Euclid on Sky
Open Access

Table 4

Readout parameters for spectroscopy and photometry in the reference observing sequence (ROS).

g r d tint [s] texp [s]
Spectroscopy 15 16 11 549.6 574.4
Photometry 4 16 4 87.2 112.0

Notes. MACC(g,r,d) mode parameters for spectroscopy and photometry in the ROS. Here, g is the number of groups in the slope fit, r the number of reads per group, and d the number of drops after each but the last group. Both grisms use the same MACC settings, as do all three photometry bands. For both MACC modes the integration time tint (effective time accumulating light; the time relevant for science) and exposure time texp (total duration of frame including one reset frame before start of charge integration; the time relevant for exposure planning) are given, using the frame duration of 1.45408 s.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.