Issue |
A&A
Volume 530, June 2011
|
|
---|---|---|
Article Number | A147 | |
Number of page(s) | 11 | |
Section | Extragalactic astronomy | |
DOI | https://doi.org/10.1051/0004-6361/201015247 | |
Published online | 26 May 2011 |
Megamaser detection and nuclear obscuration in Seyfert galaxies⋆
1
Astronomisches Institut, Ruhr–Universität Bochum,
Universitätsstraße 150,
44801
Bochum, Germany
e-mail: ramolla@astro.rub.de
2
Department of Physics, University of California,
Santa Barbara, CA
93106,
USA
3
Facultad de Ciencias, Universidad Católica del
Norte, Antofagasta,
Chile
Received:
21
June
2010
Accepted:
3
February
2011
We revisit the relation between H2O maser detection rate and nuclear obscuration for a sample of 114 Seyfert galaxies drawn from the CfA, 12 μm, and IRAS F25/F60 catalogs. These sources have mid-infrared spectra from the Spitzer Space Telescope and we search for accompanying X-ray and [O III] 5007 Å fluxes from the literature. We use the strength of the [O IV] 25.9 μm emission line as a tracer of the intrinsic AGN strength. After the normalization by [O IV], the observed X-ray flux provides information about X-ray absorption. The distribution of X-ray/[O IV] flux ratios is significantly different for masers and non-masers: The maser detected Seyfert-2s (Sy 1.8–2.0) populate a distinct X-ray/[O IV] range, which is, on average, about a factor of four lower than the range of Seyfert-2 non-masers and about a factor of ten lower than the range of Seyfert-1s (Sy 1.0–1.5). Non-masers are almost equally distributed over the entire X-ray/[O IV] range. This provides evidence that high nuclear obscuration plays a crucial role in determining the probability of maser detection. Furthermore, after normalization with [O IV], we find a similar but weaker trend for the distribution of the maser detection rate with the absorption of the 7 μm dust continuum. This suggests that the obscuration of the 7 μm continuum occurs on larger spatial scales than that of the X-rays. Hence, in the AGN unified model, at moderate inclinations away from edge-on, the 7 μm dust absorption may occur without any proportionate X-ray absorption. The absorption of [O III] appears unrelated to maser detections. The failure to detect masers in obscured AGN is most likely due to insufficient observational sensitivity.
Key words: galaxies: Seyfert / galaxies: nuclei / masers / X-rays: galaxies / infrared: galaxies
Full Table 1 is only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/530/A147
© ESO, 2011
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.