Free Access

Table B.2.

Number of robust candidate resonances that involve the 𝒩i largest-amplitude signals for each star in our sample, and the priorities for non-linear asteroseismic follow-up.

KIC 𝒩i priority
3 5 10 15
003240411 0/0 0/0 1/1 0/0 low
003459297 1/1 1/1 1/1 0/0 low
003756031 3/8 2/6 X (H) X (H) medium
003839930 0/0 0/0 3/4 2/2 medium
003865742 1/6 0/3 0/1 X (H) medium
004930889 0/5 0/6 X (H) X (H) low
004936089 2/2 1/1 0/0 1/1 high
004939281 0/0 0/0 X (*) X (*) low
005084439 5/5 2/2 X (H) X (H) medium
005309849 4/7 5/7 4/6 X (H) medium
005941844 3/8 3/9 1/6 1/3 high
006352430 5/10 X (H) X (H) X (H) medium
006462033 0/0 X (H) X (H) X (H) low
006780397 1/6 1/10 X (H) X (H) medium
007630417 2/6 2/10 4/10 3/7 high
007760680 1/2 3/4 3/3 X (H) medium
008057661 3/7 3/10 X (H) X (H) medium
008087269 3/4 X (H) X (H) X (H) medium
008255796 0/12 0/9 0/4 X (H) low
008324482 3/4 3/3 3/4 3/4 high
008381949 1/3 2/5 2/6 3/6 medium
008459899 1/2 1/3 1/2 X (H) low
008714886 6/12 7/12 6/10 5/8 high
008766405 11/17 12/18 10/11 7/7 high
009020774 0/1 1/2 X (H) X (H) low
009227988 0/3 0/1 X (H) X (H) low
009715425 0/0 1/1 X (H) X (H) low
009964614 1/4 1/4 3/7 X (H) low
010220209 0/0 0/0 0/0 0/0 low
010285114 1/1 2/2 1/1 0/0 low
010526294 5/6 3/4 2/3 1/3 high
010536147 1/9 0/5 X (H) X (H) medium
010658302 1/1 1/1 1/1 3/4 medium
011152422 2/4 2/6 X (H) X (H) low
011360704 2/11 2/14 0/11 X (H) low
011454304 1/1 1/1 1/1 1/1 medium
011971405 1/1 1/2 1/3 0/1 low
012258330 3/7 1/4 2/6 3/4 high

Notes. We let 𝒩i be equal to 3, 5, 10, and 15. The priority for non-linear asteroseismic follow-up is indicated in the column ‘priority’. Similar to Table 4, the numbers of identified robust candidate resonances are displayed on the right side of ‘/’, whereas the numbers on the left side indicate how many of those robust candidate resonances have S/N ≥ 5. The font style of the KIC numbers is the same as that in Table 4. The symbol ‘X’ is used to denote those cases for which the hyperparametrisation exercise is not performed, because:

(H)

Higher-order candidate resonances are identified (i.e. o >  2).

(*)

Iterative pre-whitening strategy 4 delivers a model in which the number of extracted frequencies is lower than 𝒩i.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.