Open Access

Table 3.

Best-fit parameters of the cie models applied on the continuum model for the four analysed datasets.

Model Parameter Archive-only All-times 0921360101 0921360201
cie0 (Thermal wind) vLOS(c) =0(a) =0(a) =0(a) =0(a)
σv (km/s) 2000 1000 + 3000 Mathematical equation: $ 2000^{+3000}_{-1000} $ 2000 500 + 800 Mathematical equation: $ 2000^{+800}_{-500} $ 4000 2000 + 4000 Mathematical equation: $ 4000^{+4000}_{-2000} $ 5000 ± 5000
kT (keV) 0.12 ± 0.02 0.16 ± 0.02 0.92 ± 0.07 2 . 9 1.2 + 4.1 Mathematical equation: $ 2.9^{+4.1}_{-1.2} $
L X cie ( 10 38 erg / s ) Mathematical equation: $ \mathrm{L}_{\mathrm{X}}^{\mathrm{cie}}\, (10^{38} \mathrm{erg/s}) $ 1.0 ± 0.6 0.84 ± 0.08 2.6 ± 0.8 5 ± 3
ΔC-stat 15 18 17 6

cieB (Blue wing) vLOS(c) −0.2960 ± 0.0006 0 . 2966 0.0002 + 0.0010 Mathematical equation: $ -0.2966^{+0.0010}_{-0.0002} $ 0 . 181 0.107 + 0.002 Mathematical equation: $ -0.181^{+0.002}_{-0.107} $ −0.1987 ± 0.0008
σv (km/s) < 500 < 200 1000 500 + 800 Mathematical equation: $ 1000^{+800}_{-500} $ < 500
kTcie (keV) 0.48 ± 0.08 0 . 40 0.05 + 0.10 Mathematical equation: $ 0.40^{+0.10}_{-0.05} $ 0.50 ± 0.08 0.50 ± 0.08
L X cie ( 10 38 erg / s ) Mathematical equation: $ \mathrm{L}_{\mathrm{X}}^{\mathrm{cie}}\, (10^{38} \mathrm{erg/s}) $ 0.5 ± 0.1 0.38 ± 0.04 0.7 ± 0.2 0.9 ± 0.3
ΔC-stat 26 25 14 15

cieR (Red wing) vLOS(c) 0.348 ± 0.001 0 . 3473 0.0007 + 0.0005 Mathematical equation: $ 0.3473^{+0.0005}_{-0.0007} $ 0 . 182 0.004 + 0.003 Mathematical equation: $ 0.182^{+0.003}_{-0.004} $ 0.345 ± 0.001
σv (km/s) < 300 < 200 900 500 + 900 Mathematical equation: $ 900^{+900}_{-500} $ < 300
kTcie (keV) 1 . 9 0.2 + 0.3 Mathematical equation: $ 1.9^{+0.3}_{-0.2} $ 1 . 62 0.10 + 0.13 Mathematical equation: $ 1.62^{+0.13}_{-0.10} $ 1.2 ± 0.1 1 . 70 0.13 + 0.30 Mathematical equation: $ 1.70^{+0.30}_{-0.13} $
L X cie ( 10 38 erg / s ) Mathematical equation: $ \mathrm{L}_{\mathrm{X}}^{\mathrm{cie}}\, (10^{38} \mathrm{erg/s}) $ 5 ± 2 5.3 ± 0.4 4.0 ± 1.1 6 2 + 3 Mathematical equation: $ 6^{+3}_{-2} $
ΔC-stat 10 32 18 10

Notes. cie0, cieB, and cieR refer to the rest-frame, blueshifted, and redshifted cie components, respectively. The X-ray luminosities are computed in the 0.3 − 10 keV energy range. (a)indicates fixed parameters.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.