Issue |
A&A
Volume 666, October 2022
|
|
---|---|---|
Article Number | A127 | |
Number of page(s) | 20 | |
Section | Extragalactic astronomy | |
DOI | https://doi.org/10.1051/0004-6361/202244162 | |
Published online | 14 October 2022 |
Black hole mass estimation using X-ray variability measurements in Seyfert galaxies
1
Institute for Astronomy Astrophysics Space Applications and Remote Sensing (IAASARS), National Observatory of Athens, I. Metaxa & V. Pavlou, Penteli 15236, Greece
e-mail: aakylas@noa.gr
2
Department of Physics and Institute of Theoretical and Computational Physics, University of Crete, 71003 Heraklion, Greece
3
Institute of Astrophysics – FORTH, N. Plastira 100, 70013 Vassilika Vouton, Greece
Received:
1
June
2022
Accepted:
4
August
2022
Aims. Our objective is to critically assess the X-ray flux variability as a tool for measuring the black hole (BH) mass in active galactic nuclei (AGN). We aim to establish a prescription for estimating BH masses based on measurements of the normalised excess variance from X-ray data. We discuss the minimum requirements in terms of the light-curve duration and X-ray signal-to-noise ratio (S/N) to enable a reliable determination that is comparable to what can be derived from the continuum and emission line reverberation studies.
Methods. We used the light curves of local Seyfert from the Nuclear Spectroscopic Telescope Array hard X-ray mission (NuSTAR), to compute the normalised excess variance (σNXV2) in the 3–10 and 10–20 keV bands, thus extending the analysis to an energy band higher than 10 keV. The excess variance measurements were then combined with independent BH mass estimates from the literature to establish the MBH vs. σNXV2 relation for different samples and weigh its accuracy in terms of the light-curve duration and X-ray S/N.
Results. We find that it is possible to accurately measure the BH mass in AGN using excess variance measurements in the 3–10 and the 10–20 keV bands, however, strong quality requirements should be applied. The minimum necessary S/N and duration of the light curves used to compute the excess variance ought to be ∼3 and ∼80 − 100 ks, respectively. We provide a linear relationship between the normalised excess variance and the black hole mass that can be used to estimate the latter, with an average uncertainty of the order of 0.4 − 0.25 dex (depending on the adopted light-curve segment duration). In general, BH mass estimates from 3–10 keV and 10–20 keV band light curves are expected to be similar. The 10–20 keV band is preferred for sources that are heavily absorbed and the 3–10 keV band is preferred for sources that may be dominated by the X-ray reflection component at energies above 10 keV.
Key words: black hole physics / X-rays: galaxies / galaxies: active / galaxies: Seyfert / accretion, accretion disks / quasars: supermassive black holes
© A. Akylas et al. 2022
Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This article is published in open access under the Subscribe-to-Open model. Subscribe to A&A to support open access publication.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.