Open Access
Table 3.
Parameters obtained for our polarization analysis using the Compton mode.
Source | State period | Exposure time | Energy band | Signal | a100 | χ2/d.o.f. | punpola | Polarization | Polarization | Polarization |
---|---|---|---|---|---|---|---|---|---|---|
[Ms] | to noise ratio | [%] | Angle [°] | fraction [%] | detected | |||||
MAXI J1535 − 571 | HIMS | 0.22 | 300–400 keV | 4.9 | 0.278 | C = 2.35/5 | – | – | – | × |
S = 1.52/4 | ||||||||||
400–1000 keV | 7.2 | 0.194 | C = 1.30/5 | – | – | – | × | |||
S = 0.64/4 | ||||||||||
300–1000 keV | 8.7 | 0.224 | C = 1.35/5 | – | – | – | × | |||
S = 0.92/4 | ||||||||||
SIMS | 0.16 | 300–400 keV | 3.3 | 0.278 | C = 8.00/5 | – | – | – | × | |
S = 5.60/4 | ||||||||||
400–1000 keV | 3.7 | 0.194 | C = 2.00/5 | – | – | – | × | |||
S = 2.72/4 | ||||||||||
300–1000 keV | 4.9 | 0.224 | C = 6.35/5 | – | – | – | × | |||
S = 6.40/4 | ||||||||||
MAXI J1820+070 | LHS | 1.3 | 300–400 keV | 71 | 0.278 | C = 12.05/5 | 0.57 | 120 ± 14 | 17 ± 8 | ✓ |
S = 6.44/4 | ||||||||||
400–1000 keV | 67 | 0.194 | C = 13.1/5 | 0.11 | 105 ± 11 | 35 ± 12 | ✓ | |||
S = 4.48/4 | ||||||||||
300–1000 keV | 94 | 0.224 | C = 20.65/5 | 0.003 | 110 ± 11 | 26 ± 9 | ✓ | |||
S = 7.44/4 | ||||||||||
MAXI J1348 − 630 | LHS | 0.32 | 300–400 keV | 22.9 | 0.278 | C = 12.30/5 | 0.02 | 160 ± 9 | 75 ± 26 | ✓ |
S = 0.84/4 | ||||||||||
400–1000 keV | 22 | 0.194 | C = 9.40/5 | 0.06 | 180 ± 10 | > 70 | ✓ | |||
S = 5.28/4 | ||||||||||
300–1000 keV | 30.7 | 0.224 | C = 15.45/5 | 0.008 | 180 ± 10 | 79 ± 23 | ✓ | |||
S = 0.68/4 | ||||||||||
IMS | 0.17 | 300–400 keV | 8.2 | 0.278 | C = 13.15/5 | – | – | – | × | |
S = 12.84/4 | ||||||||||
400–1000 keV | 7.2 | 0.194 | C = 4.95/5 | – | – | – | × | |||
S = 3.88/4 | ||||||||||
300–1000 keV | 10.42 | 0.224 | C = 7.45/5 | – | – | – | × | |||
S = 6.32/4 | ||||||||||
HSS | 0.42 | 300–400 keV | 2.79 | 0.278 | C = 3.15/5 | – | – | – | × | |
S = 0.48/4 | ||||||||||
400–1000 keV | 3.01 | 0.194 | C = 11.01/5 | – | – | – | × | |||
S = 4.08/4 | ||||||||||
300–1000 keV | 4.12 | 0.224 | C = 5.55/5 | – | – | – | × | |||
S = 1.32/4 |
Notes. C and S are the values of the obtained using a constant (C) or a sinusoïdal (S) function for our polarigram fit.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.