Free Access

Table 6

Spectral fit results for A1 (MCSNR J05366913).

Component Parameter Value

Model: simple vpshock

vphabs NH,LMC (1022 cm-2) 0.36 (0.32–0.40)a,d
vpshock b kT 3.61 (3.32–3.83)
O (Z/Z) 7.20 (4.41–8.63)
Ne (Z/Z) 4.73 (2.70–5.50)
Mg (Z/Z) 9.89 (>6.07)
Si (Z/Z) 8.16 (>4.82)
τu (1010 s cm-3) 1.77 (1.56–2.05)
norm (10-6 cm-5) 1.84 (1.64–3.13)
Fit statistic 1.19

Model: ejecta + ISM

vphabs NH,LMC (1022 cm-2) 0.46 (0.41–0.50)a,d
vpshock (ejecta) kT 4.09 (3.64–4.41)
O (104Z/Z) 1.00 (fixed)
Ne (104Z/Z) 0.38 (0.31–0.48)
Mg (104Z/Z) 0.71 (0.56–0.93)
Si (104Z/Z) 0.27 (0.17–0.46)
τu (1010 s cm-3) 9.70 (6.00–11.40)
norm (10-9 cm-5) 3.96 (2.36–5.70)
LXc (1034 erg s-1) 3.3
vpshock (ISM) kT 2.71 (1.70–3.81)
τu (1010 s cm-3) 0.59 (0.50–0.67)
norm (10-5 cm-5) 1.89 (1.39–2.48)
LXc (1034 erg s-1) 5.1
Fit statistic 1.16

Notes. See text for description of the models.

(a)

Absorption component abundances fixed to those of the LMC.

(b)

Only O, Ne, Mg, and Si allowed to vary. All other metal abundances fixed to the LMC value of 0.5 Z/Z (Russell & Dopita 1992).

(c)

De-absorbed 0.310 keV X-ray luminosity, adopting a distance of 50 kpc to the LMC.

(d)

The numbers in parentheses are the 90% confidence intervals.