Issue |
A&A
Volume 636, April 2020
|
|
---|---|---|
Article Number | A21 | |
Number of page(s) | 11 | |
Section | Astronomical instrumentation | |
DOI | https://doi.org/10.1051/0004-6361/201937121 | |
Published online | 08 April 2020 |
Angular differential kernel phases
1
Université Côte d’Azur, Observatoire de la Côte d’Azur, CNRS, Laboratoire Lagrange, Lagrange, France
e-mail: romain.laugier@oca.eu
2
Research School of Astronomy & Astrophysics, Australian National University, Canberra, ACT 2611, Australia
3
Subaru Telescope, National Astronomical Observatory of Japan, National Institutes of Natural Sciences (NINS), 650 North Aohoku Place, Hilo, HI 96720, USA
4
Steward Observatory, University of Arizona, Tucson, AZ 85721, USA
5
College of Optical Sciences, University of Arizona, Tucson, AZ 85721, USA
6
Astrobiology Center of NINS, 2-21-1, Osawa, Mitaka, Tokyo 181-8588, Japan
7
European Southern Observatory, Karl-Schwarzschild-Str 2, 85748 Garching, Germany
Received:
15
November
2019
Accepted:
24
February
2020
Context. To reach its optimal performance, Fizeau interferometry requires that we work to resolve instrumental biases through calibration. One common technique used in high contrast imaging is angular differential imaging, which calibrates the point spread function and flux leakage using a rotation in the focal plane.
Aims. Our aim is to experimentally demonstrate and validate the efficacy of an angular differential kernel-phase approach, a new method for self-calibrating interferometric observables that operates similarly to angular differential imaging, while retaining their statistical properties.
Methods. We used linear algebra to construct new observables that evolve outside of the subspace spanned by static biases. On-sky observations of a binary star with the SCExAO instrument at the Subaru telescope were used to demonstrate the practicality of this technique. We used a classical approach on the same data to compare the effectiveness of this method.
Results. The proposed method shows smaller and more Gaussian residuals compared to classical calibration methods, while retaining compatibility with the statistical tools available. We also provide a measurement of the stability of the SCExAO instrument that is relevant to the application of the technique.
Conclusions. Angular differential kernel phases provide a reliable method for calibrating biased observables. Although the sensitivity at small separations is reduced for small field rotations, the calibration is effectively improved and the number of subjective choices is reduced.
Key words: instrumentation: high angular resolution / techniques: image processing / techniques: interferometric / methods: numerical
© Romain Laugier et al. 2020
Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.