Table 3
Parameter settings for the double-absorbed bvapec model, with the parameter name and whether it is free or fixed.
| Parameter name | Free | Range |
|---|---|---|
| nH | False | [0.02] |
| kT | True | 𝒰(0.5, 5) |
| He-Ni | False | [1] |
| Redshift | True | 𝒰(0.05, 0.2) |
| Velocity | False | [100] |
| norm | True | log-𝒰(0.01, 10) |
| kT | True | 𝒰(0.5, 5) |
| He-Ni | False | [1] |
| Redshift | False | Tied |
| Velocity | False | [100] |
| norm | True | log-𝒰(0.01, 10) |
Notes. Fixed parameters have their values given in brackets, while free parameters list the prior type — either uniform 𝒰 or log-uniform log 𝒰 — and the range of variation in parentheses, and the abundances from He to Ni are set to their default values.