Open Access

Table 1.

Limiting surface brightness calculated in boxes of 3 × 3 arcsec2, ICL fractions computed with CICLE, and breakdown of the ICL fraction error into the three sources considered.

Filter Surface brightness limit ICL fraction Errors

Photometric Cluster membership Geometrical
(mag arcsec−2) (%) (%) (%) (%)
F606W 27.55 ± 0.08 36.3 ± 5.0 2.5 0.9 1.6
F814W 27.32 ± 0.10 26.6 ± 1.6 0.9 0.6 0.2
F105W 27.00 ± 0.24 23.3 ± 1.7 0.5 0.5 0.8
F125W 26.48 ± 0.24 22.5 ± 0.9 0.5 0.4 0.0
F140W 26.58 ± 0.26 16.6 ± 3.2 0.3 0.3 2.5
F160W 27.00 ± 0.30 21.0 ± 1.2 0.4 0.4 0.4

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.