Open Access

Table A.1.

Emission line fluxes and main line ratios measured for cubes at different stages of reduction.

cube0 cube1 cube2 cube3
F(Hα) [10−18] 3.85 ± 0.23 (+0.8%) 4.09 ± 0.18 (+7.1%) 3.82 ± 0.15 3.82 ± 0.15 (+0.0%)
F(Hβ) [10−18] 1.52 ± 0.13 (+4.8%) 1.56 ± 0.10 (+7.6%) 1.45 ± 0.09 1.36 ± 0.08 (−6.2%)
F([O III]λ5007) [10−18] 6.11 ± 0.37 (+3.2%) 6.07 ± 0.28 (+2.5%) 5.92 ± 0.23 5.54 ± 0.22 (−6.4%)
F([O III]λ4959) [10−18] 2.18 ± 0.15 (+4.8%) 2.12 ± 0.12 (+1.9%) 2.08 ± 0.11 1.94 ± 0.10 (−6.7%)
Hα/Hβ 2.54 ± 0.27 (−3.8%) 2.62 ± 0.20 (−0.8%) 2.64 ± 0.19 2.81 ± 0.20 (+6.4%)
[O III]λ5007/Hβ 4.03 ± 0.42 (−1.5%) 3.89 ± 0.30 (−4.9%) 4.09 ± 0.29 4.06 ± 0.29 (−0.7%)

Notes. Cube0 is the cube fully-reduced (including background subtraction) with the standard JWST-NIRSpec pipeline; cube1 includes the post-processing but only a scalar-median background treatment; cube2 includes post-processing and the final background subtraction; in addition to the latter, cube3 also includes the PSF correction. Relative differences, with respect to cube2, are given within parenthesis, in % values. We remind that cube3 is the final version used in the analyses of the main text; nevertheless, cube2 offers a more direct reference for comparison among the other non-PSF corrected cubes. All values in the table refer to spectra measured within the D1 mask; see Fig. 2.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.