˜G=(BTsky)(x(t))(1fside)(1+φD)·\begin{equation} \tilde{T}_\mathrm{sky} \bigl(\vec{x}(t)\bigr) = \frac{G \bigl (B * T_\mathrm{sky}\bigr)\bigl(\vec{x}(t)\bigr)}{\tilde{G}} = \frac{\bigl(B * T_\mathrm{sky}\bigr)\bigl(\vec{x}(t)\bigr)}{(1 - f_\mathrm{side})(1 + \phi_D)}\cdot \end{equation}(10)Solving for the true temperature Tsky, we find: Tsky˜Tsky(1φsky+φD),\begin{equation} \label{eq:skyMapCorrectedForSL} T_\mathrm{sky} \approx \tilde{T}_\mathrm{sky} (1 - \phi_\mathrm{sky} + \phi_D), \end{equation}(11)where φsky=BsideTskyBmainTsky(Tsky˜Tsky)\begin{equation} \phi_\mathrm{sky} = \frac{B_\mathrm{side} * T_\mathrm{sky}}{B_\mathrm{main} * T_\mathrm{sky}} \left(\frac{T_\mathrm{sky}}{\tilde{T}_\mathrm{sky}}\right) \end{equation}(12)is a time-dependent quantity which quantifies how much of the sky signal enters the beam through its sidelobes.

thumbnail Fig. 4

Estimated value of φD averaged over the first and second surveys. The central frequencies of the radiometers are 70 GHz for 18M...23S, 44 GHz for 24M...26S, and 30 GHz for 27M...28M. In order to reduce the amount of data to consider, the time-dependent quantity φD was projected on a Healpix map (with NSIDE equal to 64) and binned. The error bars represent the first and third quartiles of the values of the 49 152 pixels in the map, while the middle point is the median.

A precise evaluation of the correction terms φD and φsky in Eq. (11) requires detailed simulations. We have performed such calculations for φD by computing the convolution of the sidelobes with the dipole from sample GRASP full beams, leading to φD ≈ 0.15% (see Fig. 4). The term φsky requires a full convolution of a sky model with the full beam, and it is frequency dependent. We performed a simulation for a 70 GHz channel, projected the values of φsky on a map and found values ranging between 0.05% to 0.2% throughout a full survey. In conclusion, the correction terms φsky and φD are of the same order, within 0.2%, and they tend to cancel out in Eq. (11). Given that the relative uncertainties on both terms are large, we do not correct for them in the data and estimate a residual uncertainty of 0.2% in the gain. This uncertainty is included in our overall estimated calibration uncertainty.

2.3. Colour corrections

Table 1

Multiplicative colour corrections \hbox{$\cc(\alpha)$} for individual LFI radiometer chain assemblies and for the band average maps.

The raw differential signal V = VskyrVref measured by a Planck radiometer can be written as: V=Gg(ν)TRJ(ν)dν=G2kBg(ν)I(ν)λ2dν=\begin{eqnarray} V &=& G \int g(\nu) T_{\rm RJ}(\nu)\, \ud\nu = \frac{G}{2k_B} \int g(\nu) I(\nu) \lambda^2 \,\ud\nu \nonumber\\ &=& G' \int \tau(\nu) I(\nu) \,\ud\nu, \label{eq:raw_voltage} \end{eqnarray}(13)where G is the overall gain, g(ν) is the bandpass, TRJ(ν) is the differential Rayleigh-Jeans brightness temperature averaged over the beam, and G is defined such that 2kBGτ(ν) = Gg(ν)λ2. The constant G would be the gain if bandpasses were defined via the transmission coefficient τ(ν) ∝ g(ν)λ2 instead of g(ν), as HFI does (Planck Collaboration VIII 2014).

Since we calibrate using the CMB dipole, the calibration signal measured in any given pointing period is: DK=Gg(ν)DηΔT(ν)dν,\begin{equation} \label{eq:colourCorrectionDoverK} \frac{D}{K} = G \int g(\nu) D\, \eta_{\Delta T}(\nu) \,\ud\nu, \end{equation}(14)where D is the dipole amplitude in thermodynamic units and ηΔT(ν) is the conversion factor from CMB temperature to RJ temperature. Hence the calibrated sky map temperature is: ˜T=KV=g(ν)TRJ(ν)dνg(ν)ηΔT(ν)dν·\begin{equation} \tilde{T} = K V = \frac{\int g(\nu) T_{\rm RJ}(\nu)\, \ud\nu}{\int g(\nu) \eta_{\Delta T}(\nu)\, \ud\nu}\cdot \label{eq:T_calibrated} \end{equation}(15)If we are observing pure CMB fluctuations, then TRJ(ν) = ΔTηΔT(ν), and hence we have ˜T=ΔT\hbox{$\tilde{T} = \Delta T$} as expected. If we are observing foreground emission with intensity power-law index α, then TRJ(ν) = T0 (ν/ν0)α − 2, and ˜T=T0g(ν)(ν/ν0)α2dνg(ν)ηΔT(ν)dν·\begin{equation} \tilde{T} = T_0 \frac{\int g(\nu) (\nu/\nu_0)^{\alpha-2} \, \ud\nu}{\int g(\nu) \eta_{\Delta T}(\nu)\, \ud\nu}\cdot \end{equation}(16)The LFI colour correction is defined as: 𝒞(α)=g(ν)ηΔT(ν)dνηΔT(ν0)g(ν)(ν/ν0)α2dν·\begin{equation} \cc(\alpha) = \frac{\int g(\nu) \eta_{\Delta T}(\nu)\, \ud\nu}{\eta_{\Delta T}(\nu_0) \int g(\nu) (\nu/\nu_0)^{\alpha-2} \, \ud\nu}\cdot \label{eq:cc} \end{equation}(17)Hence the colour-corrected temperature is: 𝒞(α)˜T=T0/ηΔT(ν0).\begin{equation} \cc(\alpha)\tilde{T} = T_0 / \eta_{\Delta T}(\nu_0). \label{eq:correctedKCMB} \end{equation}(18)This gives the thermodynamic brightness differential temperature (units “KCMB”) at the reference frequency ν0. To get to the standard (Rayleigh-Jeans) brightness temperature at the same frequency we use ηΔT(ν0) (see Eq. (14)): T0[KRJ]=˜T[KCMB]ηΔT(ν0)𝒞(α).\begin{equation} T_0 [{\rm K_{\rm RJ}}] = \tilde{T} [{\rm K_{\rm CMB}}] \, \eta_{\Delta T}(\nu_0) \, \cc(\alpha). \end{equation}(19)For the present series of Planck papers, the reference frequencies ν0 are defined as precisely 28.4, 44.1, and 70.4 GHz for the three LFI bands; in the Planck Early Release papers, slightly different values were used.

Values for \hbox{$\cc(\alpha)$} for the expected range of foreground spectral indices are listed in Table 1. Note that this definition of \hbox{$\cc$} is inverted relative to the colour correction \hbox{$\cc_\text{ER}(\alpha)$} used in the Planck Early Release. We note additionally that \hbox{$\cc(\alpha)$} quoted here are not exactly equal to \hbox{$1/\cc_\text{ER}(\alpha)$} from Mennella et al. (2011) and Zacchei et al. (2011), due both to the change in reference frequency and also to a small error in the earlier estimates.

Colour corrections at intermediate spectral indices may be derived accurately from a quadratic fit to the values in Table 1. In addition, the data release includes the Unit conversion and Colour Correction (UcCC) IDL package (Planck Collaboration IX 2014) which calculates colour corrections and unit conversions using the band-averaged bandpass information stored in the Reduced Instrument MOdel (RIMO, see Planck Collaboration 2013) file also included in the data release.

From Eq. (17) it appears that the absolute scaling of the bandpass is irrelevant for the colour correction, although Eqs. (13)–(15) require that: g(ν)ηΔT(ν)dν=1,\begin{equation} \int g(\nu)\,\eta_{\Delta T}(\nu)\,\ud\nu = 1, \label{eq:bp_norm} \end{equation}(20)for consistency with the definition of gain, G, and calibration factor, K, elsewhere in this paper. In practice, all the colour corrections listed in Table 1 are derived from averages across two or more bandpasses: values for individual radiometric chain assemblies (RCA) require averaging the main and side radiometers in each RCA, and the response of each radiometer is the average of the two independent detectors (Zonca et al. 2009). For consistency, the weighting for these averages must duplicate the procedure used to average the data, as described in Planck Collaboration II (2014). We recall here the procedure: (i) calibrate the individual data streams to give equal response to the CMB; (ii) combine the raw data for the detectors for each radiometer using fixed weights based on the inverse variance measured early in the mission, incorporating fixed calibration values; (iii) recalibrate the data using time-dependent factors as described in the present paper; (iv) combine the two radiometers in each RCA with equal weights to minimize polarization leakage; and (v) combine the data from individual RCAs with inverse-variance weights (fixed for the whole mission). When combining the bandpasses, the initial calibration step is equivalent to normalizing each component bandpass according to Eq. (20). The band-averaged bandpass stored in the RIMO, however, normalized the bandpasses using g(ν) dν = 1. The difference is minor, since ηΔT varies by only a very small amount within any of the LFI bands, but it accounts for a small (<0.1%) difference between the \hbox{$\cc(\alpha)$} values listed here and those derivable from the RIMO bandpasses.

Our best estimate of the uncertainty in the values of \hbox{$\cc(\alpha)$}, dominated by bandpass uncertainty (Zonca et al. 2009), comes from an indirect method, as follows. The two radiometers in each RCA, known as the main- and side-arms, are sensitive to orthogonal polarizations. The bandpasses for the two arms differ, leading to different colour corrections. The polarization signal is derived from the difference of the calibrated signals from the two arms (Leahy et al. 2010); unpolarized foreground emission does not precisely cancel due to the diffential colour factors. This is the “bandpass leakage” effect. This leakage can be estimated from the flight data, as described by Planck Collaboration II (2014), but it can also be estimated from the pre-launch bandpass models that we use here to calculate \hbox{$\cc(\alpha)$}. To a good approximation, we can write the leakage factor as (𝒞S(α)𝒞M(α))/2=(ββCMB)a,\begin{equation} \left(\cc_\mathrm{S}(\alpha) - \cc_\mathrm{M}(\alpha)\right)/2 = (\beta-\beta_\mathrm{CMB})\,a, \end{equation}(21)where the a-factors depend solely on the bandpass profile, β = α − 2 is the temperature spectral index, and βCMB is the in-band spectral index of the CMB, which we can take as zero for present purposes. The flight measurements of the a-factors are demonstrably more accurate than the pre-launch (“QUCS”) estimates, and so (ββCMB)(aQUCSaflight)(δ𝒞S(α)δ𝒞M(α))/2,\begin{equation} (\beta- \beta_\mathrm{CMB})(a_\mathrm{QUCS} - a_\mathrm{flight}) \approx (\delta \cc_\mathrm{S}(\alpha) - \delta \cc_\mathrm{M}(\alpha))/2, \end{equation}(22)where \hbox{$\delta \cc$} is the colour correction error. Statistically (δ𝒞S(α)δ𝒞M(α))2=(δ𝒞S(α)+δ𝒞M(α))2=σ𝒞2,\begin{equation} \left<\left(\delta \cc_\mathrm{S}(\alpha) - \delta \cc_\mathrm{M}(\alpha)\right)^2\right> = \left<\left(\delta \cc_\mathrm{S}(\alpha) + \delta \cc_\mathrm{M}(\alpha)\right)^2\right> = \sigma_\cc^2, \end{equation}(23)where \hbox{$\sigma_\cc$} is the colour correction error for one radiometer pair, i.e. one RCA. Hence for individual RCAs, \hbox{$\sigma_\cc \approx |\beta|\,\sigma_a$}. There are too few pairs for this approach to give an accurate value for \hbox{$\sigma_\cc$}, especially as the error sources for the bandpasses in each band are different; therefore results from the three bands cannot be combined. Our rough estimates for σa are 0.14%, 0.46%, and 0.51% in the 30, 44, and 70 GHz bands, respectively. For the band-averaged maps, the errors in the colour corrections are reduced by NRCA\hbox{$\sqrt{N_\mathrm{RCA}}$}, giving overall rough uncertainties of 0.1 | β |, %, 0.3 | β |%, and 0.2 | β |%, respectively. Given typical values of β of around −2 to −3, this gives uncertainties in the colour corrections of a few tenths of a percent of the tabulated value at 30 GHz, and 0.5–1% at 44 and 70 GHz.

Progress towards in-flight calibration of the colour corrections is discussed further in Sect. 5.4.1.

3. Calibration techniques for LFI

thumbnail Fig. 5

Variation in time of a few quantities relevant for calibration, for radiometer LFI21M (70 GHz, left) and LFI27M (30 GHz, right). Vertical dashed lines mark boundaries between complete sky surveys. All temperatures are thermodynamic. Panel A): calibration constant K estimated using the expected amplitude of the CMB dipole. Note that the uncertainty associated with the estimate changes with time, according to the amplitude of the dipole as seen in each ring. Panel B): expected peak-to-peak difference of the dipole signal. The shape of the curve depends on the scanning strategy of Planck (see also Fig. 8), and it is strongly correlated with the uncertainty in the gain constant (see panel A)). The two dots indicate at which time the data used to produce the plots in Fig. 9 were taken. Panel C): 4 K total-power output voltages V. Note that the noise level for V is much more stable than it is for K, as it does not depend on the dipole amplitude. (All the large jumps seen in this figure occurred because of some change in the operational state of the spacecraft; e.g., 456 days after launch we switched off the primary 20 K sorption cooler and turned on the redundant unit.) Panel D): The calibration constants K used to actually calibrate the data for this Planck data release are either derived by applying a smoothing filter to the raw gains in panel A) (70 and 44 GHz, e.g., LFI21M, left), as described in Sect. 3.1, or through Eq. (32) and the 4 K total-power voltages in panel C (30 GHz, e.g., LFI27M, right).

There is not a unique way to produce an estimate of the calibration constant K = G-1 (see Eq. (1)). In picking the method to use, one has to consider a number of elements:

  • 1.

    the calibration should be as accurate as possible;

  • 2.

    calibrated data should also be self-consistent; for example, with the same beam and the same pointing direction and orientation in the sky, the value of Tsky at any frequency should not depend on when the measurement was done, nor on the detector (under the hypothesis that everything else, e.g., the bandpass, can be assumed to be the same);

  • 3.

    the estimated shape of K(t) should be motivated by a physically meaningful model of the radiometer.

To help in the classification of the calibration methods discussed in this work, we write: K(t)=K0(1+ξ(t)),\begin{equation} \label{eq:KKzeroAndXi} K (t) = K_0 \bigl( 1 + \xi(t) \bigr), \end{equation}(24)thus decomposing K into a constant term K0 and a unitless time-varying quantity ξ(t). Typically ξ(t) varies by a few percent per year. This allows us to categorize calibration methods into the following families: (1) absolute methods produce an estimate for K0; (2) relative methods estimate how ξ changes with time; and (3) some methods are able to estimate K(t) directly and can therefore be considered both absolute and relative.

thumbnail Fig. 6

Schematics of a LFI radiometer. The radiation entering the feed horns in the 20 K front end is split by an OrthoMode transducer (OMT) into its two linearly polarized components. The two signals feed two twin radiometers. (Only one of them is shown in this figure.) The 2.7 K signal is mixed with the signal emitted by a reference blackbody at 4.5 K by an hybrid coupler before being amplified by a Low Noise Amplifier (LNA). A 4096 Hz phase switch induces an alternating 0°/180° phase shift, so that the outputs of the second hybrid are two sequences of sky/reference signals, which both propagate to the warm back-end. Here they are further amplified and measured, before being compressed into packets and sent to Earth. Refer to Mennella et al. (2010) for more details.

We implemented two calibration schemes for the LFI radiometers:

  • The OSG dipole calibration is an improved version of the pipelineused to calibrate the data used in the Planck Early andIntermediate data releases (Mennellaet al. 2011). It is based on the OSGalgorithm (“Optimal Search for Gains”) and relies on the signal ofthe solar and orbital dipoles as observed by the spacecraft. Thismethod is only weakly affected by non-idealities in theradiometers (e.g., non-linearities in the ADCs, seeSect. 4.3), but optical effects (e.g., sidelobes, seeSect. 4.1) can induce systematic errors in thereconstruction of the gain.

  • In the 4 K calibration we use the dipole only to fix the absolute level of calibration (K0 in Eq. (24)), but we estimate gain changes (the ξ term) using the 4 K total-power output of the radiometers. (See Fig. 6 for a schematic of a LFI radiometer.) Unlike the OSG dipole calibration, this scheme is sensitive to ADC non-linearities, but it provides an estimate for the gain, K, which is independent12 of optical effects, assuming that the optical properties remain constant. (As Fig. 4 in Planck Collaboration IV (2014) shows, measurements of the main beam characteristics from planet transits during the whole Planck nominal mission show no trace of systematic variations with time.)

The chief reason why we decided to use two different calibration schemes was to improve the self-consistency of the maps. We were not able to derive a calibration method that was robust against both radiometric non-idealities and optical effects in time for this data release. Since optical effects are most significant in the 30 GHz channels, we decided to apply the 4 K calibration to these radiometers instead of the other one (which was the baseline for the Early and Intermediate Planck/LFI papers). We provide a summary of the calibration methods used for each LFI frequency in Table 2. In Sect. 4.1 we discuss the level of consistency between the two calibration methods in the context of the treatment of optical systematics.

The outline of this section is as follows. The OSG dipole calibration and the 4 K calibration are explained in Sects. 3.1 and 3.2. In Sect. 3.3 we present the current status of our efforts to use the orbital dipole signal for calibrating data. Finally, Sect. 3.4 deals with the task of setting the zero-level of Planck’s LFI maps.

Table 2

Methods used to calibrate the radiometers.

3.1. OSG dipole calibration

The combination of the motions of the spacecraft, the Earth, and the solar system with respect to the CMB produce a dipole signal with an amplitude of (3.355 ± 0.008) mK (Hinshaw et al. 2009) on the full sky. Like COBE (Kogut et al. 1996) and WMAP (Jarosik et al. 2011), we use this signal to estimate the value of K = G-1 in Eq. (1). We indicate the gain estimates produced using this method with Kdip. To avoid the contamination of the dipole signal with residual Galactic emission, we employ a iterative technique that removes this sky signal from the calibration process.

Table 3

Parameters used in the model of the dipole signal.

thumbnail Fig. 7

Mask used in the application of Eq. 27 to 30 GHz data (Ecliptic coordinates). The mask hides point sources and the strong emission of the Galactic plane. What is left is that part of the sky where the only significant emissions are the CMB dipole and the CMB itself. Similar masks have been used for 44 and 70 GHz data.

The basic steps of this calibration procedure are as follows:

  • 1.

    We combine the velocity of the spacecraft with respect to theSun vPlanck and the velocity of the Sun with respect to the CMB vSun to estimate the amplitude and alignment of the dipole in the sky in a given direction x: D(x,t)=TCMB(1γ(t)(1β(t)·x)1),\begin{equation} \label{eq:dipole:fundamental} D(\xversor, t) = T_\mathrm{CMB}\left(\frac1{\gamma(t)\,\bigl(1 - \vec{\beta}(t)\cdot \xversor\bigr)} - 1\right), \end{equation}(25)where TCMB is the temperature of the CMB monopole, β = (vSun + vPlanck) /c, γ = (1 − β2)− 1 / 2, vSun is the velocity of the solar system with respect to the CMB rest frame, and vPlanck is the spacecraft’s velocity with respect to the solar system’s barycentre. Table 3 reports the numerical values used in the pipeline.

  • 2.

    We produce discrete time-ordered data (TOD) of the expected overall dipole signal (thermodynamic temperature) at time ti: Di=D(x(ti),ti),\begin{equation} D_i = D\bigl(\xversor (t_i), t_i\bigr), \end{equation}(26)where i ranges from 1 to N ~ 105 (the number of samples in a pointing period). As we explained in Sect. 2.2, the computation of the expected dipole signal takes the shape of the beams into account, following a method described in Sect. 4.2.

  • 3.

    Using pointing information, we project both Vi (the voltage V at time i, as used in Eq. (1)) and Di on a HEALPix map (Górski et al. 2005) with Nside = 256. Multiple hits on the same pixels are averaged in both cases. The result is a pair of maps, Vkmap\hbox{$V^\text{map}_k$} and Dkmap\hbox{$D^\text{map}_k$}, with k being the pixel index13.

  • 4.

    We use weighted least squares to estimate K in Eq. (1) from the correlation between the signal in volt Vkmap\hbox{$V^\text{map}_k$} with Dkmap\hbox{$D^\text{map}_k$}: Vkmap=KdipDkmap+ϵ,\begin{equation} \label{eq:dipoleFit} V^\text{map}_k = K_\text{dip}\,D^\text{map}_k + \epsilon, \end{equation}(27)where Kdip and ϵ are the parameters used in the fit. Each sample k is weighted according to the number of hits per pixel. In computing the fit, we use a frequency-dependent mask to avoid those pixels where a strong non-Gaussian signal other than the dipole is expected. Such masks are the union of a Galactic mask (CG80, see Planck Collaboration XII 2014) and a point source mask (conceptually similar to the point source masks used in component separation, but the masking radius is kept fixed at 32 ). See Fig. 7 for an example (30 GHz). In Sect. 5.3.1 we explore the effect of changing the mask on the calibration.

  • 5.

    The fit described in the previous step suffers from the presence of noise in the sky signal, Vmap (mainly due to the CMB and to Galactic emission that was not properly masked). Therefore we apply an iterative algorithm, named Mademoiselle, that uses destriping techniques to iteratively improve the calibration. The algorithm subtracts the convolution between the dipole signal and the 4π beam from Vmap, thus obtaining a set of maps (one per each pointing period m) which estimate the sky signal alone, Tsky: Tksky=(VkmapKdipDkmapϵ)Kdip,\begin{equation} T^\text{sky}_k = \bigl( V^\text{map}_k - K_\text{dip} D^\text{map}_k - \epsilon\bigr) K_{\text{dip}}, \end{equation}(28)with k being the pixel index. (Here again each map covers only a tiny fraction of the whole sky, i.e., the circle covered during each pointing period.) We apply a destriping algorithm to the set of m maps of Tsky and use the result to apply a correction to Kdip and ϵ. We iterate this process until a convergence criterion is satisfied. The result of Mademoiselle is a new set of gains, Ki (again, one per pointing period), and offsets, ϵi. See also the section about TOD processing in the Planck explanatory supplement (Planck Collaboration 2013).

  • 6.

    The gains produced by this procedure need to be further processed in order to reduce the statistical noise. We applied an adaptive smoothing filter based on wavelets, which smooths more around dipole minima and less around maxima (see Planck Collaboration II 2014). In those cases where the noise is too high for the filter to produce meaningful results (i.e., near dipole minima), we substituted the gains with a straight line. This can be seen in the left panel D of Fig. 5, near 100, 300, and 500 days after launch.

  • 7.

    Once a set of Ki gains (one per pointing period) is produced, the pipeline calibrates the timelines and subtracts the dipole signal, so that in the calibrated timestreams the Galactic signal and the CMB fluctuations are the only relevant astrophysical components.

Details of the code implementation are given in Planck Collaboration II (2014).

thumbnail Fig. 8

Top: dipole signal due to the motion of the solar system only (in Ecliptic coordinates). The points observed by LFI27M during pointing periods 4800 (250 days after launch) and 6636 (300 days) are shown with black and blue lines, respectively. (In Fig. 5, panel B on the right, we indicate the times when these two periods occurred with black dots.) Bottom: dipole signal along the same two pointing periods as a function of the North phase angle. Note the difference in the amplitude of the two sinusoidal waves. Such differences are due to the Planck’s scanning strategy and determine the statistical error in the estimation of the calibration constant K = G-1 (Eq. (1)). Refer also to Fig. 9 for details about how K is computed for these two pointing periods.

thumbnail Fig. 9

The iterative calibration procedure fits the differential voltages with the expected dipolar signal (KCMB), both projected on a map, and it calculates the gain according to Eq. (27). As Fig. 8 shows, depending on the position of the circle with respect to the axis of the dipole signal, the range spanned by the signal can be either large (dipole maximum, top) or small (dipole minimum, bottom). Of course, in the latter case the estimation of the gain suffers from a larger statistical error.

The accuracy in gain reconstruction depends critically on the orientation of the spacecraft with respect to the dipole axis, i.e. the value of the product (vSun + vPlanckx. We speak of a dipole minimum when the spacecraft’s orientation is such that the value of the scalar product reaches a minimum, and a dipole maximum when reaches a maximum. Figure 5 shows this idea for two LFI radiometers, LFI21M (left) and LFI27M (right): in panel A we show the values of Kdip as a function of time, while in panel B we show the expected amplitude of the dipole ΔTdip as seen in the circle in the sky (ring) which is scanned during each pointing period. It is clear that the noise in Kdip is mainly due to the variation of ΔTdip. The reason why the peak-to-peak difference of the measured dipole signal varies is represented in Fig. 8, which shows which parts of the sky are observed by LFI27M during two pointing periods, one (4800) near a dipole maximum, and another (6636) near a dipole minimum. Finally, Fig. 9 shows the data used to compute the weighted linear regression presented in item 4 above for the same pointing periods.

3.2. 4 K calibration

Gain changes in a LFI radiometer can be modelled using the emission of the internal 4 K reference load as measured by the radiometer itself (Valenziano et al. 2009).

We indicate with Vref the output voltage which measures the temperature of the 4 K reference load. Equation (1) changes via the transformation B ∗ (Tsky + D) → Tref: Vref=G(Tref+Tnoise+ϵiso(BTsky+D+Tnoisesky))=G(Tref+Tnoise+ϵisoΣsky),\begin{eqnarray} V_\mathrm{ref} &=& G\Bigl(T_\mathrm{ref} + T_\mathrm{noise} + \epsilon_\mathrm{iso} \bigl(B * T_\mathrm{sky} + D + T^\mathrm{sky}_\mathrm{noise})\Bigr) \nonumber\\ &=& G\Bigl(T_\mathrm{ref} + T_\mathrm{noise} + \epsilon_\mathrm{iso} \Sigma_\mathrm{sky}\bigr), \end{eqnarray}(29)where the term Tnoise is analogous to the monopole term M in Eq. (1), and we include a possible leakage from the sky signal Σsky=BTsky+D+Tnoisesky\hbox{$\Sigma_\mathrm{sky} = B * T_\mathrm{sky} + D + T^\mathrm{sky}_\mathrm{noise}$} (the term Tnoisesky\hbox{$T^\mathrm{sky}_\mathrm{noise}$} represents the noise temperature associated with the measurement of the sky signal). Solving for K = G-1 yields a formula that can be used to estimate K from the ratio between the sum of temperatures and the 4 K reference voltage: K4K(t)=Tref+ϵisoΣsky+TnoiseVrefTtotVref,\begin{equation} \label{eq:kFordVV} K_{4\,\mathrm{K}}(t) = \frac{T_\mathrm{ref} + \epsilon_\mathrm{iso} \Sigma_\mathrm{sky} + T_\mathrm{noise}}{V_\mathrm{ref}} \equiv \frac{T_\mathrm{tot}}{V_\mathrm{ref}}, \end{equation}(30)where ϵiso is the isolation (for its definition see Villa et al. 2010) and the term ϵisoΣsky represents the amount of signal coming from the sky and leaking into the reference load signal. We express the term Vref-1\hbox{$V_\mathrm{ref}^{-1}$} as: Vref-1=Vref,0-1(1+VrefVref,0Vref,0)-1Vref,0-1(1VrefVref,0Vref,0)=Vref,0-1(2VrefVref,0),\begin{eqnarray} \label{eq:voltageFirstOrderExpansion} V_\mathrm{ref}^{-1}&=&V_\mathrm{ref,0}^{-1}\left(1+\frac{V_\mathrm{ref}-V_\mathrm{ref,0}}{V_\mathrm{ref,0}}\right)^{-1} \notag\\ &\approx& V_\mathrm{ref,0}^{-1}\left(1 - \frac{V_\mathrm{ref}-V_\mathrm{ref,0}}{V_\mathrm{ref,0}}\right) \notag\\ &=& V_\mathrm{ref,0}^{-1}\left(2 - \frac{V_\mathrm{ref}}{V_\mathrm{ref,0}}\right), \end{eqnarray}(31)where we applied a first-order Taylor expansion14 for Vref around the value Vref,0. We substitute it into Eq. (30) to derive the following equation: K4K(t)Tref,0+ϵisoΣsky,0+Tnoise,0Vref,0(2Vref(t)Vref,0)·\begin{equation} \label{eq:gainAsFunctionOfV} K_{\mathrm{4\,K}}(t) \approx \frac{T_\mathrm{ref,0} + \epsilon_\mathrm{iso} \Sigma_\mathrm{sky,0} + T_\mathrm{noise,0}}{V_\mathrm{ref,0}} \left( 2 - \frac{V_\mathrm{ref}(t)}{V_\mathrm{ref,0}}\right)\cdot \end{equation}(32)(Ideally, variations in Tref, in ϵisoTref, and in Tnoise should be negligible; we quantify their variation later.) In principle, Eq. (32) would be enough to estimate K at any time, if one knew all the terms in the right side of the equation with the desired accuracy (e.g., 0.1%). Since this is not our case, to find the unknown factor in the equation we use the estimate of K(t) from the dipole (see Sect. 3.1) to perform a weighted linear least squares from which we estimate K0: Kdip(t)=K0×(2Vref(t)Vref,0)·\begin{equation} K_\mathrm{dip}(t) = K_0 \times \left( 2 - \frac{V_\mathrm{ref}(t)}{V_\mathrm{ref,0}}\right)\cdot \end{equation}(33)(Note that here we use the “raw” values for Kdip(t), i.e., before applying the smoothing filter described in Sect. 3.1, point 6.) The average value15 of Vref(t) over the whole set of data to be calibrated is used for Vref,0, and the weights wi in the linear squares fit are proportional to the amplitude of the dipole signal ΔTdip seen by the radiometer during the i-th pointing, that is, wi ∝ ΔTdip. According to our classification based on Eq. (24), this calibration scheme is relative (with ξ(t) = (Vref,0Vref(t)) /Vref,0) but not absolute, as we need Kdip(t) in order to estimate K0.

As an example, see Fig. 5, panel D (right), which shows the values of K4 K calculated for LFI27M (a 30 GHz radiometer). Unlike the case for LFI21M (panel D, left), which required a smoothing filter to be applied to the raw gains in panel A, here we use the total-power voltages without any filtering, as their error does not depend on the amplitude of the observed dipole in the sky, but only on the stability of the 4 K reference load, which is better by orders of magnitude.

thumbnail Fig. 10

Variation of the temperature of the back-end with time, as measured by sensor LM207332 (placed near the back-end amplifiers of LFI27M and 27S). The two major thermal events that happened during the period of the nominal mission are clearly visible here: (1) 258 days after launch the transponder antenna switched from a on/off duty cycle of 24 h to being always kept on, and (2) 456 days after launch we switched to the other sorption cooler used to cool the focal plane.

When we presented Eq. (32), we began with the assumption that variations in time of the three terms Tref, ϵisoΣsky, and Tnoise were negligible, in order not to induce significant systematic effects in the determination of the gain. We now quantify how much they are expected to change during the mission. (Refer to Sect. 2.1 for a general discussion of time scales and LFI calibration.) If we write Vref(t) − Vref,0 as δVref, and similarly for δTref, δΣsky, δTnoise, and δK, from Eq. (32) we derive the following expression: δK(t)K0=δVrefVref,0+δTref+ϵisoδΣsky+δTnoiseTtot,0,\begin{equation} \frac{\delta K(t)}{K_0} = -\frac{\delta V_\mathrm{ref}}{V_\mathrm{ref,0}} + \frac{\delta T_\mathrm{ref} + \epsilon_\mathrm{iso}\,\delta \Sigma_\mathrm{sky} + \delta T_\mathrm{noise}}{T_\mathrm{tot,0}}, \end{equation}(34)with Ttot,0 = Tref,0 + ϵisoTsky,0 + Tnoise,0 ≈ 20 K for the LFI 30 GHz radiometers. This equation expresses fluctuations in K in terms of fluctuations in Vref and the three terms in the numerator of the second fraction on the right side, whose sum should be much smaller than Ttot,0. In the case of LFI’s 30 GHz radiometers, the following considerations apply:

  • 1.

    The variation of Tref during Planck’s nominal mission is of the order of a few mK, therefore making the term δTref/Ttot,0 negligible (hourly variations are of the order of 0.1 mK).

  • 2.

    The value of ϵiso is generally less than 0.1 (Villa et al. 2010). The biggest contribution to δΣsky comes from the solar dipole D (maxδD ≈ 3.5 mK). Such variations have an impact of only about 0.01% on K4 K.

  • 3.

    For δTnoise/Ttot,0 the approximation is not so good, because of the dependence of Tnoise on the temperature of the focal plane (Terenzi et al. 2009). Two events triggered significant changes in the satellite thermal environment. Firstly, starting 258 days after launch, the transponder of the communication system was always kept on, instead of being switched on just for transmission, in order to increase thermal stability. Secondly, 456 days after launch, the first sorption cooler reached its end-of-life and the second sorption cooler was switched on (see Fig. 10). These major changes of the thermal environment are expected to have an impact on Tnoise of 0.51%. This cannot be considered negligible and has to be corrected for.

The simplest correction strategy for this last effect would be to apply the 4 K calibration model separately for each section of the data. However, this technique is more subject to the systematic effects known to affect the dipole calibration. Therefore a more robust approach is to create a map of each section independently, removing both the cosmological and orbital dipoles, then fit for a residual dipole while masking the Galactic emission, and finally estimate the correction factor ξ4 K as: ξ4K(i)=1ΔTfit(i)ΔTsky,\begin{equation} \xi_\mathrm{4\,K} (i) = 1 - \frac{\Delta T_\mathrm{fit}(i)}{\Delta T_\mathrm{sky}}, \end{equation}(35)where ΔTfit(i) is the dipole fitted on each section i and ΔTsky is the cosmological dipole. For example, if the residual dipole is 0.1% of the cosmological dipole, it means we are over-calibrating by 0.1%, so we need to correct the calibration by that factor. Table 4 lists the residual dipole values and the corrections applied.

Table 4

Dipole residuals and correction factors applied to the 4 K calibration at 30 GHz in response to major thermal events.

3.3. Orbital dipole calibration

The CMB dipole induced by the peculiar velocity of the solar system relative to the CMB last scattering surface is a superb tool for LFI calibration, thanks to its high S/N source for all the frequency channels of LFI. Unfortunately it is not a fundamental cosmological parameter and has no predicted amplitude and direction: therefore, it must be calibrated against something else which is known absolutely. The relative velocity of the Planck satellite with respect to the solar system barycentre is known very precisely and adds a further dipole signal with a known amplitude and direction to the data. As the satellite is located at L2, its velocity relative to the CMB rest frame is dominated by the Earth’s motion around the Sun and ranges between 29.6 km s-1 and 30.6 km s-1, and the amplitude of the induced dipole signal is around 250  μK. This is an order of magnitude smaller than the cosmological dipole, and it is too weak to use on a pointing-by-pointing basis. Therefore, some form of relative calibration must be used to tie together data from each pointing period.

For the WMAP radiometers, passively-cooled to 100K, in the 5-year and 7-year analyses (Hinshaw et al. 2009; Jarosik et al. 2011) an adequate solution for relative calibration was obtained using a simple parametrized fit based on detector voltages and hot and cold stage temperatures. For the LFI radiometers, which are cryogenically cooled to 20 K and use blackbody reference loads cooled to 4 K, a more complex thermal model is needed for a high precision parametric solution based on housekeeping information. In this analysis, the approximate method described in Sect. 3.2 is implemented, together with the OSG approach reported in Sect. 3.1.

Our starting point for using the orbital dipole is the time-ordered-data, since the direction of the induced dipole is in the direction the satellite is traveling, and it is therefore time-dependent. Furthermore, one must use TODs which have not been processed with the calibration module, since that module removes both dipoles from the data. As most of the pixels on the sky are observed with two observations separated by approximately six months, where the velocity is in opposite directions, the orbital dipole signal cancels out to first order on the full mission sky maps. The time-ordered data are binned into rings for each pointing period, based on the rotation phase angle of the satellite. In this way all the relevant information is stored in a more compact and accessible form, with the advantage that the orbital dipole appears as a near sinusoid variation with the same phase in each ring.

A good relative calibration is required to remove the gain differences the between rings. For this we use the gains used in the final analysis as these are the best available. For the 70 and 44 GHz channels this may appear to be potentially circular as they are already calibrated on the solar dipole, but tests introducing a scaling factor into the relative gains shows that the same factor is recovered in the absolute gain. In this way any tension between the WMAP dipole used in the calibration and the orbital dipole would be revealed as a non-unity correction factor.

Both solar and orbital dipoles can then be fitted in the timeline, with the direction and amplitude of the solar dipole left free and the amplitude of the orbital dipole providing the final calibration. Currently, uncertainties in the ring-to-ring relative calibration and far-sidelobes limit the accuracy of this calibration to 0.26%,0.16% and 0.64% at 70, 44 and 30 GHz, respectively, based on variations in the results. As this does not offer a significant improvement over the WMAP dipole, this analysis has therefore been postponed to a subsequent release of the LFI data when the characterization of far sidelobes and gain variations is more mature. Table 5 reports the results of a preliminary analysis of correction factors and solar dipole parameters for the 44 GHz channels (where the effect of far-sidelobes is least).

Table 5

Preliminary estimates of the CMB dipole in the 44 GHz channels.

3.4. Setting the zero levels in the maps

The monopole of Planck maps is unconstrained: adding a constant to the time-ordered data leaves the likelihood of the map unchanged. It is therefore conventional to adjust the monopole of the maps in order to attain plausible absolute values of the high Galactic latitude diffuse Galactic foreground signal, and plausible values of the frequency scaling of this Galactic signal from channel to channel.

For LFI we have implemented two different approaches to evaluate the zero level. The first considers a circular region of sky centred on \hbox{$(l, b) = (344\pdeg47, -77\pdeg08)$} with radius of one degree16, on which the monopole matching is performed. We subtracted the estimated contribution of the CMB (smoothed to the angular resolution of each channel) from each LFI frequency map prior to matching diffuse foreground amplitudes. The average value of the CMB-subtracted pixels within the above mask is adjusted to match following values: 35  μKat 30 GHz, 15  μKat 44 GHz, and 18  μKat 70 GHz.

The other approach we implemented is similar to the one adopted by WMAP and described by Bennett et al. (2003, 2013). The procedure is the following: (1) we smooth the maps at angular resolution; (2) we subtract the estimated CMB signal, again smoothed at the common resolution; and (3) we fit the observed variation with Galactic latitude assuming a plane-parallel model for the Galactic emission. We consider only the behaviour on the southern hemisphere (in the range −90°<b< − 15°) in order to avoid possible contamination from the high-galactic latitude structures present in the Galactic emission such as the North Polar Spur. We divide the map into stripes of constant latitude 2.5° wide and we evaluate the mean level of CMB subtracted signal. Then, this is fitted with a cosecant model of the form T = Acscb + B. The offset is the value by which the intercept B is zero.

The results yielded by the two methods are in agreement. We set the zero levels of the maps released by the Planck collaboration to the estimates obtained using the second method. The numerical values are reported in Table 8.

4. Systematic effects that affect calibration

Raw gains from the nominal pipeline are sensitive to various effects related both to previous data processing steps and to instrument characteristics. A full treatment of systematic effects in the current release of LFI data is provided by Planck Collaboration III (2014); here we concentrate only on those systematics that have a significant impact on the calibration of the radiometers.

4.1. Impact of the optics on calibration estimation

The optical response of each radiometer, including the effect caused by the presence of the telescope and the baffles, impacts the estimation of the calibration constants. Apart from the effects due to the coupling of the CMB dipole with the full beam response described in Sect. 2.2, an important effect (particularly significant at 30 GHz) is the fact that the brightness of the Galactic plane produces a non-trivial spurious signal which biases the fit with the dipole.

thumbnail Fig. 11

Difference between the 30 GHz LFI map calibrated using the OSG calibration (Sect. 3.1) and the nominal 30 GHz map (calibrated using the 4 K method, see Sect. 3.2). The residual dipole visible in the map is due only to the latter calibration, as the nominal method removes any residual dipole. A few stripes are visible as well: they are caused by Galactic straylight affecting the fit with the dipole (OSG calibration), as hinted by the fact that such stripes are positive.

Consequently, for the current release, we have decided to calibrate the 30 GHz channels using the 4 K calibration, as described in Sect. 3.2. This procedure avoids the spurious signals induced by the sidelobes17 (see Fig. 11). In a future release, we plan to use the fully modelled sidelobe patterns to correct the timelines in the iterative calibration sequence, thereby using the same calibration scheme for all three frequency bands; we also treat polarization calibration.

The optical modelling of LFI, including extensive discussion of the sidelobes, is covered in Planck Collaboration IV (2014).

4.2. Efficiently convolving the dipole with a realistic beam

In Sect. 2.2 we mentioned that the procedure is based on a convolution of a reference dipole with the beam shape. This procedure can be time-consuming, as it must be done once for each sample measured by each radiometer. Fortunately, the spatial symmetry of the dipole signal allows us to derive a fast and elegant method to properly take the shape of the full beams into account when using the dipole to calibrate the data. We describe the mathematical details of the model in Appendix A; here we provide a physical interpretation.

The model applies a convolution with the full beam to Eq. (25), and it takes advantage of the high level of symmetry in the dipole to greatly simplify the calculation. The result of the convolution is still a dipole signal, but its direction and amplitude are slightly different from the dipole before the convolution, for the following reasons:

  • 1.

    the amplitude changes because of all the power entering thebeam from directions other than the beam axis;

  • 2.

    the direction changes because of asymmetries in the beam shape.

Such changes are characterized by a constant vector S, which only depends on the beam shape. The maximum difference between the amplitudes of the convolved dipole and of the dipole in the sky, under the simplifying hypothesis that vSun + vPlanckvSun, is: ΔTsc=TCMB|vSunc|(1|S|).\begin{equation} \label{eq:dipoleAmplitudeCorrection} \Delta T_{\mathrm{sc}}=\Tcmb\left|\frac{\vsun}{c}\right|\bigl(1-\left|\Svector\right|\bigr). \end{equation}(36)The direction of S in the beam reference frame represents the deviation of the effective axis of the dipole signal with respect to the axis of the dipole in the sky. A convenient measure of the overall deflection is represented by the deflection angle δz=arccos(ez·S/|S|),\begin{equation} \label{eq:DipoleAxisDeflection} \delta_{{z}} = \arccos(\vec{e}_z\cdot\Svector/|\Svector|), \end{equation}(37)where ez is the nominal direction of the beam.

Table 6

Dipole deflection and correction due to sidelobes.

thumbnail Fig. 12

Regression between dipole deflection (arcmin) and dipole amplitude correction ( μK) for each radiometer. Numbers are taken from Table 6. Side arms are in black, main arms are in white and have been shifted by 5 to improve readability.

Figure 12 plots the corresponding δz versus ΔTsc for each detector, and the numerical values are tabulated in Table 6. There is an evident linear correlation between the two quantities, with the best fit being δz=1.2368ΔTsc+0.2329.\begin{equation} \delta_{z} = 1.2368\,\Delta T_\mathrm{sc} + 0.2329. \end{equation}(38)The deflection angles are between \hbox{$1\parcm3$} and \hbox{$12\parcm6$}, so that the largest correction is 13  μK. It is interesting to note the slight level of asymmetry between the side and main arms of each feed-horn. This might lead to differences in corrections nearly as large as 1  μK. An example is given by the two arms of LFI28. In contrast, the two arms of LFI21 show no asymmetries.

As we already stated in Sect. 2.2, for this data release we have neglected ΔTsc (thus setting S∥ = 1), but we have considered the tilt effect given by δz. The tilt was considered not only when using Eq. (25) (i.e., fitting timestreams with the expected dipole signal), but also when we cleaned the calibrated data of the dipole itself (see point 7 in Sect. 3.1).

4.3. Imperfect behaviour of the ADC

As stated in Sect. 3, the calibration process also includes the conversion of the analogue detector voltages by the ADCs. This should be absorbed into the final radiometer calibration, but the ADCs can suffer a differential linearity problem, where the voltage step between binary levels varies slightly. The ADC employed use a digital to analogue circuit (DAC) and a successive approximation algorithm to match the voltages, so an imperfect step associated with a particular binary bit will lead to a recurring non-linear glitch when that bit changes. This can lead to a small but sharp deviation in the response curve as shown in Fig. 10 of Planck Collaboration III (2014). Since the slope of the response curve determines the effective calibration, a large gradient change can happen over a small range of voltage, potentially becoming the dominant source of gain uncertainty.

Such an effect is seen in the LFI radiometers for some channels, especially those with low back-end gain, where the quantization levels will be more evident. For this reason the radiometers of 44 GHz are the most affected, as shown in the upper panel of Fig. 13 for the worst affected LFI25S-11 channel (for more information, refer to Planck Collaboration III 2014).

The correction for this effect requires the reconstruction of the response curves, which can be inferred from the related difference in behaviour between white noise and detector voltages. The reason is that the white noise, like the dipole and sky temperature fluctuations, is sensitive to the gradient of the response curve, whereas the detector voltages are just determined by the point on the curve. This is explained in Appendix A of Planck Collaboration III (2014) and an example for LFI25S-11 is shown in that paper together with estimates of ADC residual errors in terms of systematic effects at the map level. The implementation in the pipeline uses splines18, fitted to pre-calculated template curves of the non-linearities. The result of correcting the TOD data is shown in the lower panel of Fig. 13, where the dipole gains and inverse sky voltage and white noise are much more consistent.

In the case where calibration used the level of the 4 K load, the uncorrected data would produce uncertainties directly in the calibration of the order of 5% leading to stripes of about 150  μK, due to the solar dipole being incorrectly removed. Using a dipole based calibration would correct the ADC non-linearity, but the need to low-pass filter it for an acceptable S/N would mean that gain variations shorter than the filter timescale were not corrected. This in turn would result in fine striping at the level of 2030  μK. Further, since the ADC non-linearity can differ between the two arms of a radiometer, there is also a direct impact on polarization through differential calibration errors. This is illustrated in Fig. 14, where we show the difference between maps made from the main and side arms of radiometer LFI25.

thumbnail Fig. 13

Time evolution of the calibration constant used to convert detector voltages into a thermodynamic temperature in Kelvin. The top panel shows the comparison for ADC uncorrected LFI25S-11 diode data between the raw dipole gains (grey dots) and the reciprocal of total-power sky detector voltage (black line), the latter scaled to have the same mean level as the gains. Two highly significant departures can be seen around day 160 and 560 together with lower level variations over most of the time range. The thick dark grey line shows inverse white noise estimates, again scaled to the same gain level, but filtered with a 100 ring moving median filter to reduce the scatter. As expected, this follows the dipole gains. The lower panel shows the same thing, but after the ADC correction has been applied to the TOD data.

thumbnail Fig. 14

Three degree smoothed map of the difference between the main and side arm of LFI25 before (top) and after (bottom) ADC non-linearity correction. Stripes can seen which are stronger in the region where the solar dipole peaks, as a result of residuals from calibration uncertainties. This relative uncertainty between radiometer arms directly affects polarization as shown here, since the main and side arm difference represents a pseudo-polarization.

It should be pointed out that the LFI and HFI ADC non-linearity problems are completely different, due to the different implementations of fast switching schemes. LFI use phase switching to swap sky and reference load signals, whereas HFI use a square wave modulation and AC coupling to avoid 1 /f contributions from the back-end electronics. More details about the ADCs used by HFI are found in Planck Collaboration VIII (2014).

5. Accuracy of the calibration

In this section we present results of consistency checks sensitive to calibration inaccuracies, as well as simulations which quantify the estimated level of calibration systematics in the data. Table 7 shows an overview of the elements that have been taken into account in estimating the calibration accuracy for LFI maps. Table 8 quantifies the impact of each element in the overall accuracy budget for the calibration.

5.1. Statistical uncertainty

5.1.1. Propagation of statistical errors from WMAP’s dipole estimate

As stated in Sect. 2.2, we have calibrated LFI data using the CMB dipole as measured by WMAP (Jarosik et al. 2011). In our calibration we used both the speed of the solar system in the CMB rest frame (vSun in Table 3) as well as the direction of motion (l, b). In this section we estimate how the quoted errors on these parameters propagate through the calculation of the calibration constant Kdip in Eq. (27).

thumbnail Fig. 15

Variation in the average level of the calibration constants of LFI27M, with (black line) or without (grey line) applying the Mademoiselle iterative code, as a function of the error in the solar system speed (top) and the displacement of the dipole axis (bottom). The two plots are normalized so that all the lines go through the point (0,0). The width of the vertical grey band corresponds to the error quoted by Jarosik et al. (2011) for vSun (top) and l (bottom).

Table 7

Elements considered in deriving the accuracy of the calibration.

Table 8

Accuracy in the calibration of LFI data.

We ran the LFI calibration pipeline a number of times for a subset19 of radiometers; for each run we changed either vSun or l from the nominal value listed in Table 3, and we compared the new average level Kdip\hbox{$\left<K_\mathrm{dip}'\right>$} of the calibration constant with respect to the level Kdip\hbox{$\left<K_\mathrm{dip}\right>$} of the nominal calibration. We also ran these tests without applying the iterative calibration code that cures the bias induced by the CMB and Galactic signal in dipole fitting (Mademoiselle; see point 5 in Sect. 3.1), in order to quantify the improvement in the stability of the calibration achieved by the iterative code.

Figure 15 shows the results of our simulations in the case of LFI27M (results for the other radiometers are in nearly perfect agreement with this). Mademoiselle’s ability to reduce the discrepancy KdipKdip\hbox{$\left<K_\mathrm{dip}'\right> - \left<K_\mathrm{dip}\right>$} is clear if one compares the error on Kdip with and without using Mademoiselle. Considering WMAP’s uncertainties on vSun and l and the results of our simulations, we can estimate that the relative error σKdip/Kdip due to the uncertainties in vSun, l, and b is σKdipKdip=0.19%(vSun)+0.05%(l)+0.01%(b)=0.25%,\begin{eqnarray} \frac{\sigma_{K_\mathrm{dip}}}{K_\mathrm{dip}} &=& 0.19\%~{\rm (v_\mathrm{Sun})} + 0.05\%~{\rm (l)} + 0.01\%~{\rm (b)} \nonumber\\ &=& 0.25\%, \end{eqnarray}(39)where the error for b has been estimated by simple proportionality using the error on l. (These numbers are the same for all the radiometers we analysed.)

5.1.2. Simulation of noise in dipole fitting

We have run a set of simulations to assess how much the statistical noise in the radiometric signal affects gain reconstruction using the CMB dipole signal. We first decalibrate the input map or dipole with a fiducial gain, the 4 K calibration, and then we simulate how the dipole calibration pipeline reconstructs those gains, i.e., we add the statistical noise, cut the low-dipole regions and then apply a smoothing filter.

We simulated separately the impact of the statistical noise acting on the modelled dipole and the Galaxy/CMB contribution; we model the input dipole using the WMAP direction and amplitude for the cosmological dipole (see Table 3) and NASA JPL Horizons Planck velocity for the orbital dipole. Moreover, we used Planck full frequency maps as the input Galactic and dipole-removed CMB signal.

We use a fiducial gain in order to make our simulation as realistic as possible, including the impact of the calibration pipeline on the underlying “true” gain. The 4 K calibration (see Sect. 3.2) offers a good choice, because it also includes realistic fluctuations on shorter timescales, which are expected to be smoothed out by the dipole calibration algorithm.

After decalibrating the input signal with the fiducial gain, we add a realization of the expected statistical gain error coming from the dipole fit due to white noise and to Galaxy masking. We model the statistical gain error according to the following equation: σG,iGi=2σ0Diτiηmask,i1+(f0fknee)α,\begin{equation} \label{eq:gainErrorModel} \frac{\sigma_{G,i}}{G_i} = \frac{\sqrt2 \sigma_0}{D_i \sqrt{\tau_i \eta_{\mathrm{mask},i}}} \sqrt{1 + \left(\frac{f_0}{f_\mathrm{knee}}\right)^\alpha}, \end{equation}(40)where i is an index identifying a pointing period, σG,i/Gi is the relative error on the gain Gi, σ0 is the noise-equivalent temperature of the radiometer, Di is the amplitude of the dipole signal during pointing period i (in Rayleigh-Jeans units), τi is the integration time of pointing period i, 0 ≤ ηmask,i ≤ 1 is a dimensionless coefficient that takes into account the loss of integration time due to Galaxy masking within pointing period i, f0 is the frequency of the dipole sinusoid seen by Planck’s scanning strategy (f0 = 16.7 mHz), and fknee and α are the constants that characterize the 1 /f noise for a given radiometer. The output of this step is equivalent to the “raw” dipole calibration as computed by the Mademoiselle iterative calibration software (see Sect. 3.1, point 5, and the Planck Collaboration II 2014).

The last step is to cut the low-dipole regions, replace them with a straight line, and then heavily smooth the data with a moving average filter of about 200 pointing periods. This is a simplified version of the wavelet-based filtering in the pipeline (Sect. 3.1, point 6). We run destriping on the output timelines and produce surveys and nominal mission maps of the noise for each frequency. Figure 16 shows the power spectrum of the artefacts produced by this simulation for the same timespan covered by this Planck data release.

thumbnail Fig. 16

Power spectrum of the simulated artefacts caused by errors in gain reconstruction (see Sect. 5.1), compared with Planck’s best-fit TT power spectrum model.

5.2. Impact of known systematics

5.2.1. ADC non-linearities

We have run a set of simulations on the non-linearity of the ADCs (see Sect. 4.3) in order to quantify its impact on the calibration of LFI. The simulations are described by Planck Collaboration III (2014), but we briefly recall the procedure here.

After we characterized the non-linearity of the ADCs to estimate the response curve R(Vi)\hbox{$R(V'_i)$} of the ADC for the 44 converters, we produced time-ordered data by summing Galactic, dipole, and CMB signals, as well as 1 /f noise. To do this we considered Planck’s scanning strategy and the measured characteristics of each LFI detector. We de-calibrated the TODs using the same gains used to calibrate flight data. We then produced two sets of maps:

  • 1.

    the first set uses these TODs and produces maps, which areimmune from the ADC effects;

  • 2.

    the second set filters the TODs using the inverse of the response function R in order to simulate the ADC non-linearity, and then uses the same procedure used for flight data to estimate a new response function, R (obviously, RR); finally the ADC correction code is applied to the data, and new maps are produced.

We considered the difference between the two sets of maps to be a reasonable estimate of the level of errors due to the uncertainties in the procedure for estimating ADC non-linearities. These differences reveal that such uncertainties introduce an error in the estimation of the calibration constant K (Eq. (1)) which is of the order of 0.1%.

5.2.2. Beam uncertainties

In Table 8 we quantify the error due to the fact that we considered monochromatic beams when estimating the vector S in Eq. (A.5). We have estimated the beam response of LFI’s radiometers (see Sect. 4.2) over their bandwidth using the GRASP software (see Planck Collaboration III 2014, for more information about this) and we have computed a new set of vectors S′(ν), which of course depend on the frequency ν. The errors we report under “Beam uncertainties” are equal to the average of the value SS(ν)\hbox{$\left\|\Svector\right\| - \bigl\|\left<\Svector'(\nu)\right>\bigr\|$} for the 22 radiometers, grouped according to their centre frequency.

5.3. Impact of unknown systematics

To estimate the impact of all those systematics which affect the calibration, but for which we do not have simulations or direct measurements at hand, we relied on internal consistency checks, namely inter-channel comparisons and null tests. We explain the logic behind each analysis as well as the results in the next paragraphs.

5.3.1. Inter-channel calibration consistency

A sensitive way to test the relative calibration among the different LFI radiometers is to make independent maps and compare their angular power spectra in the vicinity of the CMB acoustic peak. This has the advantage of testing the calibration on a source with the relevant amplitude and spectrum for our cosmology goals. To reduce the effects of noise bias on the power spectrum estimation, we intercompare the radiometers using cross-spectra; since the noise is quite uncorrelated among the radiometers, we obtain clean spectra this way. In order to compare any pair of radiometers, we first mask the Galaxy, point sources, and all unobserved pixels. We then calculate the cross-spectrum of maps made by each radiometer with maps of a third radiometer, and take the ratio. By comparing all possible combinations we average over any small impact from the choice of the third map. For example: ALFI18S,LFI19M=ClLFI18S×otherClLFI19M×other·\begin{equation} \label{eq:xspectraEquation} A_{\mathrm{LFI18S},\mathrm{LFI19M}} = \dfrac{C_l^{\mathrm{LFI18S} \times \mathrm{other}}}{C_l^{\mathrm{LFI19M} \times \mathrm{other}}}\cdot \end{equation}(41)In this case, “other” runs over LFI18M, LFI18S, and both radiometers of horns 20, 21, 22, and 23.

thumbnail Fig. 17

Intercomparison of the relative calibration of the LFI radiometers, as measured on the CMB acoustic peak by averaging the power spectrum from 100 < < 250. Note that we display both main arm (slightly to the left of each dotted, vertical line) and side arm (to the right) radiometers for each horn, as they are all calibrated independently. We also include the full frequency maps, labelled as f30, f44, and f70. LFI 70 GHz full frequency at 70% sky coverage is taken as reference.

We show the results of this in Fig. 17, which captures the relative gain deviation among all the radiometers, based on the first acoustic peak. The horizontal axis is the horn number, with points representing the main and side arm radiometers placed just left and just right of the corresponding horn number. Figure 17 also includes the gain deviations averaged over the full frequency, labelled as f30, f44 and f70. Interchannel consistency is everywhere within 1% of the mean at 44 and 70 GHz, while 30 GHz is severely affected by residual Galactic signal, as highlighted by the strong reduction between the 70% and 60% sky coverage masks20. This analysis includes corrections for the beams, the scanning strategy and mask deconvolution. In this figure, the deviations from the mean calibration appear to be correlated among radiometers. Most likely this is due to the fact that the main source of systematic errors in our calibration comes from our knowledge of the beam window functions. Since the radiometer labelling is related to the focal plane layout, there may well be a correlation between mis-estimated beam shape and radiometer number. Such systematic errors in beam estimation can come from small errors in the optical element positions or mirror figures. Improved beam models are a primary goal for future releases of the Planck data.

Figure 18 shows the results of a similar comparison between surveys, in this case comparing the full frequency estimates of the acoustic peak for surveys 1, 2, and 3. The full frequency comparison is even more striking, with each band remaining within ±0.15% over the three independent surveys. Of course, many systematics which plague calibration may be common to all channels, particularly within a frequency cohort; however, 1 /f noise, receiver degradation, and certain other sources of systematic uncertainties in the temperature calibration seem to be controlled to below 0.15%.

thumbnail Fig. 18

LFI cross-spectra between surveys. As in Fig. 17, ratios of the power spectra are computed in the range 50 < < 250.

5.3.2. Null tests

We have developed a number of tests to highlight possible issues related to instrumental systematic effects which are not properly corrected within the pipeline, or are related to known changes in the operating conditions of the instrument or to intrinsic instrument properties coupled with the sky, like stray-light from sidelobes. Such tests are also discussed by Planck Collaboration III (2014); here we concentrate on how those tests can be used to estimate the impact of calibration errors in LFI maps.

The idea behind the many tests we ran for this Planck data release is to compare pairs of distinct estimates of the sky signal, that should ideally be the same, such as:

  • comparing the sky signal measured during two surveys (notnecessarily consecutive), we call this kind of testsurvey-difference null tests;

  • comparing the sky signal measured by two radiometers, we call this a radiometer-difference null test;

  • comparing the map produced using only data taken in the first half of each pointing period with data taken in the other half. This is a half-ring null test.

Clearly, it is not trivial to determine the cause of each discrepancy in each comparison. The following criteria are useful in interpreting the results of these null tests:

  • 1.

    The results of radiometer-difference null tests can revealartefacts due to imbalances in the frequency response, as well as totheir different optical systematics. Such optical effects can becaused by an error in pointing reconstruction (which is thereforeunrelated to calibration), but also by two different ways of pickingup the astrophysical signal (including the dipole) through thesidelobes. The latter effect can be critical for calibration, as thesubtraction of an improper dipole signal leads to unwantedresiduals in the map.

  • 2.

    Survey-difference null tests are not affected by frequency response mismatches. However, they can be affected by the optical effects described above. Because of the scanning strategy employed by the Planck spacecraft, such systematics will be present only if an odd number survey is compared with an even survey, or vice versa, since odd surveys share the same scanning strategy, and the same applies for even surveys. (This is true for the first four surveys, including those considered here, but not for subsequent surveys, where the precession phase angle was changed.)

  • 3.

    Half-ring null tests are able to spot systematics at high frequency (more than 1 / 60 Hz, as this is the spinning frequency of the Planck spacecraft). Thus, calibration errors are unlikely to affect this kind of test, since we expect the gain of the radiometers to change on much longer time scales (days or weeks). In fact, we expect half-ring null test to be sensitive only to the level of unavoidable white noise in the data.

For all the reasons stated above, we believe that a fair upper limit of the calibration errors that are unrelated to optical effects can be deduced by studying odd-odd and even-even survey-difference null tests, as they are not affected by pointing errors, imbalance in frequency response, or “fast” systematics. Even-odd and odd-even differences are affected by systematics caused by optics as well. Therefore, these should be larger than the former and can also be used to produce upper limits for the calibration accuracy. Figure 19 shows two examples.

thumbnail Fig. 19

Survey difference maps at 30 GHz. Top: difference between survey 1 and 2. Middle: difference between survey 1 and 3. Note that the 12 difference map has sharper features, due to the different scanning strategy between odd and even surveys that prevents optical systematics from being cancelled in the subtraction. Bottom: the mask used to distinguish between CMB-dominated regions and Galactic regions when computing the numbers reported in Table 8 (30 GHz case).

We have used odd-odd survey difference maps to produce the numbers reported in the row “Unknown systematics” in Table 8. These numbers are the rms value of the pixels, after the maps have been degraded to a resolution which roughly coincides with the FWHM of the LFI beams. We subtracted from these values the part due to statistical noise, estimated from half-ring difference maps using the procedure described by Planck Collaboration III (2014). As noted above, these rms values represent upper limits for calibration inaccuracy, because some of the systematics affecting survey difference maps are unrelated to calibration. Values under the “Total” group have been calculated from odd-even survey difference maps; as noted above, they include optical systematics as well.

We show the power spectra of the even-odd and odd-odd null tests in Fig. 20, where we compare them with the estimated statistical errors of the gains (Sect. 5.1) and the spectra of half-ring maps. The latter provide an estimate of the level of statistical noise in the maps and generally agree with survey difference spectra for  > 20. This means that for a wide range of multipoles we do not expect any significant contribution of calibration systematics on the maps. For  < 20 there is some disagreement for the 30 GHz maps. This might indicate the presence of residual optical systematics in the data. In fact, the chief reason that induced us to use a different calibration for 30 GHz channels (using the 4 K total-power output, see Sect. 3.2) was to minimize the impact of optical systematics on the calibration of these channels (which suffer from a relatively high level of sidelobes).

thumbnail Fig. 20

Spectrum of the half-difference between Sky Survey (SS) 1 and 2, (SS1 − SS2) / 2 (odd-even number surveys, shown in frame A), and (SS1 − SS3) / 2 (odd-odd, frame B), compared with the half ring spectra for the same time period at the three LFI bands. We also show the simulated errors due to gain reconstruction (Sect. 5.1). Spectra have been binned into five samples each, in order to remove high-frequency noise and highlight the general trend. At high multipoles ( > 20) there is a good match between survey differences and half-rings, which means that discrepancies between survey differences are mainly due to statistical noise. Note that the biggest discrepancy between survey differences and halfrings happens for 30 GHz channels when comparing SS1 with SS2 (odd-even); this suggests that optical effects (sidelobes) are causing the discrepancy. Gain errors are calculated over the whole mission and are negligible except for the lowest multipoles of 44 GHz and 70 GHz spectra, where they probably account for the large-scale residuals found in survey difference maps.

5.4. Checks with external calibrations

5.4.1. Using bright point sources for relative calibration

thumbnail Fig. 21

Spectra (left) and per-survey and per-RCA measurements (right) for Orion A (top), Cas A (middle) and Tau A (bottom). For the spectra, the flux densities measured using aperture photometry are shown for LFI and WMAP, as well as the best-fitting power-law to the measurements (solid line) and a ±1% range (dotted line). The fit and data points from Weiland et al. (2011) are shown for Cas A and Orion A, and the Planck Catalogue of Compact Sources (PCCS) flux densities for all three sources are shown. For the per-RCA measurements, RCAs 1823 are at 70 GHz, 2426 at 44 GHz and 2728 at 30 GHz. For each RCA, the average from the three surveys is shown, followed by the measurements from each survey.

In order to perform an independent check of the relative calibration between different RCAs and also to test both the colour corrections and central frequencies of each LFI band, we look at three bright radio sources in the LFI maps: Orion A (M 42); Taurus A; and Cassiopeia A21. The emission in these three sources is due to synchrotron or free-free emission, such that they have very different spectra from the CMB. This means that colour corrections are important at the level of about 3–10% depending on the RCA, which is in excess of the uncertainties on the flux densities of these sources.

Comparisons between ERCSC flux densities (Planck Collaboration VII 2011) at 30, 44, and 70GHz and interpolated or extrapolated flux densities from the Karl G. Jansky Very Large Array (VLA) follow-up observations have previously shown good statistical consistency at the 3% level (Planck Collaboration XIV 2011; Kurinsky et al. 2013; Planck Collaboration XXVIII 2014). A comparison has also been made between the Planck-ATCA coeval observations (PACO) and PCCS catalogues in Planck Collaboration XXVIII (2014), which finds consistency at the level of around 4%. However, we ideally want to test the calibration much more accurately than this, which can be accomplished comparing different LFI measurements and by comparing these results to WMAP. Additionally, the sources that we examine here are significantly less variable than the typical source in the VLA and PACO tests.

We use the Planck single detector maps for each survey. We first average the main and side maps to create individual RCA maps per survey, which has the effect of cancelling out the polarization such that the maps are of total intensity only. We look at the individual survey maps, and the average of surveys 1–3. We also make use of the WMAP-9 deconvolved Stokes I sky maps (Bennett et al. 2013).

We measure source emission from the maps using aperture photometry, as described in Planck Collaboration XX (2011), with an aperture of 70 radius and a background annulus of 80100. By keeping the aperture and annuli sizes constant rather than changing them to reflect the resolution of the instrument, we ensure that we are measuring the same source extent and subtracting the same background emission at all frequencies, since the background may vary with distance due to the structure of the extended source, or background emission surrounding it. A correction factor for the source flux that falls outside of the aperture is applied as per Planck Collaboration XXVIII (2014); this factor is non-negligible for the WMAP data points. The measured emission, in TCMB, is converted to TRJ, and then into Jansky at the nominal frequency (28.4, 44.1 or 70.4 GHz as appropriate). The uncertainty in the flux densities is calculated using the rms of the pixels in the background annulus.

The properties of the sources are summarized in Table 9. The flux densities for the sources in the first section of the table are the APERFLUX flux densities from PCCS. We only use these here for consistency checks, however, as the PCCS flux densities are the average across all radiometers of a given frequency rather than the flux densities as measured by each radiometer. We note that there is a difference in reported flux densities from WMAP between Page et al. (2007) and Weiland et al. (2011) of up to around 8%, due to the method used: Page et al. (2007) used aperture photometry, and Weiland et al. (2011) fitted the beams to the sources. As such, care needs to be taken when comparing the numbers from the different analyses.

In order to calculate the necessary colour corrections, we iteratively calculate the amplitude (at a reference frequency of 33 GHz) and spectral index of the source based on the Planck and WMAP aperture photometry flux densities, the values for which are quoted in Table 9. We then use this spectral index to colour-correct the flux densities per RCA using quadratic fits to the colour correction values given in Sect. 2.3. The average flux densities, and the standard deviation calculated between the RCAs, both before and after colour correction, are given in Table 9. The percentage of the standard deviation to the mean is also given. When the colour corrections are applied, there are a few significant improvements in the standard deviations and no relevant degradation, giving confidence that the colour corrections are improving the consistency between the RCAs.

Table 9

Properties of three compact calibrators used to check the calibration: Orion A (M 42); Cas A; and Tau A (M 1).

Figure 21 shows the spectra of the three sources (left-hand column) and the flux densities from individual survey maps for the different RCAs (right-hand column). For Orion A, two sets of points differ significantly from the spectrum from aperture photometry. At WMAP 93.5 GHz, the measured flux density is much higher as it includes dust emission, which is not present at the LFI frequencies and as such is not considered here. Additionally, the PCCS aperflux is much steeper (α = −0.21) than the best fit to the aperture photometry here; this is most likely due to the different sized apertures used, which depend on frequency for PCCS, meaning that it will systematically exclude the more diffuse emission from the source than is included in this analysis. This is particularly relevant for Orion A due to its more complex morphology. For Cas A, we find very good agreement between the results. For Tau A, we find a slightly flatter spectrum (−0.287 ± 0.013) than the PCCS and Weiland et al. (2011) (−0.302 ± 0.005), and other analyses also report steeper spectra, e.g. Hafez et al. (2008) find −0.32 ± 0.01 at 30 GHz, and Macías-Pérez et al. (2010) find −0.296 ± 0.006; this is again likely due to the different aperture sizes considered here.

Although aperture size affects the comparison of the absolute flux densities, it does not affect the results between the different Planck RCAs at the same frequencies, or between the different survey maps for the same RCAs. There is general consistency for all RCAs between the surveys, within the uncertainties. Note that some of the sources were not observed in every survey due to the survey definitions, for example Cas A was not observed by RCAs 25 and 26 in survey 2. However, we do find some systematic differences in the results from different RCAs. At 28.4 GHz, RCA 27 is consistently lower than RCA 28 at the level of 2%; this difference does not change when colour corrections are applied as the corrections for those two RCAs are so similar. The differences at 44 GHz are 1.5%, with RCA 24 systematically slightly higher than the 25 and 26. This might be due to the beams, as RCA 24 has a smaller beam size than RCAs 25 and 26; however, this difference is expected to be smaller than the effect seen here. At 70 GHz, there are indications that RCA 18 is consistently high and RCA 19 is consistently low, with differences in the flux density between those two RCAs of up to 6% (for Orion A).

Table 10

Average ratio of flux densities for RCA pairs.

In order to better characterize these differences, we have studied how much the ratio SA/SB, the average ratio between compact source flux densities calculated using RCAs A and B, differs from unity. In addition to aperture photometry, we have estimated this ratio using two other methods:

  • 1.

    We used the template fitting code from Davieset al. (2006), run in a simpli-fied way (i.e., without making use of a covariance matrix fornoise or the CMB, such that it essentially does a least-squaresfit), to compare “template” maps of RCA 28(30 GHz), RCA 26 (44[en-tity!#x2009!]GHz) and RCA 18 (70[en-tity!#x2009!]GHz) with the other maps at the same frequencies.The maps have been smoothed to 1°, and a constant offset is used as asecond template to remove any differences in the offsets betweenthe template and the map. This provides an estimate of the ratioSA/SB for the all-sky coefficients between RCAs. We have run this analysis on the full, unmasked sky and the Galactic plane (|b| < 10°), which yields consistent results with those obtained through aperture photometry; in addition we have used the WMAP KQ75 mask on 3°-smoothed maps and find consistent results at 30 GHz, but better agreement at 44 and 70 GHz, where the maps are more dominated by the CMB.

  • 2.

    We combined pairs of RCA maps according to the formula mAγmB, with mA and mB the arrays of pixels for the two maps, and visually compared the three sources considered above. We found those values of γ that either made asymmetries in the residual beam patterns around point sources disappear (for 30 and 44 GHz), or that produced a source difference with the noise uncertainty (70 GHz). We then assumed that γSA/SB. Although this method is rather qualitative, the values we obtained differ from aperture photometry estimates by only about 1%.

Table 10 shows a comparison of the average fractional difference between source densities calculated using two RCAs, e.g., RCA 18 vs. RCA 19. The table reports an estimate of the percentage discrepancy between the channels (calculated simply by averaging the discrepancies found by aperture photometry, template fitting and visual inspection of sources), as well as the discrepancy minus the expected difference in colour corrections between the RCAs. We initially assume α = −1 and tabulate the difference in colour corrections as \hbox{$\delta\cc$} in Table 10. The “corrected discrepancy” in column 5 is the sum of \hbox{$\delta\cc$} and the raw discrepancy. We also give \hbox{$\delta\cc$} for α = 0 for comparison; these two values of α span the range of spectral indices of the sources considered. The expected uncertainties on the colour corrections for an RCA for α = −1 are 0.42%, 1.38% and 1.53% for 30, 44, and 70 GHz, respectively, such that the effects shown in Table 10 are 4σ at 30 and 70 GHz.

As the consistency between the RCAs is seen to be significantly better when comparing CMB emission between the RCAs (e.g., Sect. 5.3.1), we conclude that the effects seen here are likely due to differences in bandpasses or the intermediate beams between the RCAs, although neither of these is expected to be sufficiently large to explain the differences seen here. These effects will be investigated further prior to the next release of Planck data.

5.4.2. Planet flux densities

Table 11

Visibility times of planets.

Planets can be used as a source for calibration cross-checks. In particular, Jupiter has several advantages: its signal is up to fifty times higher than the receiver noise per scan; it is visible to Planck about twice a year; it has a relatively well known spectrum; and at LFI’s resolution it is point-like. Table 11 lists the dates when planets crossed LFI beams, and Fig. 22 gives a visual timeline of these events.

The model for the time dependent signal produced by a planet in a timeline (Cremonese et al. 2002; Maris et al. 2007) is: Ip(ti)=N-14π[B(xb)Ip,0(xbU(ti)xp(ti))+Ibg(ti)],\begin{equation} \label{eq:planets:row} \PlanetI(t_i) = N^{-1} \int_{4\pi}\ud\Omega \left[\BeamRd(\Pointing) \PlanetIz\bigl(\Pointing-\RotBeamObs(t_i)\PlanetPointing(t_i)\bigr) + \BackgroundI(t_i)\right], \end{equation}(42)where Ip,0 is the brightness distribution across the projected planet disk, xp(ti) represents the direction in which a planet is seen from the instrument at the sampling time ti, U(ti) is the matrix that converts pointing from the Ecliptic reference frame to the beam reference frame, and Ibg(ti) is the observed background. We assume that the radiometers have an elliptical Gaussian beam pattern, and we neglect complications such as differential temperature distributions across the planetary disk, phase effects, and limb darkening. Therefore, Eq. (42) reduces to: Ipp,0(ΔΔ0b0b)2(1fcosθobs)exp(12yp𝒞-1yp)+Ibg,\begin{equation} \PlanetI \approx \PlanetIzAver \left(\frac{\Delta}{\Delta_0} \frac{b_0}{b}\right)^{2} \left(1-f\cos\theta_{\mathrm{obs}} \right) \exp\left( -\frac{1}{2} \PlanetPointingBeam^{\dagger} \mathcal{C}^{-1} \PlanetPointingBeam \right) + \BackgroundI, \end{equation}(43)where yp = Uxp, b is the beam FWHM, f is the planetary disk flattening, θobs is the observer planeto-centric latitude, and Δ is the distance between the planet and the observer. The diagonal matrix \hbox{$\mathcal{C}=b^2/8\log2\,\mathrm{diag}(\epsilon, 1/\epsilon)$} represents the beam shape, whose ellipticity is ϵ. The time dependency of Ip, \hbox{$\PlanetIzAver$}, Δ, θobs, U, and xp are omitted. The equation assumes a beam-averaged planet brightness \hbox{$\PlanetIzAver$} calculated for a fiducial planet-observer distance Δ0 and beam FWHM b0, in order to account for beam-to-beam variability.

The model is used to fit \hbox{$\PlanetIzAver$} onto the timelines of each feed-horn, taken separately, by using a least-squares procedure. Samples for each timeline are accepted as valid data of the fit if their instantaneous angular distance from the planet is smaller than 5° at the epoch of observation. The background is assumed to be constant over the acceptance disc and is left as a free parameter. In order to properly destripe the data, we have used the baselines calculated by Madam (Keihänen et al. 2010), the standard map-making tool used to produce the LFI maps.

thumbnail Fig. 22

Timeline of planet crossings. Each line shows the times when the planet fell within the beam of at least one of the radiometers at 30, 44, or 70 GHz. Grey bands at the edges mark the start of the survey and the end of the period considered in the 2013 data release. Vertical grey lines mark the separation between sky surveys.

The histogram of the data in the timelines can be approximated as the sum of two Gaussian distributions, one due to the signal and one due to the background. The histogram of differences of timelines and the fitted model overlap very well, one of the peaks assessing proper separation of the planetary signal. The width of the residual peak is an estimate of the confusion noise, dominated by white noise and CMB fluctuations. Table 12 reports the measurements of the brightness temperature for a number of planets. The two quoted uncertainties are the maximum intra-survey difference with respect to the median of the measures and the confusion noise measured on the fitted data. The central wavelengths assumed for each of the three bands are 10.56 mm, 6.80 mm, and 4.26 mm (taken from the LFI instrument model, see Planck Collaboration 2013).

Jupiter is the only planet bright enough to be detected in the timeline without averaging. This is the reason why the random uncertainty is much smaller than the maximal survey-by-survey variation. Such variation can be ascribed to a number of small systematics not completely understood yet. One of them is the fact that planets have been extracted as soon as they were observed, so that different observations have had slightly different calibration procedures. Despite having a slightly worse S/N, the same is true for Saturn. However, we have not introduced any correction for the effect of Saturn’s rings yet. In the same manner the observations of Mars are not corrected for diurnal variability due to the rotation of the planet. Uranus and Neptune have quite low S/N, in particular at 30 GHz, and therefore they are very sensitive to the confusion noise, background, uncertainties in beam orientations, and aperture corrections.

Figure 23 compares the Jupiter spectrum from LFI averaged through the surveys with the WMAP measurements (Weiland et al. 2011). It is possible to see the good agreement between the two datasets.

thumbnail Fig. 23

Jupiter spectrum for LFI compared to the WMAP spectrum (Weiland et al. 2011). Planck data are taken from Table 12. (The LFI points have been rescaled by a factor, 1.0693, which takes Jupiter’s oblateness into account, in order to make them easier to compare with WMAP’s.) The upper frame shows the brightness temperatures as a function of the central wavelength, alongside a simple linear model TJ(λ) = 187.8 K − 4.5 K cm-1λ, which by construction passes through the WMAP’s points at λ = 3.2 mm and λ = 9.1 mm. For both Planck and WMAP, measurement errors are smaller than the size of the symbols. In the bottom frame, we rescaled our points to the linear model in order to better show deviations from it. The error bars for LFI data show the uncertainties quoted in Table 12, as well as the overall calibration errors listed in Table 8.

Table 12

Averaged brightness temperatures for planetsa. We have applied no correction for planetary disk oblateness.

5.5. Consistency with HFI and WMAP

A key aspect of Planck’s data analysis is the internal consistency of calibrated maps and power spectra obtained by LFI and HFI detectors. Because the two instruments employ highly independent technologies, inter-instrument comparisons provide useful indications on systematic effects of instrumental origin. An even more independent calibration cross-check can be made by comparing maps and power spectra obtained by LFI and WMAP in similar frequency bands. Because of the importance and complexity of these comparisons, a full paper of this 2013 release is dedicated to these issues, Planck Collaboration XXXI (2014).

The LFI 70 GHz and HFI 100 GHz power spectra in the region of the first CMB acoustic peak (multipole range 70390) are consistent within 0.8%, corresponding to a map calibration consistency of ~0.4%. These values, which include a small correction for unresolved sources, are within the LFI and HFI calibration uncertainties discussed in this paper and in Planck Collaboration VIII (2014). In Planck Collaboration XXXI (2014) we also show that an improved model of HFI near sidelobes, which were not fully accounted for initially, leads to a further improvement in the LFI-HFI consistency by a factor of 2. Such good agreement between LFI and HFI, while not a guarantee, is an indication of lack of major undetected systematics and of good calibration consistency.

A larger deviation, of order 1.8% in the power spectrum (~0.9% in calibrated maps), is found between LFI 70 GHz and WMAP V-band in the region of the first peak (the former measuring less power than the latter), a 1.4σ tension suggesting some undetected effect in LFI, in WMAP, or in both. These could be due to a combination of errors in the calibration process or beam window function, issues in the data processing, or imprecise estimation of the solar dipole. Our estimates of the solar dipole based on LFI 44 GHz orbital dipole calibration (Table 5) suggest good consistency with WMAP. Our results, however, are very preliminary, and more redundancy and cross-checks are needed before an assessment of inter-calibration at sub-percent level can be performed. We note that a ~1% calibration discrepancy would result in a noticeable offset in the Jupiter temperature as measured by LFI and by WMAP (Fig. 23, bottom panel). Taken at face value, the combination of the good agreement of these two sets of measurements and the 1.8% discrepancy of the power spectra at degree scales (first peak of the CMB) might suggest a beam or window function issue, either in LFI or WMAP. However, these deviations are (marginally) within uncertainties. The 2014 Planck release will greatly increase the LFI data redundancy compared to the present 2013 release (from 2.5 to 8 surveys, and from 2 to 7 Jupiter measurements), which we expect will help to settle the issue.

6. Conclusions and next steps

In this paper we have described the procedures used to calibrate Planck/LFI data and the ways we used to assess the accuracy of our calibration. We have shown that the level of consistency in the maps is quite good, since discrepancies are roughly 0.6% at 44 and 70 GHz, and 0.8% at 30 GHz.

However, we believe there are areas where we can significantly improve our understanding of the instrument and therefore produce a better calibration, e.g., modelling of far sidelobes (see Sects. 4.1 and 4.2) and proper modelling of variations in the noise temperature of the radiometers (Sect. 3.2). We therefore need to concentrate our efforts in improving our algorithms and analysis methods for the next Planck data delivery, in order also to provide a sound polarization calibration.

An important point which is still missing is the production of a full characterization of the dipole that is independent of WMAP. This would in turn allow us to calibrate the Planck/LFI radiometers absolutely. As explained in Sect. 3.3, we were able to obtain some encouraging results, but not good enough to avoid using WMAP’s characterization of the dipole in our calibration pipeline. We aim to do so for the next release.

Another important point is to fully characterize the impact of optical systematics on the calibration. Our efficient dipole convolver (Sect. 4.2) is a testimony to the work we have put in this task, but much more work is needed to fully understand the impact of far sidelobes on the calibration. We plan to run simulations to assess how much our uncertainty in the knowledge of the optical parameters of the beams impacts the estimation of gains and the production of calibrated timelines, and to further improve our model of the beams themselves.

Finally, we are determined to understand the origin of all the “unknown systematics” listed in the corresponding row in Table 8, by means of simulations and more refined models of the radiometer.


1

Planck (http://www.esa.int/Planck) is a project of the European Space Agency (ESA) with instruments provided by two scientific consortia funded by ESA member states (in particular the lead countries France and Italy), with contributions from NASA (USA) and telescope reflectors provided by a collaboration between ESA and a scientific consortium led and funded by Denmark.

2

In this work we use the following notation for convolution:

( A B ) ( θ,φ ) = 4 π A ( θ , φ ) B ( θ θ φ ) d Ω . $$ (A * B)(\theta, \phi) = \int_{4\pi} A(\theta', \phi') B(\theta - \theta', \phi - \phi')\,\ud\Omega'. $$

3

Although LFI directly measures Vout, it can be considered a differential instrument (Bersanelli et al. 2010) as the analysis is performed on the value VoutrVref, where Vref is the measurement of the temperature of a stable 4 K heat load (Sect. 3.2) and r is a coefficient which removes the contribution of M from both Vout and Vref, so that the time average of VoutrVref is zero. Refer to Planck Collaboration II (2014) for further details.

4

If the quantity f(t) is affected by statistical noise at high frequencies, as it is the case for all the quantities considered here, it is necessary to apply some kind of low pass filter to it before applying Eq. (2) in order to obtain meaningful results.

5

The number of sky surveys in this Planck data release is two and a half.

6

The scanning strategy has been designed such that this amplitude never vanishes, see Dupac & Tauber (2005). However, as the scan axis changes, variations in the observed amplitude do occur and they affect the accuracy of the calibration, as we discuss in Sect. 3.1.

7

This step is based on an algorithm which starts from the approximation Tsky + DD and then refines the solution iteratively. The real algorithm is more complex than this, as it removes Tsky at the same time as the least-square fit discussed later in this section: the details of the algorithm are presented in Sect. 3.1.

8

Although the equation is mathematically correct, we note that it is of little use for a numerical implementation, as the denominator is a sinusoid which periodically goes to zero, thus making the quantity diverge to infinity.

9

In the context of this paper, a pencil beam Bpencil is a Dirac delta function centered on the beam axis êb:

B pencil ( ) = δ ( b ) . $$ B_\text{pencil} (\hat{x}) = \delta\bigr(\hat{x} - \hat{e}_{\rm b}\bigr). $$

10

The quantity 1 − fside is approximately equal to S. However, as explained in Appendix A, the vector S models the coupling of the full beam (including the main beam, which causes a tiny smearing effect because of its finite FWHM) with the dipole and only uses the first directional moments of the beam shape.

11

Unlike ˜Tsky\hbox{$\tilde{T}_\mathrm{sky}$}, Tsky is the sky temperature as seen through a pencil beam, and therefore it contains information at every angular scale. But obviously, in the context of the overall calibration level of LFI, we are interested only in the overall level of the sky temperature, say for angles \hbox{$0\pdeg5$}. We thus ignore any scientific information contained in Tsky at smaller scale.

12

Note however that, even if the calibration constants Ki are not affected by uncertainties in beam shapes, this is not necessarily true for the calibrated data. After having applied the calibration factors, we must remove the dipole signal convolved with the beam from the data, and therefore any uncertainty in the beam shape will lead to a systematic error in the calibrated data, even if the 4 K calibration is used.

13

Most of the pixels in the maps contain no data, since during one pointing period the beam paints a thin circle in the sky. We assume hereafter that the index k runs only through the pixels which have been hit at least once.

14

The error from the first-order approximation in Eq. (31) is of the order of 0.05%.

15

In principle any value for Vref,0 might be used. However, the fact that we derived Eq. (32) using a Taylor expansion of K(t) around Vref,0 suggest that we use a value of the voltage that is the closest to all the values of V(t) we expect during the survey, in order to improve the accuracy of the first-order approximation. Depending on what we mean by “closest”, we might either choose the median or the mean of V(t); in this context we found that the difference between these quantities is probably negligible, as it is always less than 0.5%.

16

We chose this region since it is nearly free of bright point sources and is well representative of the Galactic diffuse emission.

17

Note however that the two methods produce maps that show a remarkable agreement: their peak-to-peak difference, if we neglect a few outlying pixels, is of the order of a few tens of  μK, thus of the same order of magnitude as the rms of the survey difference maps discussed in Sect. 5.3.2.

18

We use the spline functions provided by the GNU Scientific Library (Galassi et al. 2003).

19

Specifically, we considered LFI18M, LFI18S (70 GHz), LFI24M, LFI24S (44 GHz), LFI27M, and LFI28M (30 GHz).

20

These masks are the same used for component separation (Planck Collaboration XII 2014).

21

Orion A and Tau A are not expected to vary significantly over the time scales relevant here. Cas A has a secular decrease of ~0.6% at high frequencies (O’Sullivan & Green 1999), which over the five year time difference between the averaged WMAP and Planck datasets will add to 3%. This has not been taken into account in this analysis; however, it has a negligible effect on the measured spectral index of the source that is well within the uncertainties.

22

Higher-order terms result in corrections at least a thousand times smaller and are therefore neglected.

Acknowledgments

The development of Planck has been supported by: ESA; CNES and CNRS/INSU-IN2P3-INP (France); ASI, CNR, and INAF (Italy); NASA and DoE (USA); STFC and UKSA (UK); CSIC, MICINN, JA and RES (Spain); Tekes, AoF and CSC (Finland); DLR and MPG (Germany); CSA (Canada); DTU Space (Denmark); SER/SSO (Switzerland); RCN (Norway); SFI (Ireland); FCT/MCTES (Portugal); and PRACE (EU). A description of the Planck Collaboration and a list of its members, including the technical or scientific activities in which they have been involved, can be found at http://www.sciops.esa.int/index.php?project=planck&page=Planck_Collaboration.

References

  1. Bennett, C. L., Hill, R. S., Hinshaw, G., et al. 2003, ApJS, 148, 97 [NASA ADS] [CrossRef] [Google Scholar]
  2. Bennett, C. L., Larson, D., Weiland, J. L., et al. 2013, ApJS, 208, 20 [Google Scholar]
  3. Bersanelli, M., Muciaccia, P. F., Natoli, P., Vittorio, N., & Mandolesi, N. 1997, A&AS, 121, 393 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  4. Bersanelli, M., Mandolesi, N., Butler, R. C., et al. 2010, A&A, 520, A4 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  5. Cappellini, B., Maino, D., Albetti, G., et al. 2003, A&A, 409, 375 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  6. Cremonese, G., Marzari, F., Burigana, C., & Maris, M. 2002, New A, 7, 483 [NASA ADS] [CrossRef] [Google Scholar]
  7. Davies, R. D., Dickinson, C., Banday, A. J., et al. 2006, MNRAS, 370, 1125 [NASA ADS] [CrossRef] [Google Scholar]
  8. Dupac, X., & Tauber, J. 2005, A&A, 430, 363 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  9. Galassi, M., Davies, J., Theiler, J., et al. 2003, Gnu Scientific Library: Reference Manual (Network Theory Ltd.) [Google Scholar]
  10. Górski, K. M., Hivon, E., Banday, A. J., et al. 2005, ApJ, 622, 759 [NASA ADS] [CrossRef] [Google Scholar]
  11. Hafez, Y. A., Davies, R. D., Davis, R. J., et al. 2008, MNRAS, 388, 1775 [Google Scholar]
  12. Hinshaw, G., Weiland, J. L., Hill, R. S., et al. 2009, ApJS, 180, 225 [NASA ADS] [CrossRef] [Google Scholar]
  13. Jarosik, N., Barnes, C., Greason, M. R., et al. 2007, ApJS, 170, 263 [NASA ADS] [CrossRef] [Google Scholar]
  14. Jarosik, N., Bennett, C. L., Dunkley, J., et al. 2011, ApJS, 192, 14 [NASA ADS] [CrossRef] [Google Scholar]
  15. Keihänen, E., Keskitalo, R., Kurki-Suonio, H., Poutanen, T., & Sirviö, A. 2010, A&A, 510, A57 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  16. Kogut, A., Banday, A. J., Bennett, C. L., et al. 1996, ApJ, 470, 653 [NASA ADS] [CrossRef] [Google Scholar]
  17. Kurinsky, N., Sajina, A., Partridge, B., et al. 2013, A&A, 549, A133 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  18. Lamarre, J., Puget, J., Ade, P. A. R., et al. 2010, A&A, 520, A9 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  19. Leahy, J. P., Bersanelli, M., D’Arcangelo, O., et al. 2010, A&A, 520, A8 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  20. Macías-Pérez, J. F., Mayet, F., Aumont, J., & Désert, F.-X. 2010, ApJ, 711, 417 [NASA ADS] [CrossRef] [Google Scholar]
  21. Maris, M., Carraro, G., & Parisi, M. G. 2007, A&A, 472, 311 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  22. Mather, J. C., Fixsen, D. J., Shafer, R. A., Mosier, C., & Wilkinson, D. T. 1999, ApJ, 512, 511 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  23. Mennella, A., Bersanelli, M., Butler, R. C., et al. 2010, A&A, 520, A5 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  24. Mennella, A., Butler, R. C., Curto, A., et al. 2011, A&A, 536, A3 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  25. O’Sullivan, C., & Green, D. A. 1999, MNRAS, 303, 575 [Google Scholar]
  26. Page, L., Hinshaw, G., Komatsu, E., et al. 2007, ApJS, 170, 335 [NASA ADS] [CrossRef] [Google Scholar]
  27. Peebles, P. J. E., & Wilkinson, D. T. 1968, Phys. Rev., 174, 2168 [NASA ADS] [CrossRef] [Google Scholar]
  28. Planck Collaboration I. 2011, A&A, 536, A1 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  29. Planck Collaboration II. 2011, A&A, 536, A2 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  30. Planck Collaboration VII. 2011, A&A, 536, A7 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  31. Planck Collaboration XIV. 2011, A&A, 536, A14 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  32. Planck Collaboration XX. 2011, A&A, 536, A20 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  33. Planck Collaboration 2013, The Explanatory Supplement to the Planck 2013 results http://www.sciops.esa.int/wikiSI/planckpla/index.php?title=Main_Page (ESA) [Google Scholar]
  34. Planck Collaboration I. 2014, A&A, 571, A1 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  35. Planck Collaboration II. 2014, A&A, 571, A2 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  36. Planck Collaboration III. 2014, A&A, 571, A3 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  37. Planck Collaboration IV. 2014, A&A, 571, A4 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  38. Planck Collaboration V. 2014, A&A, 571, A5 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  39. Planck Collaboration VI. 2014, A&A, 571, A6 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  40. Planck Collaboration VII. 2014, A&A, 571, A7 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  41. Planck Collaboration VIII. 2014, A&A, 571, A8 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  42. Planck Collaboration IX. 2014, A&A, 571, A9 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  43. Planck Collaboration X. 2014, A&A, 571, A10 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  44. Planck Collaboration XI. 2014, A&A, 571, A11 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  45. Planck Collaboration XII. 2014, A&A, 571, A12 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  46. Planck Collaboration XIII. 2014, A&A, 571, A13 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  47. Planck Collaboration XIV. 2014, A&A, 571, A14 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  48. Planck Collaboration XV. 2014, A&A, 571, A15 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  49. Planck Collaboration XVI. 2014, A&A, 571, A16 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  50. Planck Collaboration XVII. 2014, A&A, 571, A17 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  51. Planck Collaboration XVIII. 2014, A&A, 571, A18 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  52. Planck Collaboration XIX. 2014, A&A, 571, A19 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  53. Planck Collaboration XX. 2014, A&A, 571, A20 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  54. Planck Collaboration XXI. 2014, A&A, 571, A21 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  55. Planck Collaboration XXII. 2014, A&A, 571, A22 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  56. Planck Collaboration XXIII. 2014, A&A, 571, A23 [NASA ADS] [CrossRef] [EDP Sciences] [MathSciNet] [PubMed] [Google Scholar]
  57. Planck Collaboration XXIV. 2014, A&A, 571, A24 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  58. Planck Collaboration XXV. 2014, A&A, 571, A25 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  59. Planck Collaboration XXVI. 2014, A&A, 571, A26 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  60. Planck Collaboration XXVII. 2014, A&A, 571, A27 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  61. Planck Collaboration XXVIII. 2014, A&A, 571, A28 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  62. Planck Collaboration XXIX. 2014, A&A, 571, A29 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  63. Planck Collaboration XXX. 2014, A&A, 571, A30 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  64. Planck Collaboration XXXI. 2014, A&A, 571, A31 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  65. Tauber, J. A., Mandolesi, N., Puget, J., et al. 2010, A&A, 520, A1 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  66. Terenzi, L., Salmon, M. J., Colin, A., et al. 2009, J. Instr., 4, 2012 [NASA ADS] [Google Scholar]
  67. Valenziano, L., Cuttaia, F., De Rosa, A., et al. 2009, J. Instr., 4, 2006 [Google Scholar]
  68. Villa, F., Terenzi, L., Sandri, M., et al. 2010, A&A, 520, A6 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  69. Weiland, J. L., Odegard, N., Hill, R. S., et al. 2011, ApJS, 192, 19 [Google Scholar]
  70. Zacchei, A., Maino, D., Baccigalupi, C., et al. 2011, A&A, 536, A5 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  71. Zonca, A., Franceschet, C., Battaglia, P., et al. 2009, J. Instr., 4, 2010 [NASA ADS] [CrossRef] [Google Scholar]

Appendix A: Fast convolution of the beam with the dipole

In this section we provide the details of the model used to convolve the dipole signal used in the calibration with the beam response over the full sky (Sect. 4.2).

Appendix A.1: Analytical model

Our starting point is Eq. (25), which relates the dipole signal (as measured by a pencil beam) with the combined velocity of the spacecraft and of the solar system with respect to the CMB rest frame. Following Peebles & Wilkinson (1968), we rewrite Eq. (25) as ΔTδ(ti)TCMB=x(ti)·DE+(x·DE)212|DE|2+𝒪(|DE|3),\appendix \setcounter{section}{1} \begin{equation} \label{eq:dipole:extended} \frac{\DeltaTDipoleDirac(t_i)}{\Tcmb} = \PointingE(t_i) \cdot \DipoleE + \left(\PointingE\cdot\DipoleE\right)^2 - \frac{1}{2}|\DipoleE|^2 + \mathcal{O}\left(|\DipoleE|^3\right), \end{equation}(A.1)where ΔTδ is the cosmological kinematic signal as measured by a pencil beam, x is the pointing direction in the Ecliptic reference frame and DE = (vSun + vPlanck) /c in the same reference frame. The equation accounts22 for both the CMB dipole and the relativistic transverse Doppler effect, since the latter can be considered as a correction to the quadrupole proportional to TCMB | vSun/c | 2 ≈ 3.8  μK. (We can safely discard 12|DE|2\hbox{$- \frac{1}{2}|\DipoleE|^2$}, since it is a constant and plays no role in the calibration.) We denote with xb = (xb,yb,zb) the observing direction in the reference frame of the beam. Then the convolved dipole signal is ΔT(t)TCMB=N4πB(xb)xb·U(t)DE+N4πB(xb)(xb·U(t)DE)2,\appendix \setcounter{section}{1} \begin{eqnarray} \frac{\DeltaTDipole(t)}{\Tcmb} &= &N \int_{4\pi} \ud\Omega\,\BeamRd(\Pointing)\,\Pointing \cdot \RotBeamObs(t)\DipoleE \nonumber\\ &&\ + N \int_{4\pi} \ud\Omega\,\BeamRd(\Pointing) \bigl(\Pointing \cdot \RotBeamObs(t)\DipoleE\bigr)^2, \end{eqnarray}(A.2)where U(t) is the matrix which transforms vectors from the Ecliptic reference frame to the beam reference frame, and N is a normalization constant: N-1=4πB(xb).\appendix \setcounter{section}{1} \begin{equation} \label{eq:beamConvolveNormalizationConstant} N^{-1} = \int_{4\pi} \ud\Omega\,B(\Pointing). \end{equation}(A.3)The directional moments of the beam are defined as Ml,m,n=N4πB(xb)xblybmzbn.\appendix \setcounter{section}{1} \begin{equation} \label{eq:directional:moments} \RadiometerM{l,m,n} = N \int_{4\pi} \ud\Omega\,\BeamRd(\Pointing)\,\PointingBx^l\,\PointingBy^m\,\PointingBz^n. \end{equation}(A.4)They depend only on the shape of the beam and their value does not change during the mission. If we set S=(M1,0,0,M0,1,0,M0,0,1)\appendix \setcounter{section}{1} \begin{equation} \label{eq:radiometerS} \Svector= \bigl(\RadiometerM{1,0,0},\RadiometerM{0,1,0},\RadiometerM{0,0,1}\bigr) \end{equation}(A.5)(a vector in the beam reference frame) and A=(M2,0,0,M1,1,0,M1,0,1M1,1,0,M0,2,0,M0,1,1M1,0,1,M0,1,1,M0,0,2)\appendix \setcounter{section}{1} \begin{equation} \label{eq:radiometerA} \RadiometerA=\left( \begin{array}{ccc} \RadiometerM{2,0,0}, & \RadiometerM{1,1,0}, & \RadiometerM{1,0,1} \\ \RadiometerM{1,1,0}, & \RadiometerM{0,2,0}, & \RadiometerM{0,1,1} \\ \RadiometerM{1,0,1}, & \RadiometerM{0,1,1}, & \RadiometerM{0,0,2} \\ \end{array} \right) \end{equation}(A.6)(a symmetric matrix), then Eq. (A.1) reduces to the bilinear form ΔT(t)TCMB=DEU(t)S+DEU(t)AU(t)DE.\appendix \setcounter{section}{1} \begin{equation} \frac{\Delta T(t)}{\Tcmb} = \vec{D}_E ^{\dagger}\RotBeamObs(t)^{\dagger} \Svector + \vec{D}_E^{\dagger} \RotBeamObs(t)^{\dagger} \RadiometerA\RotBeamObs(t) \DipoleE. \end{equation}(A.7)Because of a bug in the code which implemented Eq. (A.1), the value of (x·DE)2\hbox{$\left(\PointingE\cdot\DipoleE\right)^2$} was wrongly divided by two before the subtraction. Therefore, the LFI maps in the Planck 2013 data release still have half of the kinematic quadrupole. This residual quadrupole has an amplitude of TCMB | vSun/c | 2/ 2 ≈ 1.9  μK, and it will be properly removed in the next Planck data release.

Appendix A.2: Numerical calculation of the directional moments

The computation of the components of S (Eq. (A.5)) and A (Eq. (A.6)) was based on the integration of separate GRASP maps for both sidelobes and main beam, plus intermediated beams computed for each radiometer at its nominal central frequency, i.e., 30 GHz, 44 GHz, and 70 GHz. In this context, sidelobes are defined as the part of the beam pattern outside from the beam optical axis. The inner part of the beam pattern defines the intermediate beam and main beam maps.

Each map takes the small differences in the optical path for each radiometer into account, given its polarization and location in the focal-plane. For sidelobes, we used GRASP maps with a resolution of 0.5° along the azimuthal angle and 0.5° along the zenith angle. For intermediate and main beams, the resolution is 0.5° (azimuth) and 1 (zenith). We integrated Eq. (A.4) separately for the intermediate beam and the sidelobes, and then we summed them together. (The same was done for the normalization constant N, Eq. (A.3).) To compute the integral, we converted GRASP maps into HEALPix maps (Górski et al. 2005) by bilinear interpolation and applied a simple midpoint algorithm. We chose the resolution of the HEALPix maps in order to have a resolution much smaller than that of the corresponding GRASP maps. Sidelobes were gridded onto an HEALPix map with Nside = 1024, and intermediate beams onto a map with resolution equivalent to Nside = 65 536.

In order to check the convergence, we computed the value of Ml,m,n a number of times for increasing values of Nside. All the integrals showed a regular convergence curve. The largest Nside was fixed by having Ml,m,n(Nside) / Ml,m,n(Nside/ 2) − 1 < 10-3 for the moment with the slower convergence (including N).

The beam pattern changes over the bandpass of each radiometer, causing the moments Ml,m,n to change slightly with frequency. However, the change mainly affects the sidelobes, which contribute to less than 0.5% of the full-sky average. For temperature maps it is therefore enough to use a monochromatic correction.

All Tables

Table 1

Multiplicative colour corrections \hbox{$\cc(\alpha)$} for individual LFI radiometer chain assemblies and for the band average maps.

Table 2

Methods used to calibrate the radiometers.

Table 3

Parameters used in the model of the dipole signal.

Table 4

Dipole residuals and correction factors applied to the 4 K calibration at 30 GHz in response to major thermal events.

Table 5

Preliminary estimates of the CMB dipole in the 44 GHz channels.

Table 6

Dipole deflection and correction due to sidelobes.

Table 7

Elements considered in deriving the accuracy of the calibration.

Table 8

Accuracy in the calibration of LFI data.

Table 9

Properties of three compact calibrators used to check the calibration: Orion A (M 42); Cas A; and Tau A (M 1).

Table 10

Average ratio of flux densities for RCA pairs.

Table 11

Visibility times of planets.

Table 12

Averaged brightness temperatures for planetsa. We have applied no correction for planetary disk oblateness.

All Figures

thumbnail Fig. 1

Fourier transforms of the temperatures of the focal plane (Tfp, sensor TS5R) and the back-end (Tbe, sensor R_BEM1) measured during the first three months of data acquisition. Apart from the daily fluctuation induced by the transponder, there are no significant peaks at high frequencies.

In the text
thumbnail Fig. 2

Simulated main meam pattern for beams at the three frequencies: LFI18M (70 GHz, 13.́41 FWHM), LFI24M (44 GHz, 23.́23), and LFI27M (30 GHz, 33.́06). The beams have been calculated using GRASP.

In the text
thumbnail Fig. 3

Results of a simulation which shows how φD is computed. We assume to observe a 1 K peak-to-peak dipole in the sky for 5 minutes with a scanning strategy very similar to the one used for Planck’s 30 GHz radiometers, i.e., the sky is scanned in circles of high amplitude (~85°) with a rotation frequency ν = 1 / 60 Hz and a sampling frequency of 32.5 Hz (so that 10 000 temperature samples are generated for each data stream). We observe the dipole using a realistic 30 GHz beam B = Bmain + Bside with FWHM \hbox{$0\pdeg5$}. Panel A): plot of the (BmainD)(t) term, which oscillates as a sinusoid with amplitude ≲ 0.5 K; the term (BslD)(t) is negligible (see panel C for a close-up). Panel B): plot of the t(BmainD)(t) term, used in the definition of φD (Eq. (9)). Panel C): Close-up of the (BslD)(t) term shown in panel A). Panel D): close-up of the t(BslD)(t) shown in panel B). Panel E): value of φD as a function of time, calculated using the definition in Eq. 9. Panel F): distribution of the 10 000 values of φD plotted in panel E). Half of the values fall within the 0.19–0.34% range.

In the text
thumbnail Fig. 4

Estimated value of φD averaged over the first and second surveys. The central frequencies of the radiometers are 70 GHz for 18M...23S, 44 GHz for 24M...26S, and 30 GHz for 27M...28M. In order to reduce the amount of data to consider, the time-dependent quantity φD was projected on a Healpix map (with NSIDE equal to 64) and binned. The error bars represent the first and third quartiles of the values of the 49 152 pixels in the map, while the middle point is the median.

In the text
thumbnail Fig. 5

Variation in time of a few quantities relevant for calibration, for radiometer LFI21M (70 GHz, left) and LFI27M (30 GHz, right). Vertical dashed lines mark boundaries between complete sky surveys. All temperatures are thermodynamic. Panel A): calibration constant K estimated using the expected amplitude of the CMB dipole. Note that the uncertainty associated with the estimate changes with time, according to the amplitude of the dipole as seen in each ring. Panel B): expected peak-to-peak difference of the dipole signal. The shape of the curve depends on the scanning strategy of Planck (see also Fig. 8), and it is strongly correlated with the uncertainty in the gain constant (see panel A)). The two dots indicate at which time the data used to produce the plots in Fig. 9 were taken. Panel C): 4 K total-power output voltages V. Note that the noise level for V is much more stable than it is for K, as it does not depend on the dipole amplitude. (All the large jumps seen in this figure occurred because of some change in the operational state of the spacecraft; e.g., 456 days after launch we switched off the primary 20 K sorption cooler and turned on the redundant unit.) Panel D): The calibration constants K used to actually calibrate the data for this Planck data release are either derived by applying a smoothing filter to the raw gains in panel A) (70 and 44 GHz, e.g., LFI21M, left), as described in Sect. 3.1, or through Eq. (32) and the 4 K total-power voltages in panel C (30 GHz, e.g., LFI27M, right).

In the text
thumbnail Fig. 6

Schematics of a LFI radiometer. The radiation entering the feed horns in the 20 K front end is split by an OrthoMode transducer (OMT) into its two linearly polarized components. The two signals feed two twin radiometers. (Only one of them is shown in this figure.) The 2.7 K signal is mixed with the signal emitted by a reference blackbody at 4.5 K by an hybrid coupler before being amplified by a Low Noise Amplifier (LNA). A 4096 Hz phase switch induces an alternating 0°/180° phase shift, so that the outputs of the second hybrid are two sequences of sky/reference signals, which both propagate to the warm back-end. Here they are further amplified and measured, before being compressed into packets and sent to Earth. Refer to Mennella et al. (2010) for more details.

In the text
thumbnail Fig. 7

Mask used in the application of Eq. 27 to 30 GHz data (Ecliptic coordinates). The mask hides point sources and the strong emission of the Galactic plane. What is left is that part of the sky where the only significant emissions are the CMB dipole and the CMB itself. Similar masks have been used for 44 and 70 GHz data.

In the text
thumbnail Fig. 8

Top: dipole signal due to the motion of the solar system only (in Ecliptic coordinates). The points observed by LFI27M during pointing periods 4800 (250 days after launch) and 6636 (300 days) are shown with black and blue lines, respectively. (In Fig. 5, panel B on the right, we indicate the times when these two periods occurred with black dots.) Bottom: dipole signal along the same two pointing periods as a function of the North phase angle. Note the difference in the amplitude of the two sinusoidal waves. Such differences are due to the Planck’s scanning strategy and determine the statistical error in the estimation of the calibration constant K = G-1 (Eq. (1)). Refer also to Fig. 9 for details about how K is computed for these two pointing periods.

In the text
thumbnail Fig. 9

The iterative calibration procedure fits the differential voltages with the expected dipolar signal (KCMB), both projected on a map, and it calculates the gain according to Eq. (27). As Fig. 8 shows, depending on the position of the circle with respect to the axis of the dipole signal, the range spanned by the signal can be either large (dipole maximum, top) or small (dipole minimum, bottom). Of course, in the latter case the estimation of the gain suffers from a larger statistical error.

In the text
thumbnail Fig. 10

Variation of the temperature of the back-end with time, as measured by sensor LM207332 (placed near the back-end amplifiers of LFI27M and 27S). The two major thermal events that happened during the period of the nominal mission are clearly visible here: (1) 258 days after launch the transponder antenna switched from a on/off duty cycle of 24 h to being always kept on, and (2) 456 days after launch we switched to the other sorption cooler used to cool the focal plane.

In the text
thumbnail Fig. 11

Difference between the 30 GHz LFI map calibrated using the OSG calibration (Sect. 3.1) and the nominal 30 GHz map (calibrated using the 4 K method, see Sect. 3.2). The residual dipole visible in the map is due only to the latter calibration, as the nominal method removes any residual dipole. A few stripes are visible as well: they are caused by Galactic straylight affecting the fit with the dipole (OSG calibration), as hinted by the fact that such stripes are positive.

In the text
thumbnail Fig. 12

Regression between dipole deflection (arcmin) and dipole amplitude correction ( μK) for each radiometer. Numbers are taken from Table 6. Side arms are in black, main arms are in white and have been shifted by 5 to improve readability.

In the text
thumbnail Fig. 13

Time evolution of the calibration constant used to convert detector voltages into a thermodynamic temperature in Kelvin. The top panel shows the comparison for ADC uncorrected LFI25S-11 diode data between the raw dipole gains (grey dots) and the reciprocal of total-power sky detector voltage (black line), the latter scaled to have the same mean level as the gains. Two highly significant departures can be seen around day 160 and 560 together with lower level variations over most of the time range. The thick dark grey line shows inverse white noise estimates, again scaled to the same gain level, but filtered with a 100 ring moving median filter to reduce the scatter. As expected, this follows the dipole gains. The lower panel shows the same thing, but after the ADC correction has been applied to the TOD data.

In the text
thumbnail Fig. 14

Three degree smoothed map of the difference between the main and side arm of LFI25 before (top) and after (bottom) ADC non-linearity correction. Stripes can seen which are stronger in the region where the solar dipole peaks, as a result of residuals from calibration uncertainties. This relative uncertainty between radiometer arms directly affects polarization as shown here, since the main and side arm difference represents a pseudo-polarization.

In the text
thumbnail Fig. 15

Variation in the average level of the calibration constants of LFI27M, with (black line) or without (grey line) applying the Mademoiselle iterative code, as a function of the error in the solar system speed (top) and the displacement of the dipole axis (bottom). The two plots are normalized so that all the lines go through the point (0,0). The width of the vertical grey band corresponds to the error quoted by Jarosik et al. (2011) for vSun (top) and l (bottom).

In the text
thumbnail Fig. 16

Power spectrum of the simulated artefacts caused by errors in gain reconstruction (see Sect. 5.1), compared with Planck’s best-fit TT power spectrum model.

In the text
thumbnail Fig. 17

Intercomparison of the relative calibration of the LFI radiometers, as measured on the CMB acoustic peak by averaging the power spectrum from 100 < < 250. Note that we display both main arm (slightly to the left of each dotted, vertical line) and side arm (to the right) radiometers for each horn, as they are all calibrated independently. We also include the full frequency maps, labelled as f30, f44, and f70. LFI 70 GHz full frequency at 70% sky coverage is taken as reference.

In the text
thumbnail Fig. 18

LFI cross-spectra between surveys. As in Fig. 17, ratios of the power spectra are computed in the range 50 < < 250.

In the text
thumbnail Fig. 19

Survey difference maps at 30 GHz. Top: difference between survey 1 and 2. Middle: difference between survey 1 and 3. Note that the 12 difference map has sharper features, due to the different scanning strategy between odd and even surveys that prevents optical systematics from being cancelled in the subtraction. Bottom: the mask used to distinguish between CMB-dominated regions and Galactic regions when computing the numbers reported in Table 8 (30 GHz case).

In the text
thumbnail Fig. 20

Spectrum of the half-difference between Sky Survey (SS) 1 and 2, (SS1 − SS2) / 2 (odd-even number surveys, shown in frame A), and (SS1 − SS3) / 2 (odd-odd, frame B), compared with the half ring spectra for the same time period at the three LFI bands. We also show the simulated errors due to gain reconstruction (Sect. 5.1). Spectra have been binned into five samples each, in order to remove high-frequency noise and highlight the general trend. At high multipoles ( > 20) there is a good match between survey differences and half-rings, which means that discrepancies between survey differences are mainly due to statistical noise. Note that the biggest discrepancy between survey differences and halfrings happens for 30 GHz channels when comparing SS1 with SS2 (odd-even); this suggests that optical effects (sidelobes) are causing the discrepancy. Gain errors are calculated over the whole mission and are negligible except for the lowest multipoles of 44 GHz and 70 GHz spectra, where they probably account for the large-scale residuals found in survey difference maps.

In the text
thumbnail Fig. 21

Spectra (left) and per-survey and per-RCA measurements (right) for Orion A (top), Cas A (middle) and Tau A (bottom). For the spectra, the flux densities measured using aperture photometry are shown for LFI and WMAP, as well as the best-fitting power-law to the measurements (solid line) and a ±1% range (dotted line). The fit and data points from Weiland et al. (2011) are shown for Cas A and Orion A, and the Planck Catalogue of Compact Sources (PCCS) flux densities for all three sources are shown. For the per-RCA measurements, RCAs 1823 are at 70 GHz, 2426 at 44 GHz and 2728 at 30 GHz. For each RCA, the average from the three surveys is shown, followed by the measurements from each survey.

In the text
thumbnail Fig. 22

Timeline of planet crossings. Each line shows the times when the planet fell within the beam of at least one of the radiometers at 30, 44, or 70 GHz. Grey bands at the edges mark the start of the survey and the end of the period considered in the 2013 data release. Vertical grey lines mark the separation between sky surveys.

In the text
thumbnail Fig. 23

Jupiter spectrum for LFI compared to the WMAP spectrum (Weiland et al. 2011). Planck data are taken from Table 12. (The LFI points have been rescaled by a factor, 1.0693, which takes Jupiter’s oblateness into account, in order to make them easier to compare with WMAP’s.) The upper frame shows the brightness temperatures as a function of the central wavelength, alongside a simple linear model TJ(λ) = 187.8 K − 4.5 K cm-1λ, which by construction passes through the WMAP’s points at λ = 3.2 mm and λ = 9.1 mm. For both Planck and WMAP, measurement errors are smaller than the size of the symbols. In the bottom frame, we rescaled our points to the linear model in order to better show deviations from it. The error bars for LFI data show the uncertainties quoted in Table 12, as well as the overall calibration errors listed in Table 8.

In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.