Free Access
Issue
A&A
Volume 627, July 2019
Article Number A130
Number of page(s) 18
Section Astrophysical processes
DOI https://doi.org/10.1051/0004-6361/201935490
Published online 12 July 2019

© ESO 2019

1. Introduction

Gravitational-wave astronomy has recently become a reality with the first detection of gravitational waves (GW hereafter) by the Laser Interferometer Gravitational-Wave Observatory (LIGO) and Virgo ground-based interferemeters. To date, eleven events have been reported by the LIGO and Virgo detectors (Abbott 2018), and this number will quickly increase to tens of events in the coming years. Some of these events may correspond to gravitationally lensed events with magnification factors ranging from a few tens to a few hundreds (Dai et al. 2017; Ng et al. 2018; Li et al. 2018a; Smith et al. 2018a,b; Broadhurst et al. 2019). Recent works have studied lensing effects in the existing LIGO/Virgo O1 and O2 events (Hannuksela et al. 2019; Broadhurst et al. 2019), while Smith et al. (2018c) searched for candidate galaxy cluster lenses for the GW170814 event. The most likely lenses for such events would be massive galaxies or galaxy clusters (Ng et al. 2018; Dai et al. 2017; Smith et al. 2018b; Broadhurst et al. 2019). On the other extreme of the lens mass regime, compact objects with masses of a few hundreds to a few tens M can also act as lenses (Lai et al. 2018). In this case, the geometric optics limit is not valid since the Schwarszchild radius of the lens is comparable to the wavelength of the wave. For these relatively low masses, the lensing effect has a modest impact on the average magnification, but it can introduce a frequency dependence on the magnification (see for instance, Jung & Shin 2019; Lai et al. 2018). An even smaller mass regime was considered in Christian et al. (2018) where the authors find that lenses with a mass as low as 30 M could be detected with current experiments. They also consider future, higher-sensitivity experiments and show how they can push the limit to even smaller masses of order 1 M. These conclusions are, however, obtained assuming isolated microlenses and without accounting for the effect of the macromodel, or other nearby microlenses. In the small mass regime, microlenses such as neutron stars have been also considered as scattering sources of GWs, and it is found that a GW can be focussed at a focal point near the neutron star surface (Halder et al. 2019; Stratton & Dolan 2019).

The signal-to-noise (S/N) of and observed GW that is being lensed with magnification μ scales (to first order) as S / N μ / D l ( z ) $ S/N\,{\sim}\,\sqrt{\mu}/D_{\mathrm{l}}(z) $, where Dl(z) is the luminosity distance to the GW source at redshift z. If we denote by Dm as the maximum luminosity distance at which a GW with a given chirp mass can be observed (that is, with S/N equal to the minimum S/N for detections, S/Nmin), then the S/N of a wave that originates at this maximum distance (or equivalenty at the maximum redshift zm) and that is magnified by a factor μ would be equal to S / N min μ D m / D l ( z ) $ S/N_{\mathrm{min}}\sqrt{\mu}D_{\mathrm{m}}/D_{\mathrm{l}}(z) $. It then follows that an event with magnification μ can be observed up to a maximum luminosity distance D l ( z ) = μ D m $ D_{\mathrm{l}}(z)=\sqrt{\mu}D_{\mathrm{m}} $. Even for a modest value of μ ≈ 4, the volume from which GWs can be observed would increase by almost one order of magnitude.

For low redshifts of the GW, the probability of lensing is low. This probability is often referred to as the optical depth of lensing, τ, and to first order it can be interpreted as the integrated (over the mass function of lenses) cross-section of all gravitational lenses from redshift 0 to the redshift of the source. In the simplest calculations, the cross-section of an individual lens is given simply by its Einstein radius. A more detailed calculation of the optical depth incorporates the profiles of the lenses as well as their ellipticity and computes the probability of lensing in the source plane by inverse ray shooting techniques (see for instance Diego 2019).

Independently of the models assumed for the lenses, the optical depth is found to increase quickly between source redshift 0 and source redshift 1. Beyond redshift 1, the optical depth keeps increasing but at a slower pace, and beyond redshift ≈3 the increase in optical depth is only at the percent level compared with the optical depth for a source at z = 3. Hence, one would expect gravitational lensing of GW to be more much common for sources beyond z = 1 than for sources below z = 1. As an example, the optical depth for magnification factors μ >  4 and for sources at redshift z = 2 is found to be around 10−4 (see for instance Turner et al. 1984; Fukugita et al. 1992; Kochanek 1996; Hilbert et al. 2008; Takahashi et al. 2011; Diego 2019), meaning that approximately 1 in 10 000 GWs at z = 2 would be magnified by a factor μ >  4. If one considers a spherical shell of thickness δz = 0.2 around z = 2, one finds a volume of ≈100 Gpc3. If one considers the local rate of binary vlack holes (BBH) inferred by LIGO (≈200 Gpc−3 yr−1) and extrapolates this rate to z = 2 assuming an evolution model that follows the star formation rate (that is, a rate of factor ≈4 times larger at z = 2 than at z = 0, Madau & Dickinson 2014), one finds that, in the shell volume considered above, there is approximately 105 events per year, out of which around 10 events would be amplified by a factor μ >  4 (some of these events will be observed several times, thus increasing the number of detections). Ng et al. (2018) finds estimates for the number of detectable lensed events, arriving at a total of ∼1 − 100 lensed events per year at the LIGO design sensitivity limit. An experiment that has the sensitivity to detect unlensed events up to z = 1, could potentially detect these lensed events at z >  2. Future studies will be able to estimate the number of these types of lensed events more accurately.

The next observing runs will see further sensitivity upgrades to both LIGO and Virgo, as well as the prospects of a fourth detector called KAGRA (Somiya 2012; Aso et al. 2013; Akutsu et al. 2018) joining the network. Simultaneously, another detector is being built in India (Iyer et al. 2011). As the sensitivities of these ground-based detectors improve in the near future, GW experiments will reach the z = 1 frontier, opening the door to study lensed GW events. These lensed events will be interesting for multiple reasons. The most obvious one is that they will allow to extend the range of redshift at which GWs can be detected and set strong constraints on the evolution of events as a function of redshift (the number of observed lensed events is proportional to the unknown rate at high redshift times the known optical depth of lensing). As interesting as this might be, this paper focuses on a different aspect. GWs that are lensed by factors larger than a few, will inevitably travel through areas near the critical curves of the lenses. The size of these critical curves normally trace the distribution of matter of the lenses in regions where the convergence is ≈0.5 − 0.8. At these convergence values, the presence of numerous microlenses along the path of the GW is not only possible but unavoidable (see for instance Diego et al. 2018). These microlenses can be stars and remnants from the galaxy or intracluster medium but also more exotic microlenses such as the hypothesized primordial black holes (PBH). Although numerous studies show that PBH can not account for all dark matter, in the mass regime of a few tens of solar masses, PBH can still account for a few percent of the total mass budget. Even a small fraction of dark matter in the form of PBH could account for the rate of binary black hole merger observed by LIGO/Virgo (see for instance Carr et al. 2017; Liu et al. 2018, 2019; Chen & Huang 2018; Raidal et al. 2019). Whether or not LIGO/Virgo is observing a population of PBH with masses around 30 M is still an open question. Microlensing can severely constrain the fraction of PBH in the universe (see for instance Diego et al. 2018; Oguri et al. 2018). Microlenses can introduce a modulation in the magnification of the GW as a function of frequency (Deguchi & Watson 1986; Nakamura 1998; Takahashi & Nakamura 2003). Earlier work has suggested that microlenses with masses below 100 M can not produce observable effects in GWs observed by LIGO/Virgo (see however Christian et al. 2018, where the authors claim LIGO/Virgo could detect masses as small as 30 M if the signal to noise ratio is at least a factor 30). One of the reasons for this is due to the very small time delay between images produced by microlenses in this mass range. Such time delays are much smaller than the inverse of the frequency of the GWs observed by LIGO/Virgo, so no observable interference is produced at frequencies below 500 Hz. We argue that this is not necessarily the case and that in certain configurations, GWs can be significantly affected by microlenses down to ≈1 M.

Although microlenses have been considered in the context of GW, they are often considered as isolated point sources. This is certainly not the case when dealing with microlenses at cosmological distances and near critical curves1. Instead, microlenses are always embedded in the potential of the macrolens (galaxy or cluster) they belong to. The effect of the macromodel can not be ignored as it can have a significant impact on the observed lensing signal. For instance, a point lens with no external shear will reduce its caustic to a single point and will produce only two counterimages. On the contrary, a microlens with an external shear will have a diamond shape caustic and typically produces 3 images. In the context of GWs, having two or three images can make a significant difference since the interference pattern can change substantially (two time delays instead of one). Moreover, when approaching the critical curve of a lens (that is, at larger magnification factors μ), a fixed unit of area in the image plane gets compressed in the source plane by a factor μ. This has important implications for the lensing of GWs. A large compression factor (i.e.,a large μ) can result in overlapping microcaustics in the source plane (see for instance Kayser et al. 1986; Paczynski 1986; Wambsganss et al. 1990; Wyithe & Turner 2001; Kochanek 2004; Diego et al. 2018; Diego 2019). These overlapping microcaustics can produce images that are separated by relatively large distances in the image plane, or in other words, can produce images with relative geometric time delays which are larger than the time delays they would produce without overlap. If the time delay between two lensed waves is of the order of the inverse of the frequency of the GW, both waves interfere and the observed signal could show this interference. In this paper we explore the regime of GWs magnified by a macromodel in the presence of microlenses with stellar masses.

The structure of this paper is as follows. In Sect. 2 we present the basic lensing formalism that is relevant for this paper (geometric optics limit). Section 3 discusses the magnification when the geometric optics limit is not valid and one needs to consider wave optics. In Sect. 4 we discuss the algorithm used to compute the magnification in the wave optics regime and tests the algorithm performance with a simple example for which an exact analytical solution exists in Sect. 5. In Sects. 68 we present examples of magnifications as a function of GW frequency for a range of examples. Each section increases the degree of complexity of the microlens model. Section 6 starts with the simple case of a single microlens embedded in a macromodel potential. Section 7 considers the particular case of two microlenses (with overlapping caustics), and with masses comparable to the massive black holes of the primaries that are being found by LIGO/Virgo. Section 8 considers the realistic case of a population of microlenses with stellar masses but that are near a critical curve region, that is, it addresses the question of what is the role of microlenses in GW lensed events at large magnification factors. Finally, we discuss our results and conclude in Sect. 10. In all cases, and without loss of generality, we assume a standard cosmological model with Ωm = 0.3, Λ = 0.7 and h = 0.7 consistent with the latest constraints on the cosmological model from Planck. We also assume that the GWs originate at z = 2 and that the microlenses (and macrolens) are at z = 0.5. Our results depend weakly on these assumptions provided the lens is at cosmological distances and the GWs are at least twice that distance.

2. Deflection field for microlenses in macromodel potentials

In this section we briefly review the lensing formalism for microlenses embedded in a macromodel potential (a host galaxy or galaxy cluster). This topic has been widely covered in the literature (Chang & Refsdal 1979, 1984; Kayser et al. 1986; Paczynski 1986). For simplicity, we define the macromodel with just two parameters, the macromodel magnification factors in the radial and tangential direction, or μr and μt respectively. This simple choice for the macromodel is sufficient for our purpose since we are dealing with very small regions of the sky where the changes in the macromodel properties are insignificant. Without loss of generality, we assume that μt ≫ μr and that the main direction of the shear, γ, is oriented in the horizontal direction, that is γ2 = 0 and γ = γ 1 2 + γ 2 2 = γ 1 $ \gamma=\sqrt{\gamma_1^2 + \gamma_2^2}=\gamma_1 $. Given μt and μr, the corresponding values of κ (convergence) and γ (shear) can be found easily from the relation between κ, γ, μr and μt. For a given choice of κ, and γ, the lens equation (β = θ − α(θ)) of the macromodel can be expressed as

β = θ α ( θ ) = ( 1 κ γ 1 γ 2 γ 2 1 κ + γ 1 ) θ , $$ \begin{aligned} \boldsymbol{\beta }= \boldsymbol{\theta } - \boldsymbol{\alpha }(\boldsymbol{\theta }) = \begin{pmatrix} 1-\kappa -\gamma _1&-\gamma _2 \\ -\gamma _2&1-\kappa +\gamma _1 \end{pmatrix} \boldsymbol{\theta }, \end{aligned} $$(1)

where the positions in the source plane are given by the coordinates β = (βx, βy) and the positions in the image plane are given by the coordinates θ = (θx, θy).

The lensing potential of the macromodel, ψ, is given by

ψ = κ 2 ( θ x 2 + θ y 2 ) + γ 1 2 ( θ x 2 θ y 2 ) γ 2 θ x θ y = κ 2 ( θ x 2 + θ y 2 ) + γ 2 ( θ x 2 θ y 2 ) $$ \begin{aligned} \psi =\frac{\kappa }{2}(\theta _x^2 + \theta _{ y}^2) + \frac{\gamma _1}{2}(\theta _x^2 - \theta _{ y}^2) - \gamma _2\theta _x\theta _{ y} = \frac{\kappa }{2}(\theta _x^2 + \theta _{ y}^2) + \frac{\gamma }{2}(\theta _x^2 - \theta _{ y}^2) \end{aligned} $$(2)

where we remind the reader that we adopt a reference system where γ2 = 0, θx and θy are given in radians, and we ignore a constant additive term (i.e., the potential is identically zero at the origin of coordinates of θ).

Since both the deflection field and lensing potential are linear with the addition of new masses, if a population of N point masses are present, the deflection, αPS(θ), and potential, ψPS(θ), from the distribution of point masses can be simply added to the above equations with;

α PS ( θ ) = i N 4 G M i D i ( z l , z s ) c 2 δ θ i | δ θ i | 2 , $$ \begin{aligned} \boldsymbol{\alpha }_{PS}(\boldsymbol{\theta })=\sum _i^N\frac{4GM_iD_i(z_{\rm l},z_{\rm s})}{c^2}\frac{\delta \boldsymbol{\theta }_i}{|\delta \boldsymbol{\theta }_i|^2}, \end{aligned} $$(3)

and,

ψ PS ( θ ) = i N 4 G M i D i ( z l , z s ) c 2 l n ( | δ θ i | ) , $$ \begin{aligned} \psi _{PS}(\boldsymbol{\theta })=\sum _i^N\frac{4GM_iD_i(z_{\rm l},z_{\rm s})}{c^2}ln(|\delta \boldsymbol{\theta _i}|), \end{aligned} $$(4)

where δ θi = θ − θi is the distance to the point mass i at θi and with mass Mi, Di(zl, zs) is the geometric factor Di(zl, zs)=Dls(zl, zs)/(Dl(zl)Ds(zs)) with Dls(zl, zs), Dl(zl) and Ds(zs) the angular diameter distances between the lens and the source, between the observer and the lens, and between the observer and the source respectively.

A quantity of interest, that will be relevant in Sect. 8, is the effective optical depth, τeff introduced by Diego et al. (2018),

τ eff = ( 4.2 × 10 4 ) Σ μ μ r $$ \begin{aligned} \tau _{\rm eff}=(4.2\times 10^{-4})\Sigma \frac{\mu }{\mu _{\rm r}} \end{aligned} $$(5)

where the total magnification (μ) is the product of the tangential and radial magnifications (i.e., μ = μt × μr), and Σ (expressed in units of M pc−2 in the expression above) is the microlens surface mass density. When τeff ≈ 1, the saturation regime is reached. In this regime, caustics constantly overlap in the source plane, and any source moving across a field with τeff >  1 will always be experiencing microlensing (Diego et al. 2018; Diego 2019). Since typical values for Σ(M pc−2) range between a few to a few tens, and assuming a typical value for μr  ∼  1, it is clear from the expression above, that the saturation regime is reached when the macromodel magnification is in the range of a few hundred to a few thousand. Similar values for the macromodel magnification have been observed already at the position of the microlensing events of the Icarus and Warhol high redshift stars (Kelly et al. 2018; Chen et al. 2019). Given the fact that GW experiments have access to the entire sky at any given moment (as opposed to the aforementioned examples of Icarus and Warhol where a significant luck-factor had to be involved) events with similar, or even more extreme, macromodel magnifications are expected (see Diego 2019, for a detailed estimation of the probability of these events). In those scenarios, we expect microlensing to play a significant role.

Finally, the time delay is given by

Δ T = 1 + z l c D ( z l , z s ) [ 1 2 | θ β | 2 ψ ] = Δ T geom + Δ T grav $$ \begin{aligned} \Delta T = \frac{1+z_{\rm l}}{cD(z_{\rm l},z_{\rm s})}\left[ \frac{1}{2}|\boldsymbol{\theta }-\boldsymbol{\beta }|^2 - \psi \right] = \Delta T_{\rm geom} + \Delta T_{\rm grav} \end{aligned} $$(6)

where we have assumed that all point masses are at the same redshift in the lens plane so the factors Di(zl, zs) are the same for all of them. The term ΔTgeom is known as the geometric time delay and the term ΔTgrav is known as the gravitational time delay.

Equation (6) is useful to understand how the superposition of microlenses affect the time delays. From Eq. (2) and Eq. (4), the addition of several microlenses at positions θi results into multiple locations in the vicinity of each θi where the derivative of Eq. (6) vanishes (i.e., where microimages form). Understanding the effect of the superposition of microlenses over the time delay is not trivial, since different competing effects are at play. To illustrate the different effects, we show in Fig. 1 a simple one-dimensional example involving three microlenses at positions (θi), A, B and C. The source is placed in position 5 and, for easier comparison, all time delay curves have the minimum time subtracted. The dashed lines show the time delays if only one of the microlenses is considered at a a time. Microimages appear at the positions where the derivative of the time delay is zero. The magnification of the microimages is inversely proportional to the curvature of the time delay curve. From the figure, it is clear that the image that arrives first (see dashed lines at time T = 0 and position P ≈ 4) is also the microimage with the largest magnification. Since C is the farthest from the source position, it results in the largest time delay (red dashed line) with a maximum time delay of T ≈ 8 at position P ≈ 8. If we compare the time delays of A (or B) and A+B, we observe how the maximum time delay is ≈3 times larger in the A+B case (compare the maximum time delay for the yellow dashed line at T ≈ 3 and P ≈ 7 with the maximum time delay for the solid yellow line at T ≈ 10 and P ≈ 6). However, the magnification of the macroimage with the largest time delay in the case of A+B (at P ≈ 5.75) is relatively small. The two dominant microimages in the case A+B, and at positions P ≈ 3.5 and P ≈ 7.5, have a relative time delay which is also larger than the time delay in cases A or B, but the increase in time delay is in this case more modest. The two dominant microimages in case A+B can be reinterpreted as the two counterimages of a single and larger microlens at an intermediate position between A and B, but with the total mass of A and B. The microimages are separated by a larger angular distance (i.e., the system A+B behaves as a microlens having a larger mass) and the time delay would be larger (due to the increased combined mass of the microlens). The situation is different if one considers microlenses that are separated by larger distances. Let us now consider the case A+C (solid red curve). Here we observe that the maximum time delay is now smaller than the maximum time delay of case C (dashed red curve). In this case, the addition of the microlens A to C does not help to increase the time delay, but it does increase the complexity of the time delay structure due to appearance of a third new microimage (with substantial magnification) at position P ≈ 6.5 and different time delay. If one finally considers the case A+B+C (solid blue curve), a large time delay of T ≈ 12 is present in the small microimage at position P ≈ 5.75. The second largest time delay at P ≈ 6.75 is also larger than the maximum time delay that would have been observed in cases A, B or C. It is difficult to generalize since the distribution of time delays depends on too many factors (macromodel magnification, number of microlenses, mass of microlenses, relative separations of the microlenses, and source position at the very least) but as a general rule, it should be clear that microlenses that are close enough to each other can work together to mimic the effect of a larger microlens (hence introducing larger time delays) and also overlapping microcaustics increase the number of multiple microimages and consequently the number of time delays.

thumbnail Fig. 1.

Time delay in one dimension with two and three microlenses. The microlenses are at positions A, B, and C. The dashed lines show the time delay when only one of the three microlenses is considered. The solid lines corresponds to the time delay when two or three microlenses are considered. Microimages form around the positions where the derivative of the time delay equals zero. The magnification of each microimage is inversely proportional to the curvature (i.e., second derivatives) of the time delay around these positions.

It is sometimes useful to express the time delay in dimensionless units. Usually this is done by re-scaling both the angular positions and potential by the Einstein radius, θ E 2 =(4GM/ c 2 )D( z l , z s ) $ \theta_E^2=(4GM/c^2)D(z_{\rm l},z_{\rm s}) $. This redefinition of the time delay expression makes most sense when one is dealing with a single microlens since in this case the Einstein radius can be defined without ambiguity, but in general one can still set the Einstein radius to any arbitrary mass, or scale, and still redefine the time delay equation.

Δ T = 4 G M ( 1 + z l ) c 3 [ 1 2 | x y | 2 ψ ] = 2 R s ( z l ) c [ 1 2 | x y | 2 ψ ] , $$ \begin{aligned} \Delta T = \frac{4GM(1+z_{\rm l})}{c^3}\left[ \frac{1}{2}|\boldsymbol{x}-\boldsymbol{y}|^2 - \tilde{\psi } \right] = \frac{2R_s(z_{\rm l})}{c}\left[ \frac{1}{2}|\boldsymbol{x}-\boldsymbol{y}|^2 - \tilde{\psi } \right], \end{aligned} $$(7)

where x = θ/θE, y = β/θE, ψ = ψ / θ E 2 $ \tilde{\psi}=\psi/\theta_E^2 $, and Rs(zl) is the redshifted Schwarzschild radius of the lens. The first term sets the scale of the time delay for a given lens mass, 4GM/c3 = 1.97 × 10−5 (M/M) seconds. This simple scaling, shows that for GW with frequencies ν ∼ 100 Hz, interference and diffraction effects are expected for isolated microlenses with masses > 500/(1 + zl) M. Below this mass, the Schwarzschild radius of the lens is smaller than the wavelength of the GW (with ν ∼ 100 Hz) and diffraction effects are not important resulting in the GW not seeing the microlens. However, as discussed in the sections below, this minimum mass can be lowered substantially under certain conditions that can increase the time delay between multiple images.

3. Lensing of gravitational waves at large macromodel magnifications

Lensing of GW has been studied in detail in the past (Wang et al. 1996; Nakamura 1998; Sereno et al. 2010) and more recently in Dai et al. (2017, 2018), Jung & Shin (2019), Broadhurst et al. (2018), Lai et al. (2018), Christian et al. (2018), Oguri (2018), Smith et al. (2018a). In a broader sense, extensive work has been done in the context of wave optics, which is the appropriate regime for studying the lensing of GWs when the Schwarschild radius of the lens is comparable to the wavelength of the GW (Nakamura 1998; Nakamura & Deguchi 1999; Takahashi & Nakamura 2003). Also, in the context of astrophysics, femtolensing is formally identical to lensing of GWs but at much higher frequency, and hence, involving much smaller microlenses (Ulmer & Goodman 1995). Finally, the wave optics regime is covered also in traditional textbooks like for instance Schneider et al. (1992). This section presents only a brief description of the formalism that is relevant for this paper. The reader is directed to the above literature for more details.

When a GW is amplified by a factor μ, the observed S/N increases by a factor μ $ \sqrt{\mu} $. If the Schwarzschild radius of the lens is much larger than the wavelength of the GW, geometric optics can be applied and the observed strain gets amplified by the same factor μ $ \sqrt{\mu} $ independently of the varying GW frequency. However, when the wavelength of the GW is comparable to the Schwarzschild radius of the lens, interference between multiply lensed GWs can take place, since in this case the time delay between GWs is comparable to the inverse of the frequency of the GW. (Strictly speaking, in the linear optics regime two waves can still interfere but with a phase difference between the two waves that is stationary. The result would be a wave with different amplitude but the same frequency, i.e., without an obvious sign of interference.) In this regime, one needs to consider wave optics and the magnification factor may be significantly different several cycles before the merging event and right before the merger event (e.g., Takahashi & Nakamura 2003). This would introduce a modulation in the observed strain as a function of time that can be measured and used to infer the masses of the intervening lens (Cao et al. 2014; Lai et al. 2018). Interference produced by multiply lensed images has been studied in detail in the literature. In the context of LIGO/Virgo observations, the mass of the lenses considered in earlier work is typically above 100 M (see however Christian et al. 2018). At smaller masses, isolated microlenses can produce time delays that are very small (much smaller than the inverse of the frequency of the GW) so interference does not take place. Also, much of the earlier work has studied the case of isolated microlenses (i.e., with circular critical curves and point-like caustics), or at most microlenses with an external shear of moderate strength (Lai et al. 2018). To the best of our knowledge, no work has considered the case of multiple microlenses nor the regime where the potential from the macromodel can produce large magnification factors. Both scenarios can produce interesting effects that can be observed at LIGO frequencies. Large magnification factors are expected for observed GWs originating at redshift z >  1. As discussed in Broadhurst et al. (2018), observed lensed GW events are expected at large magnification factors (tens to few hundreds) for some models. A distribution of microlenses with stellar masses (mass ∼1 M) can produce overlapping caustics in the source plane. An event taking place inside one of these overlapping regions would appear in the image plane at separations similar to the separation between the microlenses. For instance, if two overlapping microcaustics originate from two microlenses with stellar masses but separated by several microarcsec, they could mimic the separation between microimages produced by a much larger microlens. Also, even for isolated microlenses, a large macromodel magnification can introduce a large geometric time delay, so even moderate masses can produce measurable interference effects. More precisely, a microlens with mass M embedded in a macromodel with magnification μ behaves like a microlens with an effective mass Mμ (Diego et al. 2018; Diego 2019).

In the context of lensing of GWs, this effect was first discussed in Lai et al. (2018). This issue was discussed later in more detail in Diego (2019), which showed how for a fixed source position, the time delay increases with the macromodel magnification. In Fig. 2 we illustrate this behavior with a 100 M microlens at two different macromodel magnifications, and for a fixed source position. For the same source position (relative to the projected position of the microlens) the time delay between the two dominant microimages is larger by a factor 4 $ {\approx}\sqrt{4} $. We note how the factor 4 is the ratio of the two macromodel magnifications. This scaling was first noted by Diego et al. (2018), where it is discussed how a microlens with mass M embedded in a macromodel potential with magnifcation μ behaves as a microlens with effective mass, Meff = μM. Then, the time delay scales also with the effective mass of the microlens.

thumbnail Fig. 2.

Microlensing by a 100 M star at two different macromodel magnifications of 15 (μt = 5 and μr = 3, left) and 60 (μt = 20 and μr = 3, right). The field of view is the same in both cases. In each case, the larger panel shows the magnification in the lens plane (critical curve) while the small panel in the bottom-right corner shows the corresponding magnification in the source plane (caustic). The small white dot inside the caustic marks the position of the source. The numbers in the larger panels indicate the magnification of each microimage and the corresponding time delays (in milliseconds) relative to the image that arrives first (marked with 0 ms). The separation between the source and the projected position of the microlens is the same in both cases. We note how at larger macromodel magnifications, both the time delays and the area enclosed by the caustic (i.e., the probability of microlensing) are larger.

The increase in relative time delay (between two microimages) with the macromodel magnification can be understood if we look at Eqs. (2) and (6). For simplicity, we consider the time delay along the line connecting the two microimages (around a microlens with lensing potential ∝Mlog(|θ − θo|) where M is the mass and θo the position of the microlens). For convenience we adopt a reference system where this line contains the microlens, it is horizontal (θy = 0), and we consider a macroimage with positive parity, i.e.,(κ + γ) < 1. From Eq. (2), the potential is (κ + γ)θ2/2 after taking the one dimensional potential along the direction θy = 0. The change in potential is very smooth and, in the vicinity of the counterimages, it can be approximated by a gradient with slope (κ + γ). Then, from Eq. (6), the time delay between the two counterimages will be larger as one approaches the critical curve, since the slope of the gradient, (κ + γ) will be larger, thus increasing the relative difference between the two local minima in the time delay curve. Also, the larger gradient results in a greater angular separation between the microimages and a time delay surface with smaller curvature around the minima of the time delay (i.e., with a larger magnification). This is similar to the effect described in earlier work, where the effect of the macromodel with magnification μ over a microlens can be interpreted as an increase in the effective mass of the microlens by a factor μ, thus increasing the typical angular separation, and relative time delay, between microimages (Diego et al. 2018).

The magnification factor in wave optics is given by the diffraction integral (see for instance Schneider et al. 1992).

F ( w , β ) = A o ν 2 π i d 2 θ e i 2 π ν Δ T ( θ , β ) $$ \begin{aligned} F({ w}, \beta ) = A_o \frac{\nu }{2\pi i} \int d^2\theta \, e^{i2\pi \nu \Delta T(\theta ,\beta )} \end{aligned} $$(8)

where ν is the frequency of the GW in Hz and the normalization Ao guarantees that at very high frequencies one recovers the geometric optics magnification when averaged over a frequency range. ΔT is the time delay between lensed images expressed in seconds. The total magnification, μ, and phase shift, ϕ, are given by (see for instance Takahashi & Nakamura 2003)

μ = | F ( w , β ) | 2 , $$ \begin{aligned} \mu = |F({ w},\beta )|^2, \end{aligned} $$(9)

ϕ = i ln ( F ( w , β ) | F ( w , β ) | ) . $$ \begin{aligned} \phi = -i \ln \left( \frac{F({ w},\beta )}{|F({ w},\beta )|}\right). \end{aligned} $$(10)

For simple models, like for instance an isolated point-like microlens, simple expressions for ΔT can be found and Eq. (8) can be evaluated analytically, yielding (Nakamura 1998; Takahashi & Nakamura 2003):

F ( w , y ) = e h ( w , y ) Γ ( 1 i w 2 ) 1 F 1 ( i w 2 , 1 ; i wy 2 2 ) $$ \begin{aligned} F({ w},{ y}) = e^{h({ w},{ y})}\,\Gamma \left(1-i\frac{{ w}}{2}\right)\, _1F_1\left( i\frac{{ w}}{2},1;i\frac{{ wy}^2}{2} \right) \end{aligned} $$(11)

where we remind the reader that y = β/θE and w = (8πGM(1 + zl)/c3)ν. The function Γ is the standard gamma function and 1F1(a, b; z) is the Kummer’s confluent hypergeometric function of the first kind. The term in the exponential part is given by:

h ( w , y ) = π w 4 + i w 2 [ ln ( w 2 ) ( Y 2 + 4 Y ) 2 4 + ln ( Y 2 + 4 + Y 2 ) ] $$ \begin{aligned} h({ w},{ y}) = \frac{\pi { w}}{4}+i\frac{{ w}}{2}\left[ \mathrm{ln}\left(\frac{{ w}}{2} \right) - \frac{\left( \sqrt{Y^2+4}-Y \right)^2}{4} + \mathrm{ln}\left(\frac{\sqrt{Y^2+4}+Y}{2}\right) \right] \end{aligned} $$(12)

where y = βθE.

When multiple microlenses are present, the time delay between multiple images can adopt a complex form. However, the integral can still be solved numerically as described in the next section.

4. Numerical evaluation of the observed magnifications

To evaluate Eq. (8) in a general situation, we follow Ulmer & Goodman (1995). The basic idea is to divide the integral in Eq. (8) in areas of equal time delay. Then it is easy to see that Eq. (8) is equivalent to computing the Fourier transform of FT), where FT) accounts for the area with a given time delay, ΔT. For simplicity, we rename FT)=F(t). In Ulmer & Goodman (1995), the authors propose an algorithm where F(t) is computed as contour integrals. While that is a valid approach, we use the simpler, and faster, method of computing directly the area in constant intervals of ΔT.

F ( t ) = d x d y δ ( Δ T ( x , y ) t ) . $$ \begin{aligned} F(t)=\int \mathrm{d}x\mathrm{d}{ y} \delta (\Delta T(x,{ y})-t). \end{aligned} $$(13)

This method avoids also the divergence of the contour integrals at the local minima and maxima of the time delay function. Finally, the direct computation of the area from the time delay maps is equally time consuming for one, or many, microlenses, something that is not true for the countour integral method which first needs to identify contours around each microlens and later perform the contour integral along each contour.

5. Testing the performance of the numerical method with isolated point masses

To test the validity of the numerical approximation, we compute the lensing magnification as a function of the GW frequency for the particular case of an isolated microlens. For this case, an exact solution exists and it is given by Eq. (11). We simulate the deflection field around a microlens with mass 100 M at redshift z = 0.5. We place a source at redshift z = 2 and at distances 0.05 and 0.1 times the Einstein radius of the lens (that is, Y = β/θ = 0.05 and Y = 0.1 in Eq. (11)). For each configuration, we compute the time delay and derive the function F(t).

These are shown in Fig. 3. The blue curve is for the case where Y = 0.05 while the red curve is for Y = 0.1. In both cases, the curves are normalized to 1 at large time delays. This is equivalent to dividing by the not-lensed signal, for which the corresponding F(t) would be a constant. The F(t) curves converge to the no-microlensing case at large time delays (that is, F(t)=Cte) and exhibit a logarithmic pulse at the corresponding time delay between the two counterimages (the logarithmic shape is discussed in more detail in Ulmer & Goodman 1995).

thumbnail Fig. 3.

Function F(t) for an isolated point mass with 100 M and at a distance from the singular caustic Y = βE = 0.05 (blue solid line) and Y = 0.1 (red solid line). Both curves are normalized to 1 at large time delays.

The amplitude of the logarithmic pulse is related with the magnification. As expected, the case with Y = 0.05 has larger magnification but smaller time delay between the images than the case with Y = 0.1. Fourier transforming back the F(t) curves, and multiplying by the frequency one obtains the corresponding F(w) (Ulmer & Goodman 1995; Nakamura & Deguchi 1999). In order to correct for the limited time span covered by F(t), we apply an apodization (in real space) at large time delays to the curve F(t). Without this apodization, the magnification at low frequencies (ν <  100 Hz) tends to zero. We find that a standard cosine apodization function works remarkably well. The result is shown in Fig. 4. The dashed lines show the results derived with the exact calculation. Again, the case with Y = 0.05 attains larger magnifications than the case with 0.1. In both cases, the average (over a wide range of frequencies) of the magnification converges to the magnification predicted by geometric optics. At low frequencies, both curves converge to 1 as expected since the corresponding wavelengths become smaller than the Schwarzschild radius of the lens. The dotted lines show the numerical approximation. The numerical approximation reproduces very well the exact solution with deviations at the sub-percent level. At low frequencies, the GW does not see the microlens and the magnification tends to one.

thumbnail Fig. 4.

Predicted magnification for an isolated point mass with 100 M and at a distance from the singular caustic Y = βE = 0.05 (blue lines) and Y = 0.1 (red lines). The dashed lines show the analytical (exact) prediction. The dotted lines show the result obtained with the numerical algorithm.

6. Microlens embedded in a macromodel potential

In the previous section we showed the result for an isolated lens and compared it with the analytical exact solution. That situation is unrealistic in the sense that most microlenses will be forming part of a halo (galaxy, group of galaxies or cluster). This halo, or macromodel, imprints a magnification in the GW which is generally insensitive to the frequency of the GW. That is, the effect of the macromodel over the GW can be treated in the geometric optics limit since the Schwarzschild radius of the halo is orders of magnitude larger than the wavelength of the GW. For simplicity, we assume that the macromodel forms two counterimages. Although in most situations, a macromodel will form more than two images, usually two of them carry the bulk of the magnification and will be the most likely to be observed if the merger occurs at large redshift. However, our results can be applied to any of the counterimages. As mentioned above, these two macroimages can be treated in the geometric optics limit. We neglect here the very particular (and extremely rare) case where the final moments of the inspiral phase takes place very close (thousands of km) to one of the caustics of the macro-model. In this case, diffraction effects from the macromodel become also important and the geometric optics limit is no longer valid. This case is studied in the literature (see for instance Schneider et al. 1992, and references therein). Usually, the two counterimages with the largest magnification have opposite parity. From now on, we refer to the counterimages produced by the macromodel as macroimages and we distinguish between the macroimage with positive parity and the macroimage with negative parity. The images produced by the microlens are referred to as microimages. If a macroimage intersects a microlens, the macroimage will, in general, break into multiple microimages. A macroimage with positive parity will break into microimages with both positive and negative parity. The situation is similar for macroimages with negative parity.

6.1. Magnification

Before studying the interference pattern produced by the multiple microimages, it is illustrative to visualize the configuration of microimages in the geometric optics limit. To simulate microlenses in an external shear we follow Diego et al. (2018). For the macromodel, we adopt the values μt = 10 and μr = 3, which results in a net magnification of μ = 30. In general, the macromodel can impact substantially how the magnification behaves around a microlens. The only case where the effect of the macromodel on the microlenses can be safely ignored is for microlenses in the Milky Way but we do not treat this case here. Our focus is instead for microlenses in galaxies, groups or clusters at cosmological distances and GWs produced at redshifts of 1 or above. The caustic of a point-like microlens in the presence of an external shear (from the macromodel) is no longer a point but it adopts the familiar diamond shape typical of elliptical lenses if the microlens is on the side of the macromodel where images have positive parity (i.e., in a macrominima or macromaxima of the time delay). An example is shown in the left panel of Fig. 5. The critical curves adopt the typical elongated shape of elliptical potentials. The small inset in the bottom-right corner shows the corresponding caustic in the source plane. The location of two sources are marked with a white dot inside the caustic region and a yellow dot outside the caustic region. The number next to each source indicates the magnification in the source plane. The corresponding counterimages for each source are shown in the image plane (larger plot). For each microimage, we indicate the magnification in the image plane and the time delay (in milliseconds) with respect to the minimum of the time delay. The yellow microimages are shown with their approximate size and orientation. In the absence of microlens, the macromodel magnification would be 30. When the microlens is introduced, the white source is magnified by almost a factor two times larger. The yellow source, on the other hand, has a magnification comparable to that of the macromodel. In the wave optics regime, the time delay between microimages plays an important role and can leave an observational imprints, even for groups of microimages that are unresolved. At time delays of order few millisecond, GW as those observed by LIGO/Virgo would interfere. As expected, the relative time delay between microimages near a critical curve is relatively short (0.24 ms between the microimages with magnifications 23.2 and 11.8 respectively), but the time delay between the microimage at the minima (i.e., at time delay 0) and the other microimages is in the regime where, at LIGO/Virgo frequencies, there could be observable effects. Even for the yellow source, one should expect a change in the magnification as a function of frequency at even lower frequencies, since the time delay is larger. In wave optics regime, the effect of microlenses extend farther away past the realm of the caustic region, increasing the probability of detecting a lensing event.

thumbnail Fig. 5.

Example of a source at z = 2 lensed by a microlens with 100 M embedded in a macromodel at z = 0.5 with magnifications μt = 10 and μr = 3. Left panel: the large image shows the magnification around the microlens in the image plane (with the critical curve) and the microimages. The small image on the bottom-right shows the magnification in the source plane with two sources in white and yellow. The surface brightness of the source is assumed to follow a Gaussian distribution (in white). Without the microlens, there would be a single lensed microimage with magnification 30. The microlens boosts the magnification by a factor ≈2 and breaks the macroimage into four microimages introducing time delays between them of up to 3.87 ms, i.e., in LIGO’s range. Right panel: similar to the left panel but for a microlens in the side with macromodel negative parity. We note how the high magnification region is now smaller but the maximum magnification can be higher. In contrast, areas of small relative magnification (and larger time delays) are more common.

On the side with negative parity (or saddle points of the time delay), the critical curves and the caustics split into two regions as shown in the right panel of Fig. 5. The critical curves remain circular but the region of low magnification is now between the two critical curves. The region of low magnification is significantly larger than the region of high magnification, which results in a higher probability of a GW being demagnified by the microlens than magnified by it (see Diego et al. 2018; Diego 2019, for a more specific quantification of this difference). The caustics break into two separate triangular regions of higher magnification (relative to the macromodel magnification), with a large area in between them of lower magnification (relative to the macromodel magnification). As mentioned above, the area containing the lower magnification region is significantly larger than the area of higher magnifications. This fact has direct consequences on the probability of observing lensed events of compact sources (in the geometric optics limit) which are less likely on regions where the macromodel parity is negative. A good example is the Icarus event (a highly magnified star at z = 1.49, Kelly et al. 2018) which has been consistently observed on the side with positive parity but remains demagnified most of the time on the side with negative parity. In wave optics, as we noted earlier, at very low frequencies the waves are unaffected by the microlenses. Hence, traditionally the probability of detecting or not detecting an event has been considered to be independent of the macroimage parity. However, at sufficiently high frequencies, we show below how the waves interfere and create constructive and destructive patterns at frequencies in the LIGO/Virgo window. This results in a modulation of the strain as a function of the frequency. If this modulation is not accounted for in the templates used in the matched filtering searches for GW, they could go unnoticed.

The properties of caustics in regions of the macromodel with positive and negative parity have been studied in detail in the literature (see for instance Kayser et al. 1986; Paczynski 1986; Wambsganss et al. 1990; Wyithe & Turner 2001; Kochanek 2004; Diego et al. 2018; Diego 2019). In the case of wave optics, this is not true (to the best of our knowledge) for microlensing of macroimages in regions with macromodel negative parity. The literature has focused so far only on microlensing of macroimages forming in macromodel regions with positive parity only, neglecting the impact that microlenses play on the macroimages forming in the regions with negative macromodel parity. In this work we study the two cases (parities) separately.

6.2. Microlensing of macroimages with positive parity

This case has been studied in detail in previous work (Ulmer & Goodman 1995; Nakamura 1998; Nakamura & Deguchi 1999; Takahashi & Nakamura 2003). Here we consider the particular case of a microlens with 100 M near a microimage that is being magnified by a macromodel by a factor 30. At this magnification, the signal to noise of the GW would be boosted by a factor 30 5.5 $ \sqrt{30}\approx 5.5 $. With this magnification, an event at z ≈ 1.9 with a chirp mass Mc ≈ 17 M would have been detected with the same significance as GW170729 (at z = 0.48 and with almost twice the chirp mass). At magnifications μ >  30 one expects ≈0.2 events per year between z = 1.9 and z = 2.1 (or ∼1 events per year in the redshift interval 2 <  z <  3) if one naively assumes a model for the rate evolution of GW events that traces the star formation rate history and it is normalized to 200 events per year and Gpc3 at z = 0 (consistent with current limits from LIGO) (see for instance Diego 2019, for an estimation of the probability of lensing at z ≈ 2 and for μ >  30).

To compute the magnification as a function of frequency, we consider two GWs at the positions indicated by the white and yellow dots in the left panel of Fig. 5. In Fig. 6 we show, in blue, the F(t) extracted from the time delay for the white source (the F(t) for the yellow source resembles that of the isolated microlens studied earlier with a single logarithmic peak at the time delay between the two yellow microimages). The inset on the top-right corner shows a zoom-in around the peak of F(t). The curve F(t) has three scales shown in the zoom-in inset plot, each one corresponding to a different time delay, 2.77 3.01 or 3.87 ms. The relative height of each feature is dictated by the magnification of each microimage, as originally shown by Ulmer & Goodman (1995). The first feature (at 2.77 ms) is a discontinuity corresponding to a microminima or micromaxima. The other two features are logarithmic divergences for each one of the two saddle points.

thumbnail Fig. 6.

F(t) for the white source shown in the left panel of Fig. 5. The zoom-in shows an enlarged version of the curve around the maxima. We note how the positions of the discontinuities and the logarithmic divergences correspond with the times shown in Fig. 5.

Using the curves F(t), one can easily compute the magnification as a function of frequency. The result is shown in Fig. 7. The red curve shows the magnification for the source inside the caustic region (white source in left panel of Fig. 5). The blue curve is for the source outside the caustic region (yellow source in left panel of Fig. 5). In both cases, the magnification is relative to the macromodel magnification, so magnification ≈1 in this plot is to be understood as total observed magnification ≈30. In the frequency range of LIGO (∼50 − 500 Hz), both curves exhibit features in the magnification that can be measured in future observations allowing for the unambiguous identification of lensed events (which would be otherwise difficult to recognize). At high frequencies, the red curve converges to the geometric optics limit prediction, that is to a mean value ≈2 times the magnification of the macromodel. However, at LIGO frequencies, the magnification can be up to six times larger than the magnification from the macromodel, boosting the detectability of the GW in a given frequency range. This is a consequence of the constructive interference that takes place at certain frequencies. In the case of the blue curve, an undulatory behavior is observed even at lower frequencies (consequence of the larger time delay of 8.7 ms). Since one counterimage is magnified by a factor 25.2 and the other by a factor ≈3 times smaller, a complete cancellation of the signal can not take place but the interference is large enough to be detected with the proper template. A classic search of GWs using standard templates may miss these events if this type of interference pattern is not accounted for. However, candidates to lensed events could be identified based on their unusually high chirp mass and/or low redshift (Dai et al. 2017; Broadhurst et al. 2018, 2019; Hannuksela et al. 2019). Also, multiple image analysis can be performed by following the methods proposed by Haris et al. (2018).

thumbnail Fig. 7.

Observed magnification of the GW as a function of GW frequency for the two sources shown in the left panel of Fig. 5. The red curve is for the white source while the blue curve is for the yellow source.

Finally, it is important to note that the frequencies shown in the x-axis of the previous figures, scale as the inverse of the mass of the microlens (this follows from the scaling of ΔT with the mass of the microlens). A mass 5 times smaller (i.e., 20 M) would still show significant fluctuations in the observed magnification within the frequency range covered by LIGO/Virgo. This result is in apparent disagreement with earlier work that concluded that only isolated microlenses above 100 M could produce observable effects. However, that earlier work ignored the effect of the macromodel that helps boost the signal from the microlens. One should expect that at even larger magnifications, increasingly small masses may produce observable effects, similar to what happens in the geometric optics limit (see Diego et al. 2018, for a detailed discussion of this effect).

6.3. Microlensing of macroimages with negative parity

In the absence of microlenses (or substructure, in general), macroimages with negative parity behave similarly to macroimages with positive parity in the geometric optics limit. However, when microlenses are present, the behavior can change substantially depending on the parity of the macroimage. When a macroimage intersects a microlens, the macroimage breaks into smaller microimages. The net magnification of the group of microimages may be comparable, larger or smaller than the macromodel magnification depending on where the GW is taking place, in relation to the microcaustics from the microlens. Contrary to the behavior of macroimages, microimages can look very different depending on whether the microlens is on the side with positive or negative macromodel parity. In the particular case of microlenses on the side with macromodel negative parity, two microcaustics form with a gap of low magnification between them. The region of high magnification contained within the microcaustics can be much smaller than the area of low magnification in the gap. This results in a larger probability for microimages from a compact source to be demagnified if the corresponding macroimage is in a saddle point (or has negative parity) of the macromodel. We consider again a microlens with mass 100 M embedded in a macromodel with magnification −30. This would correspond approximately to the conjugate position of the macroimage considered in the previous subsection. The critical curves, and caustics are shown in the right panel of Fig. 5. We note how the low magnification region between the two caustics is significantly larger than the large magnification region inside the two caustics. In the geometric optics limit, the larger probability of demagnification is compensated by a larger magnification inside the caustics region, so a moving source traveling across a microcaustic region would have similar integrated flux independently of whether the microlens is on the side with positive macromodel parity or the side with negative macromodel parity. The periods of maximum flux are shorter but more intense when the microlens is on the side with negative macromodel parity than when the same microlens is on the side with positive macromodel parity. On the other hand, the periods of low relative magnification (relative to the macromodel magnification) are more prolonged and at lower magnifications on the side with negative macromodel parity (see more examples for varying magnifications in Diego et al. 2018; Diego 2019).

As in the previous subsection, we consider two sources that are shown in the inset small panel of the right side of Fig. 5. The white source is inside the small caustic region and is highly magnified as shown in the source plane. The yellow source is in the more extended low magnification region and has a much smaller magnification. The configuration of the microimages, together with their corresponding magnifications and relative time delays, are also shown in Fig. 5. For the white source, the relative time delays are significantly smaller than in the analogous case discussed in the previous section (≈5 times smaller). On the contrary, for the yellow source, the time delay is significant (≈8 ms) and well within LIGO/Virgo frequency window. The curve F(t) for the white source is shown as a blue curve in Fig. 8 (for the yellow source is again a simple logarithmic pulse). The blue curve shows one discontinuity corresponding to the microimage that arrives first and three logarithmic pulses for each one of the other microimages. The red curve in the same plot is the F(t) curve for the macromodel-only case, that is, without the microlens. In this case, the curve resembles the divergent logarithmic pulse typical of shallow points instead of a constant (like in the previous subsection).

thumbnail Fig. 8.

(Blue curve) F(t) curve for the white source shown in the right panel of Fig. 5. The zoom-in shows an enlarged version of the curve around the maxima. The red curve is the corresponding F(t) when the mass of the microlens is set to zero.

The magnifications are shown in Fig. 9. The red curve is for the white source that is being magnified by the microlens and the blue curve is for the yellow source that is being demagnified by the microlens. The small scale fluctuations in these curves are artifacts in the numerical method. The red curve is almost featureless in the frequency range covered by LIGO/Virgo but it exhibits a continuously growing magnification up to ∼1000 Hz that could be possible to be detected with future GW observations. On the contrary, the more likely event of the yellow source shows remarkable features that could be identified in future observations. At low frequencies, the magnification tends to the macromodel magnification but it falls sharply at around 100 Hz to then raise again and oscillate around a relative magnification of ≈0.25 relative to the macromodel magnification. The fact that at low frequencies GWs are unaffected by microlenses could be used to identify GW in the sense that these waves could appear in matched filtering searches at lower frequencies but then disappear when including higher frequencies. Meanwhile, unmodeled searches may be able to identify these events even at higher frequencies (e.g., Abbott et al. 2016, 2017a). A dedicated search could be made after a highly magnified GW is detected since its corresponding counterimage (macroimage) should closely follow (or precede) the observed lensed GW. For highly magnified events, the time delay between macroimages should range between ∼1 h to days or months (Ng et al. 2018; Smith et al. 2018a; Broadhurst et al. 2018) which should be useful to narrow the search for counterimages. As discussed in the earlier subsection, the time frequency scales with the inverse of the microlens mass so a microlens with mass as low as 20 M would still be detectable through the interference signature.

thumbnail Fig. 9.

Observed magnification of the GW as a function of GW frequency for the two sources shown in the right panel of Fig. 5. The red curve is for the white source (magnified with respect to the macromodel magnification) while the blue curve is for the yellow source (demagnified with respect to the macromodel magnification). We note how the blue curve converges to the smaller magnification value predicted in the geometric optics limit but it oscillates multiple times within the frequency range covered by LIGO.

7. Pair of microlenses at large macromodel magnification

The examples studied above are of interest for situations where a massive microlens intersects the path of a GW. In this section we study an alternative scenario where two smaller microlenses overlap their caustics in the source plane. This situation is interesting for large macromodel magnifications. As discussed earlier, a distant GW can be lensed by factors of a few tens with a non-negligible probability. Overlapping of caustics is not only possible, but unavoidable at large macromodel magnifications. The overlapping effect becomes increasingly more important as one approaches one of the critical curves of the macromodel. As the radial or tangential magnification approaches its diverging value (at the critical curve), a given number density of microlenses in the image plane (with their associated microcritical curves) results in a larger number density of microcaustics in the source plane. At some value of the macromodel magnification, regularly spaced microcritical curves in the image plane start to produce overlapping caustics in the source plane. A GW that intersects one of these overlapping regions will have its counterimages spread over the wider region covered by the corresponding microcritical curves, with the consequent increase in the number of time delays. As discussed in Sect. 2, relatively small microlenses embedded in a macromodel with large magnification can mimic the effect of a much larger microlens (in terms of time delays), and hence produce effects at LIGO/Virgo frequencies.

The number of possible combinations of microlens mass, distance between microlenses, and macromodel magnification is too large to be studied in detail. Here we present a simple example. We consider the special case where microlenses are primordial black holes (or PBH) with masses of a few tens of M (although our example is valid also for regular black holes, like those being found by LIGO/Virgo). PBHs are a viable candidate to explain a fraction of the dark matter. Even though observations rule out the possibility of PBH explaining all the dark matter in a wide range of masses, there are some windows where fractions of the order of 10% of the dark matter could still be in the form of compact objects, such as PBHs. One of these windows is for PBH masses of a few tens of M (Carr et al. 2017). Interestingly, the latest results on gravitational waves from BBH mergers could suggest a higher than expected abundance of black holes with masses of a few tens of M (Abbott 2018).

As above, we consider the two possibilities; macroimages forming on the side with positive parity and macroimages forming on the side with negative parity.

7.1. Macroimages with positive parity

We place two point masses with 25 M and 30 M in a macromodel with magnification ≈150 (or 50 × 3). The two microlenses are separated by a distance of 320 μas. At this separation, the macromodel projects the critical curves into two overlapping caustics as shown in the small panel of the left Fig. 10. The magnification of the macromodel is larger than in the previous sections by a factor 5. This translates into a probability 25 times smaller of having these events but the accessible volume increases by a factor ∼5 (compared with the volume up to z = 2) compensating partially the reduction in lensing probability. At large magnifications, the probability of microcaustics overlapping increases as discussed in detail in Diego et al. (2018), Diego (2019). An event in the source plane that takes place in the caustic overlapping region will produce multiple images around both critical curves. Figure 10 shows an example (in the geometric optics limit) of multiple images produced by a Gaussian source (depicted as a white round source in the small panel in the bottom right) that is placed in the overlapping caustic region. The total magnification in the geometric optics limit is ≈200, that is ≈33% times higher than the magnification that would be observed without the microlens. The microimage with the largest magnification is the one that arrives first and it appears in between the two critical curves. Smaller microimages form around each one of the critical curves. The time delays between the largest microimage and the other ones is of the order of a few milliseconds, sufficient to produce effects in the frequency range of LIGO/Virgo. Two of the smaller microimages are micro-minima or micro-maxima and the remaining four microimages are all saddle points. The F(t) curve for this case is shown in Fig. 11 as a dark blue curve. The zoom-in shows the two discontinuities and the four logarithmic impulses for the two micro-minima or micro-maxima and the four saddle points. Two other curves are shown in this plot for two alternative locations of the source. These two sources are marked with a red and yellow dots in the bottom-right part of the left panel in Fig. 10. The light-blue F(t) curve corresponds to the yellow dot and the red F(t) curve corresponds to the red dot. We note how in the light-blue curve, a saddle point microimage forms at relatively large time delays (dt ≈ 25 ms). The microimages for these alternative locations are not shown in Fig. 10 for simplicity purposes.

thumbnail Fig. 10.

Like in Fig. 5 but for two microlenses with 25 M and 30 M. Left panel: case where the two microlenses are on a region of the macromodel with positive parity while the right panel is for when the same microlenses are in a region of the macromodel with similar magnification but negative parity. In both cases, the small figure in the bottom-right corner shows the source plane with the caustics and the location of the sources. Only the microimages produced by the white sources are shown in the bigger figures.

thumbnail Fig. 11.

F(t) curves for the three sources shown in the left panel of Fig. 10. The dark blue curve is for the white source, the light-blue curve is for the yellow source and the red curve is for the red source.

The corresponding magnification is shown in Fig. 12. The color coding is the same as in Fig. 11. For the white source in Fig. 10 (dark-blue curve), a significant fluctuation is observed at ≈200 Hz. Above this frequency, the magnification increases quickly up to factor ≈4 with respect to the macromodel magnification at ≈300 Hz to later decline again. At large frequencies, the magnification converges to the geometric optics limit, that is ≈1.5 times the macromodel value. The red curve shows a similar, but milder, variability at LIGO/Virgo frequencies. In the light blue curve, the larger time delay imprints fluctuations in the magnification at even lower frequencies but these fluctuations are smaller in magnitude. It is important to note that, in the last two examples, even though at high frequencies the magnification converges to the geometric optics limit (below the macromodel value), and at very low frequencies the magnification converges to the macromodel value, in the intermediate (∼100 Hz) frequency range (the one best probed by LIGO/Virgo) the magnification can exceed that of the macromodel value improving the detectability of these events.

thumbnail Fig. 12.

Magnification for the three sources shown in the left panel of Fig. 10 as a function of frequency. The color coding is the same as in Fig. 11. The rapid oscillations in the light-blue curve are real and due to the peak at large time delays (≈25 ms) shown in the light-blue curve of Fig. 11.

It is important to note that, although the geometric time delay (i.e., the separation between microimages) is significantly larger in the case shown in Fig. 10 than the corresponding case shown in the left panel of Fig. 5, the time delays are still comparable. This is because the gravitational time delay is smaller when the macromodel potential is shallower (i.e., at larger macromodel magnifications), but also the potential of the microlenses is smaller.

7.2. Macroimages with negative parity

We place the same two sources at the same separation as in the previous subsection but the macromodel magnification is changed to its opposite value, that is μmacro = −150. When the microlens is on the side with macromodel negative parity, we find again the usual gap of low magnification between caustics (see small figure in the right panel of Fig. 10). In the configuration of the example shown in the figure, the caustic regions overlap, so a source placed in that overlapping region produces multiple images around the critical curves of both microlenses as shown in the figure. If the caustics do not overlap, but instead one of the microcaustics falls inside the low magnification region of the other microlens, and a source is placed within that caustic region, images with large amplification factors would form only around one of the microlenses while the other microlens would form only microimages with relatively small magnification factors. Sources placed in the low magnification regions would form two microimages if the source is placed in only one of the two low magnification regions or four microimages if the source is placed in the overlapping low magnification region. In Fig. 10 we show two sources, one white and one red. The white one is placed in the overlapping region of two caustics while the red one is placed in the low magnification region of one of the microlenses. The white source produces microimages with relatively moderate time delays (≈1.5 ms) between the microimages with the largest magnification. Longer time delays are only observed at the microimages with the smallest magnification. The red source (for which we do not show the counterimages) produces two small microimages near one of the microlenses.

The observed magnification of the GW of these two sources are shown in Fig. 13. The blue curve is for the white source and the red curve is for the red source. In the blue curve, we observe that, at low frequencies, the GW is insensitive to the microlens doublet as expected. However, within the frequency range proved by LIGO, the magnification increases by almost an order of magnitude that should imprint a modulation in the observed strain of a factor ≈3 between the early and late periods of the GW signal. The red curve shows the case of the source in the low magnification region. Between 100 Hz and 200 Hz the GW is demagnified by as much as a factor 5. Between 100 Hz and 300 Hz, it is re-amplified by a factor almost 3 and above 300 Hz is demagnified again up to 400 Hz and so on. This very distinctive behavior could be used to identify these events. Ironically, the GW that is less magnified may be easier to detect, since at low frequencies it is still being magnified by the macromodel, but at higher frequencies the GW would fade and oscillate.

thumbnail Fig. 13.

Magnification for the two sources shown in the right panel of Fig. 10 as a function of frequency. The dark blue curve is for the white source and the red curve is for the yellow source.

8. Field with stellar masses

In the previous sections we studied simple, but pedagogical and useful models with one massive microlens (100 M) or a pair of intermediate mass microlenses (≈30 M) in macromodel potentials with magnifications of ≈30 and ≈150 respectively. These previous examples are useful to understand the effect from single sources, or pairs of sources such as PBHs, but may not represent the most likely scenario. Instead, in real observations, most of the microlenses will be of stellar origin. Their abundance can be estimated based on the observed surface brightness that can be modeled with SEDs and a given IMF. In this section we address the question of the type of signal that can be produced when the GW travels through a field populated with stellar microlenses, and near a region of high magnification.

For typical situations near critical curves, one finds that the surface mass density of microlenses contributing to the intracluster medium, or in the outskirts of galactic lenses, is in the range of a few to a few tens of solar masses per parsec2. When fitting the observed flux, depending on whether one assumes a bottom heavy IMF such as a Salpeter IMF or a shallower IMF in the low-mass end such as a Chabrier IMF, the difference in the estimated surface mass density of microlenses can be typically a factor ≈2 (Morishita et al. 2017).

When a GW is observed with large magnification (due to the a macromodel), two macroimages are usually produced by the macromodel (galaxy or cluster) near one of the critical curves of the galaxy or cluster. At short distances from the critical curve, the role of microlenses from the galaxy halo, or intracluster medium, becomes important when the background source is small. This regime has been studied in detail in earlier work in the context of lensing of distant luminous stars (Kelly et al. 2018; Diego et al. 2018; Venumadhav et al. 2017). For GWs there is no previous study (to the best of our knowledge) on the effect of a population of microlenses on a GW that is magnified by a large factor.

We simulate an area in the image plane 1.2 mas × 1.2 mas = 1.44 mas2 with a surface mass density of microlenses of ≈12 M per parsec2. This is a typical value found in real situations near critical curves of macromodels where the magnifications can be large (this is for instance one of the values used to interpret the Icarus event Kelly et al. 2018). In general terms, we follow the procedure described in Diego (2019). The full simulation box has a size of 1.44 mas2 = 37.3 pc2 (at zs = 2), but we compute the deflection field and potential only in the central rectangular region of 1.2 × 0.2 mas2) (or target region) with a resolution of 20 nanoarcsec per pixel. In the original 1.442 arcmin2 area, we distribute randomly 2558 microlenses drawn from the stellar and remnant mass distribution computed for a Chabrier IMF to 0.01 M and the Fryer et al. (2012) initial-final mass function (with z = 0.5). The oldest living star has an initial mass of 1.5 M, and we use the mass-dependent binary fraction from Duchêne & Kraus (2013). The total stellar mass in the simulated region is 430 M, which results in 11.7 M pc−2. The most massive microlens (star or remnant) in our simulation has a mass of 19.3 M, although it falls outside the target region. Within the target region, the most massive microlens has a mass of 11.3 M. Our target region is large enough to be considered representative of the underlying distribution of microlenses. The parameters of the macromodel are given by the two values of the magnification, μr and μt. These values determine the magnitude of the convergence, κ, and shear, γ. From κ, and γ we derive the deflection field and potential of the macromodel following the procedure described in Sect. 2.

8.1. Positive parity

As before, we consider the scenarios of positive and negative macromodel parities separately. For a macromodel with μr = 50 and μt = 3 the resulting magnification in the lens plane is shown in Fig. 14 (on the side of the lens with positive parity). The critical regions correspond to the white curves. The smaller picture on the bottom-right side is for the entire target region, while the enlarged picture is a zoom of the rectangular region highlighted in the small picture. The large microlens on the left side has 11.3 M. The caustics in the source plane are shown in Fig. 15. The large microcaustic near the center corresponds to the 11.3 M microlens.

thumbnail Fig. 14.

Zoom-in the region around a pair of microlenses with 11.3 M and 2.2 M in our simulated map. The entire simulated region is shown in the bottom right corner with the zoomed region marked with a rectangle. The arcs formed by a background source are shown in white. Small microimages are marked with a white circle. The magnifications and relative time delays are shown for each microimage.

thumbnail Fig. 15.

Caustic region on the side with positive parity. This region shows approximately half the simulated region. The largest microcaustic corresponds to the largest microlens of 11.3 M. The red dot marks the position of the background source for which the microimages are shown in Fig. 14.

For the models considered in this work, the number of microlenses (stars and remnants) above ≈10 M is scarce. The time delays between microimages are typically ∼0.1 ms producing little noticeable effects at LIGO/Virgo frequencies. A few exceptions, where two microcaustics overlap, may result in larger time delays but usually still below 1 ms because small microlenses still need to be physically close to each other, in order for their small microcaustics to overlap. The probability of overlapping caustics is largest around the caustics of the most massive microlenses (black holes with > 5 M) since these caustics cover a relatively wide area in the source plane. For instance, in Fig. 15, a source is placed inside the caustic of the largest microlens in our target region (with 11.3 M). The source is also simultaneously inside the microcaustics of other smaller microlenses. The resulting microimages are shown in Fig. 14 in white. Next to each microimage we indicate their individual magnifications and time delay relative to the microimage that arrives first. Since the time delays between microimages with high magnification can be several ms, we expect the signature of interference to manifest itself at LIGO/Virgo frequencies. Note, however, how the group of microimages on the right side has relative times delays smaller than 0.1 ms. If the large microlens on the left were not present, these microimages would not result in significant distortions to the magnification at LIGO/Virgo frequencies.

The corresponding F(t) curve, for the configuration shown in Fig. 14 is shown in Fig. 16. The small time delays between microimages produced by the smaller microlenses are responsible for the multiple peaks below 0.1 ms (below 1 microarcsec there is another small peak not shown in the figure). The three microimages around the large microlens of 11.3 M produce the discontinuity at around 2 ms, and two small, almost overlapping logarithmic peaks.

thumbnail Fig. 16.

F(t) for the red source shown in Fig. 15 (and with the corresponding microimages shown in Fig. 14). Below 1 μs there is another peak not shown in this plot. The vertical dashed line marks the time delay of 1.8 ms.

In order to show what would have been the effect, should the large 11.3 M microlens not be present, we consider also the F(t) up to 1.8 ms (marked with a vertical dashed line in the figure) and compute the amplification in both scenarios. Figure 17 shows the relative magnification when considering the full spectrum (tmax = 8 ms, red solid curve) and when considering only the spectrum up to 1.8 ms (blue curve). In general, the red curve traces the blue curve, but has the additional harmonic produced by the peak in F(t) at ≈2 ms. The overlap of caustics from the large microlens and the smaller ones results in a modulation of the magnification at LIGO frequencies, where at frequencies ≈300 Hz the magnification is a factor ≈2 times smaller than at frequencies < 100 Hz (red curve). If the large microlens was not present, the overlapping of the two smaller caustics is not be sufficient to produce significant effects at LIGO/Virgo frequencies (blue curve).

thumbnail Fig. 17.

F(w) for the two lensed sources shown in Fig. 15 (a and b). The red and dark blue curves are for source a. The dark blue curve is the corresponding amplification that it is obtained if only the peaks below 1.8 ms are considered. The light blue curve is for the source b in Fig. 15.

8.2. Negative parity

When the parity of the macromodel is negative, we have seen in previous sections that microcaustics contain a relatively large area of low magnification in between the regions of high magnification. Figure 18 shows the caustics in a fraction of the simulated source plane. The distribution of microlenses is the same as the one discussed in the previous subsection. The large microlens in the image is also the same 11.3 M microlens discussed above. We place sources in three positions marked with (a), (b) and (c). The magnifications as a function of GW frequency are shown in Fig. 19. Sources (b) and (c) show the smallest departure from unity in the relative magnification at LIGO frequencies. Source (a) shows a deviation from unity, only at the largest LIGO frequencies that could be observed. We note how source (a) is not placed in the largest microlens but on a more moderate (and common) one with mass ≈2 M. On the side with negative parity, low magnification is more likely than high magnification so it is more likely than a macroimage on the side with negative parity suffers a larger distortion than a macroimage on the side with positive parity. If microlenses with masses as low a 2 M can produce interference patterns at LIGO/Virgo frequencies, this may affect the detectability of counterimages with negative parity as templated searches without lensing considerations could miss these patterns.

thumbnail Fig. 18.

Caustic region on the side with negative parity. Four source positions are labled with a, b, c and d.

thumbnail Fig. 19.

F(w) for the lensed sources shown in Fig. 18. The color of the curves is the same as the color of the sources in Fig. 18.

9. Effect over the GW strain

The results in the previous section show the effect of microlensing over the magnification of GWs. A more direct visualization of the real effect can be appreciated when the magnification factor is applied over a simulated strain, h:

h h lensed = F ( w , β ) h , $$ \begin{aligned} h \rightarrow h^\mathrm{lensed} = F({ w}, \beta ) h, \end{aligned} $$(14)

which accounts for both, the effect of the magnification, μ, and the phase shift, ϕ, due to lensing. In order to do this, we assume a merging event of a BBH at z = 2 with m1 = m2 = 10 M amplified by some larger macromodel magnification, μ ≈ 150 (as in the previous section). The unperturbed strain from the last orbits of the merging event is shown in Fig. 20 as a black solid line. The units in the y-axis are arbitrary and incorporate already the large magnification factor from the macromodel (as well as the phase, both encoded in F(w, β)). The dotted and dashed lines show the distorted strain as a consequence of the interference effect and the change in magnification and phase as a function of frequency. The cases considered in this plot are the same shown in Figs. 15 and 17 above. In particular, dotted lines are for the sources a and b in the side with positive macromdoel parity while dashed lines are for the sources a, b, c, and d in the side with negative macromdoel parity. In general, for microlenses with stellar masses as those considered in the previous section the effect is small and it is concentrated in the last cycles of the merger. Unsurprisingly, the case imposing the largest effect is the orange dashed line which corresponds to orange source d in Fig. 16 (orange curve in Fig. 17). The microlens that causes this distortions is the most massive in our simulation (11.3 M). However, even sources placed in the caustic region of a smaller microlens, like source b in Fig. 15 (in the caustic region of a microlens with a mass of 2.2 M) still show significant departures in the amplitude of the last cycle.

thumbnail Fig. 20.

Simulated strain with no-lensing of the coalescence of a BBH with 10 and 12 M at z = 2 (solid black line). We note that in order to zoom in the highest frequencies, we plot the strain as a function of |t − t0| where the time, t0, corresponds to zero in the x-axis. The dashed lines show the distortion of the strain for the different microlensing scenarios (by stellar bodies) discussed in Figs. 15 and 17.

Usually, one would quantify the detectability of these lensed events by Bayesian hypothesis testing using templated searches as in Lai et al. (2018). However, as no generic waveform templates exist for these microlensed waveforms, quantifying the detectability of these events in this way is difficult.

We instead quantify the correction to the waveform introduced by lensing by comparing the waveform match m(hlensed, hunlensed) (the normalized inner product (e.g., Maggiore 2008)) between the lensed and unlensed versions, weighted with the Advanced LIGO power spectral density at design sensitivity. Corrections of a few ∼3%, which are roughly equivalent to corrections introduced by spin effects, could have hope of leaving discernible patterns in the LIGO/Virgo strains. We generate two representative examples of lensed waveforms for the lens setting shown in Figs. 17 (red curve) and 19 (orange curve), and compute the match between their unlensed counterparts. Interesting modulation, or “beating patterns”, are present in the waveforms (Fig. 21, right panel) in comparison to the unlensed waveform, that may be discernible in the future. We note that in the orange curve, the small scale fluctuations are artifacts due to the noise in the computation of the relative magnification. The reason why the strain amplitude is larger at lower frequency is due to the binary spending longer time at these frequencies. Alternatively, the y-axis in the right panel of Fig. 21 can be also interpreted as the power spectrum of the strain as a function of time. However, the correction introduced by lensing in the waveforms is at around % level (Fig. 21, left panel), which could be difficult to detect at current sensitivities within LIGO/Virgo due to parameter degeneracies, noise, and the Occam’s razor (which at similar performance, favours models with fewer parameters).

thumbnail Fig. 21.

Left panel: waveform match between the microlensed and lensed waveform as a function of the total mass of the binary Mtot. Right panel: strain amplitude as a function of frequency for the lensed and unlensed waveform with Mtot = 20 M. The red and orange curves utilize the lens configurations and magnification factors shown in Figs. 17 and 19, respectively, while the black line (right panel) shows the unlensed waveform. The waveform corrections are at percent level.

One difficulty in detecting these small modulations induced by microlensing is that they mainly introduce amplitude modulations in the waveforms that are hard to discern with matched filtering schemes, and only small phase modulations. This is in contrast to phase modulations which could be more suitable for the current search methods. Another difficulty is that the most interesting lensing features range fall just slightly off the target frequency band of the LIGO/Virgo detectors.

While the few microlensing examples we have shown introduced relatively small corrections to the waveform, certain microlensing effects could perhaps be visible at design sensitivities. For example, we have verified that time delays of order ∼3 ms from two micro-images could introduce waveform corrections at the 10% level, assuming relative magnifications of 1:2. As the next generation of gravitational wave detectors are being built, the improved sensitivities they offer could open the observational window for these events. Improvements especially above 500 Hz, where the representative lens configurations here have shown interesting modulations in the amplification factors, would improve our odds of detecting these events. These detections could then be used to investigate and constrain populations of microlenses (including an alleged population of PBHs for which constraints could be imposed on their abundance through this technique), similarly to the studies in Diego et al. (2018).

Although not discussed in this paper, it may be important to consider the effect that undetected microlensing can have in the derivation of parameters. This is particularly iportant for those constraints that depend more on the last cycles, or the ringdown phase of the strain (highest frequencies), such as the spin.

10. Discussion and conclusions

GWs that are magnified (by a macromodel) by large factors can also be affected by the microlenses inside the macromodel. If the macromodel magnification is large enough (i.e., when the saturation regime mentioned in Sect. 2 is reached), microlensing is not only possible, but unavoidable. These microlenses imprint an interference pattern in the lensed GW, leaving a characteristic signature that can be used to unequivocally classify the event as a strongly lensed event. Hence, most if not all, GWs that are magnified by extreme factors are expected to exhibit some distortion in their strains as a consequence of the modulation of the magnification and phase as a function of frequency.

Microlenses near a macromodel critical curve behave as microlenses with a larger effective Einstein radius, and consequently the geometric time delay increases accordingly. In addition, when two microlenses are close in the source plane, they can work together acting as a single more massive microlens, and produce a larger time delay between the microimages.

Time delays between two microimages of the GW of order 1 ms result in interference patterns of the GW that affect the strain at LIGO/Virgo frequencies. We have shown how microlenses with masses of order 100 M in regions of the lens plane where the macromodel magnification is of order a few tens imprint very distinctive patterns in the magnification at LIGO/Virgo frequencies. For macroimages of negative parity, the role of microlenses becomes more important. In this case, the likelihood of a source falling in a region of low magnification is significantly higher than it is for high magnification when macroimages have positive parity. Morever, the more likely low magnification regions in the source plane imprint larger time delays in the observer plane, making interference of macroimages with negative parity, not only more likely, but also more pronounced at LIGO/Virgo frequencies.

Another important consequence of large macromodel magnifications is that the probability of microcaustic overlapping grows with the macromodel magnification. Overlapping caustics increase the number of microimages, and consequently the number of time delays. When the number of microimages is larger than 2, complex patterns can emerge in the magnification factor as a function of frequency. Two relatively small microlenses can also conspire together to produce a larger time delay if microlenses are sufficiently close. We demonstrate the combined effect of macromodel magnification and multiple microlenses with microlenses having a few tens of M, but also with realistic distributions of stellar bodies and their remnants. In the later case, we find that microlenses with masses less than a few M are less likely to produce significant distortions in the magnification pattern at LIGO/Virgo frequencies, even if their microcaustics are overlapping. However, overlapping microlenses with masses of a few solar masses, and close to the critical curve of the macromodel can result in time delays of order one millisecond, or larger, hence producing significant distortions in the magnification at LIGO/Virgo frequencies. For macroimages with negative parity, even a modest mass of ≈2 M can produce deviations at the 20% level in the highest frequency range probed by LIGO/Virgo (≈500 Hz) which could have an impact in the detectability of the signal, or at the parameter estimation level. Macroimages with negative parity are more likely to produce pronounced effects within LIGO/Virgo than macroimages with positive parity. However, the larger probability of de-magnification (relative to the magnification of the macromodel), specially at frequencies above 100 Hz, may represent a greater challenge to identify them in the noisy data. Consequently, strongly lensed GWs with negative parity are more likely to be missed than their counterimages with positive parity.

As already pointed out by earlier work, in the regime where wave optics is important, the effect of microlenses over a GW extend farther away from the caustic region. This increases the probability (or effective optical depth) of detecting a microlensing event through its distortion in the magnification. We have shown how interference can take place even at low magnifications (which would pass unrecognized as a lensed event). An appropriate optimal filter could perhaps unveil GW that present such interferences in certain lensing configurations. Detecting the interference signature in present data will be challenging given the relatively high noise level, parameter degeneracies, and Occam’s razor argument.

We have quantified this effect by estimating the percentage of correction introduced to the waveform by these lensing interference patterns. Since most of the effect is produced at frequencies above 100 Hz (for normal stellar mass microlenses), the most intriguing range falls just slightly off the optimal frequency range of the LIGO/Virgo detectors. However, when future detectors such as the Einstein Telescope and Cosmic Explorer (see Punturo et al. 2010; Abbott et al. 2017b; Dwyer et al. 2015; Abernathy et al. 2011) become operational with much better sensitivities, detecting these events will become significantly more likely.

An interesting application of lensing of GWs is using the time delay in the context of multimessenger astrophysics. As suggested by Baker & Trodden (2017), these time delays induced by gravitational lensing of gravitational waves in unison with their electromagnetic counterpart could be used to constrain the cosmological models (for instance by setting bounds on the total neutrino mass). The time delay induced by microlenses can be inferred from the modulation of the observed strain. This time delay will normally be in the range of a millisecond to a few milliseconds. Although Baker & Trodden (2017) considers neutrinos and GWs, EM counterparts can be used as well to derive cosmological information (Wei & Wu 2017; Liao et al. 2017; Yang et al. 2018; Li et al. 2018b). Fast Radio Bursts (FRBs) would make ideal electromagnetic (EM) counterparts since their duration is also comparable to the time delay (and time delays of order a ms can be measured from them). However, the origin of FRBs is still unclear and probably not linked to BBH mergers. The ideal EM pulse must be associated with the merger event (in order for the pulse to follow the exact same path as the GW) leaving the coalescence of binary neutron stars as the optimal candidates. Future GW detectors, with sufficient sensitivity to observe lensed binary neutron star mergers, such as the Einstein telescope, may be able to study them. Also, in BNS or BNBH mergers, the chirp mass is smaller, and consequently the frequency larger. For these type or mergers, microlensing events from stellar masses will be more relevant due to the higher frequency of the GW. Observing a BNS through lensing requires large magnification factors since the chirp mass (and consequently the signal-to-nose ratio) for these type of events is smaller, and the optical depth for events at redshift below ≈0.3 is also very small. In order to compensate for the increased luminosity distance (required to increase the optical depth of lensing and see a lensed BNS), the magnifcation factors need to be large (hundreds or thousands). If BNS mergers are more common than BBH mergers, strongly magnified BNS with magnifications factors of several hundreds could be soon observed, and microlensing events affecting these GWs could be studied in more detail.

Although not discussed in this paper (and with little prospects of being a viable type of observations in the near future), our results are relevant also for radio astronomy in the range of the kHz and operating from space. In this regime, radio pulses like those emitted by pulsars or FRB (assuming they still have sufficient power at these very low frequencies) could be lensed by microlenses of stellar, or substellar masses, and result in interference patters similar to those presented in this work.


1

The approximation would be valid, however, for microlenses in our own Galaxy.

Acknowledgments

J.M.D. acknowledges the support of projects AYA2015-64508-P (MINECO/FEDER, UE), funded by the Ministerio de Economia y Competitividad. J.M.D. acknowledges the hospitality of the Physics Department at the University of Pennsylvania for hosting him during the preparation of this work. The authors thank Mark Trodden for useful comments. O.A.H. is supported by the Hong Kong Ph.D. Fellowship Scheme (HKPFS) issued by the Research Grants Council (RGC) of Hong Kong. The work of O.A.H., K.K., and T.G.F.L. was partially supported by grants from the Research Grants Council of the Hong Kong (Project No. CUHK14310816, CUHK24304317 and/or CUHK 14306218) and the Direct Grant for Research from the Research Committee of the Chinese University of Hong Kong.

References

  1. Abbott, B. P., Abbott, R., Abbott, T. D., et al. 2016, Phys. Rev. D, 93, 122004 [NASA ADS] [CrossRef] [Google Scholar]
  2. Abbott, B. P., Abbott, R., Abbott, T. D., et al. 2017a, Phys. Rev. D, 95, 042003 [NASA ADS] [CrossRef] [Google Scholar]
  3. Abbott, B. P., Abbott, R., Abbott, T., et al. 2017b, Class. Quant. Grav., 34, 044001 [NASA ADS] [CrossRef] [Google Scholar]
  4. Abernathy, M., Acernese, F., Ajith, P., et al. 2011, Einstein gravitational wave Telescope conceptual design study (European Gravitational Observatory), Document Number: ET-0106A-10 [Google Scholar]
  5. Akutsu, T., Ando, M., Araki, S., et al. 2018, Prog. Theor. Exp. Phys., 2018, 013F01 [CrossRef] [Google Scholar]
  6. Aso, Y., Michimura, Y., Somiya, K., et al. 2013, Phys. Rev. D, 88, 043007 [NASA ADS] [CrossRef] [Google Scholar]
  7. Baker, T., & Trodden, M. 2017, Phys. Rev. D, 95, 063512 [NASA ADS] [CrossRef] [Google Scholar]
  8. Broadhurst, T., Diego, J. M., & Smoot, III., G. 2018, ArXiv e-prints [arXiv:1802.05273] [Google Scholar]
  9. Broadhurst, T., Diego, J. M., & Smoot, III., G. 2019, ArXiv e-prints [arXiv:1901.03190] [Google Scholar]
  10. Cao, Z., Li, L.-F., & Wang, Y. 2014, Phys. Rev. D, 90, 062003 [NASA ADS] [CrossRef] [Google Scholar]
  11. Carr, B., Raidal, M., Tenkanen, T., Vaskonen, V., & Veermäe, H. 2017, Phys. Rev. D, 96, 023514 [NASA ADS] [CrossRef] [Google Scholar]
  12. Chang, K., & Refsdal, S. 1979, Nature, 282, 561 [Google Scholar]
  13. Chang, K., & Refsdal, S. 1984, A&A, 132, 168 [NASA ADS] [Google Scholar]
  14. Chen, W., Kelly, P. L., Diego, J. M., et al. 2019, ArXiv e-prints [arXiv:1902.05510] [Google Scholar]
  15. Chen, Z.-C., & Huang, Q.-G. 2018, ApJ, 864, 61 [NASA ADS] [CrossRef] [Google Scholar]
  16. Christian, P., Vitale, S., & Loeb, A. 2018, Phys. Rev. D, 98, 103022 [NASA ADS] [CrossRef] [Google Scholar]
  17. Dai, L., Venumadhav, T., & Sigurdson, K. 2017, Phys. Rev. D, 95, 044011 [NASA ADS] [CrossRef] [Google Scholar]
  18. Dai, L., Li, S.-S., Zackay, B., Mao, S., & Lu, Y. 2018, Phys. Rev. D, 98, 104029 [NASA ADS] [CrossRef] [Google Scholar]
  19. Deguchi, S., & Watson, W. D. 1986, ApJ, 307, 30 [NASA ADS] [CrossRef] [Google Scholar]
  20. Diego, J. M. 2019, A&A, 625, A84 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
  21. Diego, J. M., Kaiser, N., Broadhurst, T., et al. 2018, ApJ, 857, 25 [NASA ADS] [CrossRef] [Google Scholar]
  22. Duchêne, G., & Kraus, A. 2013, ARA&A, 51, 269 [Google Scholar]
  23. Dwyer, S., Sigg, D., Ballmer, S. W., et al. 2015, Phys. Rev. D, 91, 082001 [NASA ADS] [CrossRef] [Google Scholar]
  24. Fryer, C. L., Belczynski, K., Wiktorowicz, G., et al. 2012, ApJ, 749, 91 [NASA ADS] [CrossRef] [Google Scholar]
  25. Fukugita, M., Futamase, T., Kasai, M., & Turner, E. L. 1992, ApJ, 393, 3 [NASA ADS] [CrossRef] [Google Scholar]
  26. Halder, A., Banerjee, S., & Majumdar, D. 2019, ArXiv e-prints [arXiv:1902.06903] [Google Scholar]
  27. Hannuksela, O., Haris, K., Ng, K., et al. 2019, ApJ, 874, L2 [NASA ADS] [CrossRef] [Google Scholar]
  28. Haris, K., Mehta, A. K., Kumar, S., Venumadhav, T., & Ajith, P. 2018, ArXiv e-prints [arXiv:1807.07062] [Google Scholar]
  29. Hilbert, S., White, S. D. M., Hartlap, J., & Schneider, P. 2008, MNRAS, 386, 1845 [NASA ADS] [CrossRef] [Google Scholar]
  30. Iyer, B., Souradeep, T., Unnikrishnan, C. S., et al. 2011, LIGO India, Tech. Rep. LIGO-M1100296, https://dcc.ligo.org/LIGO-M1100296/public [Google Scholar]
  31. Jung, S., & Shin, C. S. 2019, Phys. Rev. Lett., 122, 041103 [NASA ADS] [CrossRef] [Google Scholar]
  32. Kayser, R., Refsdal, S., & Stabell, R. 1986, A&A, 166, 36 [NASA ADS] [Google Scholar]
  33. Kelly, P. L., Diego, J. M., Rodney, S., et al. 2018, Nat. Astron., 2, 334 [NASA ADS] [CrossRef] [Google Scholar]
  34. Kochanek, C. S. 1996, ApJ, 466, 638 [NASA ADS] [CrossRef] [Google Scholar]
  35. Kochanek, C. S. 2004, ApJ, 605, 58 [Google Scholar]
  36. Lai, K.-H., Hannuksela, O. A., Herrera-Martín, A., et al. 2018, Phys. Rev. D, 98, 083005 [NASA ADS] [CrossRef] [Google Scholar]
  37. Li, S.-S., Mao, S., Zhao, Y., & Lu, Y. 2018a, MNRAS, 476, 2220 [NASA ADS] [CrossRef] [Google Scholar]
  38. Li, X., Tang, L., Lin, H.-N., & Wang, L.-L. 2018b, Chin. Phys. C, 42, 095104 [NASA ADS] [CrossRef] [Google Scholar]
  39. Liao, K., Fan, X.-L., Ding, X., Biesiada, M., & Zhu, Z.-H. 2017, Nat. Commun., 8, 1148 [NASA ADS] [CrossRef] [Google Scholar]
  40. LIGO Scientific Collaboration, Virgo Collaboration, Abbott, B. P., et al. 2018, ArXiv e-prints [arXiv:1811.12907] [Google Scholar]
  41. Liu, L., Guo, Z.-K., & Cai, R.-G. 2018, Phys. Rev. D, 99, 063523 [NASA ADS] [CrossRef] [Google Scholar]
  42. Liu, L., Guo, Z. K., & Cai, R. G. 2019, ArXiv e-prints [arXiv:1901.07672] [Google Scholar]
  43. Madau, P., & Dickinson, M. 2014, ARA&A, 52, 415 [NASA ADS] [CrossRef] [Google Scholar]
  44. Maggiore, M. 2008, Gravitational Waves: Volume 1: Theory and Experiments (Oxford University Press), 1 [Google Scholar]
  45. Morishita, T., Abramson, L. E., Treu, T., et al. 2017, ApJ, 846, 139 [NASA ADS] [CrossRef] [Google Scholar]
  46. Nakamura, T. T. 1998, Phys. Rev. Lett., 80, 1138 [NASA ADS] [CrossRef] [Google Scholar]
  47. Nakamura, T. T., & Deguchi, S. 1999, Prog. Theor. Phys. Suppl., 133, 137 [NASA ADS] [CrossRef] [Google Scholar]
  48. Ng, K. K. Y., Wong, K. W. K., Broadhurst, T., & Li, T. G. F. 2018, Phys. Rev. D, 97, 023012 [NASA ADS] [CrossRef] [Google Scholar]
  49. Oguri, M. 2018, MNRAS, 480, 3842 [NASA ADS] [CrossRef] [Google Scholar]
  50. Oguri, M., Diego, J. M., Kaiser, N., Kelly, P. L., & Broadhurst, T. 2018, Phys. Rev. D, 97, 023518 [NASA ADS] [CrossRef] [Google Scholar]
  51. Paczynski, B. 1986, ApJ, 301, 503 [NASA ADS] [CrossRef] [Google Scholar]
  52. Punturo, M., Abernathy, M., Acernese, F., et al. 2010, Class. Quant. Grav., 27, 194002 [Google Scholar]
  53. Raidal, M., Spethmann, C., Vaskonen, V., & Veermäe, H. 2019, J. Cosmol. Astropart. Phys., 2, 018 [NASA ADS] [CrossRef] [Google Scholar]
  54. Schneider, P., Ehlers, J., & Falco, E. E. 1992, Gravitational Lenses (Berlin, Heidelberg, New York: Springer-Verlag), 112 [Google Scholar]
  55. Sereno, M., Sesana, A., Bleuler, A., et al. 2010, Phys. Rev. Lett., 105, 251101 [NASA ADS] [CrossRef] [Google Scholar]
  56. Smith, G. P., Jauzac, M., Veitch, J., et al. 2018a, MNRAS, 475, 3823 [NASA ADS] [CrossRef] [Google Scholar]
  57. Smith, G. P., Berry, C., Bianconi, M., et al. 2018b, IAU Symp., 338, 98 [NASA ADS] [Google Scholar]
  58. Smith, G. P., Bianconi, M., Jauzac, M., et al. 2018c, MNRAS, 485, 5180 [Google Scholar]
  59. Somiya, K. 2012, Class. Quant. Grav., 29, 124007 [Google Scholar]
  60. Stratton, T., & Dolan, S. R. 2019, ArXiv e-prints [arXiv:1903.00025] [Google Scholar]
  61. Takahashi, R., & Nakamura, T. 2003, ApJ, 595, 1039 [NASA ADS] [CrossRef] [Google Scholar]
  62. Takahashi, R., Oguri, M., Sato, M., & Hamana, T. 2011, ApJ, 742, 15 [NASA ADS] [CrossRef] [Google Scholar]
  63. Turner, E. L., Ostriker, J. P., & Gott, III., J. R. 1984, ApJ, 284, 1 [NASA ADS] [CrossRef] [Google Scholar]
  64. Ulmer, A., & Goodman, J. 1995, ApJ, 442, 67 [NASA ADS] [CrossRef] [Google Scholar]
  65. Venumadhav, T., Dai, L., & Miralda-Escudé, J. 2017, ApJ, 850, 49 [NASA ADS] [CrossRef] [Google Scholar]
  66. Wambsganss, J., Paczynski, B., & Schneider, P. 1990, ApJ, 358, L33 [NASA ADS] [CrossRef] [Google Scholar]
  67. Wang, Y., Stebbins, A., & Turner, E. L. 1996, Phys. Rev. Lett., 77, 2875 [NASA ADS] [CrossRef] [Google Scholar]
  68. Wei, J.-J., & Wu, X.-F. 2017, MNRAS, 472, 2906 [NASA ADS] [CrossRef] [Google Scholar]
  69. Wyithe, J. S. B., & Turner, E. L. 2001, MNRAS, 320, 21 [NASA ADS] [CrossRef] [Google Scholar]
  70. Yang, T., Hu, B., Cai, R. G., & Wang, B. 2018, ArXiv e-prints [arXiv:1810.00164] [Google Scholar]

All Figures

thumbnail Fig. 1.

Time delay in one dimension with two and three microlenses. The microlenses are at positions A, B, and C. The dashed lines show the time delay when only one of the three microlenses is considered. The solid lines corresponds to the time delay when two or three microlenses are considered. Microimages form around the positions where the derivative of the time delay equals zero. The magnification of each microimage is inversely proportional to the curvature (i.e., second derivatives) of the time delay around these positions.

In the text
thumbnail Fig. 2.

Microlensing by a 100 M star at two different macromodel magnifications of 15 (μt = 5 and μr = 3, left) and 60 (μt = 20 and μr = 3, right). The field of view is the same in both cases. In each case, the larger panel shows the magnification in the lens plane (critical curve) while the small panel in the bottom-right corner shows the corresponding magnification in the source plane (caustic). The small white dot inside the caustic marks the position of the source. The numbers in the larger panels indicate the magnification of each microimage and the corresponding time delays (in milliseconds) relative to the image that arrives first (marked with 0 ms). The separation between the source and the projected position of the microlens is the same in both cases. We note how at larger macromodel magnifications, both the time delays and the area enclosed by the caustic (i.e., the probability of microlensing) are larger.

In the text
thumbnail Fig. 3.

Function F(t) for an isolated point mass with 100 M and at a distance from the singular caustic Y = βE = 0.05 (blue solid line) and Y = 0.1 (red solid line). Both curves are normalized to 1 at large time delays.

In the text
thumbnail Fig. 4.

Predicted magnification for an isolated point mass with 100 M and at a distance from the singular caustic Y = βE = 0.05 (blue lines) and Y = 0.1 (red lines). The dashed lines show the analytical (exact) prediction. The dotted lines show the result obtained with the numerical algorithm.

In the text
thumbnail Fig. 5.

Example of a source at z = 2 lensed by a microlens with 100 M embedded in a macromodel at z = 0.5 with magnifications μt = 10 and μr = 3. Left panel: the large image shows the magnification around the microlens in the image plane (with the critical curve) and the microimages. The small image on the bottom-right shows the magnification in the source plane with two sources in white and yellow. The surface brightness of the source is assumed to follow a Gaussian distribution (in white). Without the microlens, there would be a single lensed microimage with magnification 30. The microlens boosts the magnification by a factor ≈2 and breaks the macroimage into four microimages introducing time delays between them of up to 3.87 ms, i.e., in LIGO’s range. Right panel: similar to the left panel but for a microlens in the side with macromodel negative parity. We note how the high magnification region is now smaller but the maximum magnification can be higher. In contrast, areas of small relative magnification (and larger time delays) are more common.

In the text
thumbnail Fig. 6.

F(t) for the white source shown in the left panel of Fig. 5. The zoom-in shows an enlarged version of the curve around the maxima. We note how the positions of the discontinuities and the logarithmic divergences correspond with the times shown in Fig. 5.

In the text
thumbnail Fig. 7.

Observed magnification of the GW as a function of GW frequency for the two sources shown in the left panel of Fig. 5. The red curve is for the white source while the blue curve is for the yellow source.

In the text
thumbnail Fig. 8.

(Blue curve) F(t) curve for the white source shown in the right panel of Fig. 5. The zoom-in shows an enlarged version of the curve around the maxima. The red curve is the corresponding F(t) when the mass of the microlens is set to zero.

In the text
thumbnail Fig. 9.

Observed magnification of the GW as a function of GW frequency for the two sources shown in the right panel of Fig. 5. The red curve is for the white source (magnified with respect to the macromodel magnification) while the blue curve is for the yellow source (demagnified with respect to the macromodel magnification). We note how the blue curve converges to the smaller magnification value predicted in the geometric optics limit but it oscillates multiple times within the frequency range covered by LIGO.

In the text
thumbnail Fig. 10.

Like in Fig. 5 but for two microlenses with 25 M and 30 M. Left panel: case where the two microlenses are on a region of the macromodel with positive parity while the right panel is for when the same microlenses are in a region of the macromodel with similar magnification but negative parity. In both cases, the small figure in the bottom-right corner shows the source plane with the caustics and the location of the sources. Only the microimages produced by the white sources are shown in the bigger figures.

In the text
thumbnail Fig. 11.

F(t) curves for the three sources shown in the left panel of Fig. 10. The dark blue curve is for the white source, the light-blue curve is for the yellow source and the red curve is for the red source.

In the text
thumbnail Fig. 12.

Magnification for the three sources shown in the left panel of Fig. 10 as a function of frequency. The color coding is the same as in Fig. 11. The rapid oscillations in the light-blue curve are real and due to the peak at large time delays (≈25 ms) shown in the light-blue curve of Fig. 11.

In the text
thumbnail Fig. 13.

Magnification for the two sources shown in the right panel of Fig. 10 as a function of frequency. The dark blue curve is for the white source and the red curve is for the yellow source.

In the text
thumbnail Fig. 14.

Zoom-in the region around a pair of microlenses with 11.3 M and 2.2 M in our simulated map. The entire simulated region is shown in the bottom right corner with the zoomed region marked with a rectangle. The arcs formed by a background source are shown in white. Small microimages are marked with a white circle. The magnifications and relative time delays are shown for each microimage.

In the text
thumbnail Fig. 15.

Caustic region on the side with positive parity. This region shows approximately half the simulated region. The largest microcaustic corresponds to the largest microlens of 11.3 M. The red dot marks the position of the background source for which the microimages are shown in Fig. 14.

In the text
thumbnail Fig. 16.

F(t) for the red source shown in Fig. 15 (and with the corresponding microimages shown in Fig. 14). Below 1 μs there is another peak not shown in this plot. The vertical dashed line marks the time delay of 1.8 ms.

In the text
thumbnail Fig. 17.

F(w) for the two lensed sources shown in Fig. 15 (a and b). The red and dark blue curves are for source a. The dark blue curve is the corresponding amplification that it is obtained if only the peaks below 1.8 ms are considered. The light blue curve is for the source b in Fig. 15.

In the text
thumbnail Fig. 18.

Caustic region on the side with negative parity. Four source positions are labled with a, b, c and d.

In the text
thumbnail Fig. 19.

F(w) for the lensed sources shown in Fig. 18. The color of the curves is the same as the color of the sources in Fig. 18.

In the text
thumbnail Fig. 20.

Simulated strain with no-lensing of the coalescence of a BBH with 10 and 12 M at z = 2 (solid black line). We note that in order to zoom in the highest frequencies, we plot the strain as a function of |t − t0| where the time, t0, corresponds to zero in the x-axis. The dashed lines show the distortion of the strain for the different microlensing scenarios (by stellar bodies) discussed in Figs. 15 and 17.

In the text
thumbnail Fig. 21.

Left panel: waveform match between the microlensed and lensed waveform as a function of the total mass of the binary Mtot. Right panel: strain amplitude as a function of frequency for the lensed and unlensed waveform with Mtot = 20 M. The red and orange curves utilize the lens configurations and magnification factors shown in Figs. 17 and 19, respectively, while the black line (right panel) shows the unlensed waveform. The waveform corrections are at percent level.

In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.