Planck 2013 results
Free Access

Table 2

Summary of systematic effects uncertainties on mapsa in  μKCMB.

30 GHz 44 GHz 70 GHz

p-p rms p-p rms p-p rms
Bias fluctuations ......... 0.08 0.01 0.10 0.02 0.23 0.06
Thermal fluctuations ......... 0.61 0.11 0.40 0.08 1.17 0.20
1 Hz spikes ......... 0.87 0.17 0.14 0.03 0.60 0.12
Sidelobes pick-up ......... 18.95 4.53 1.92 0.57 6.39 1.91
ADC non-linearity ......... 3.87 1.01 0.89 0.19 0.92 0.19
Calibration ......... 4.33 1.16 4.74 0.97 6.51 1.10
Totalb ......... 21.02 4.83 5.61 1.13 7.87 2.00

Notes.

(a)

Calculated on a pixel size approximately equal to the average beam FWHM.

(b)

The total has been computed on maps resulting from the sum of individual systematic effect maps.