Open Access

Table 3.

Best-fit parameters for Chandra/HETG spectrum of EXO 2030+375.

Parameter Value
NH(a) 2 . 26 0.07 + 0.06 $ 2.26^{+0.06}_{-0.07} $
FPL(b) 4.49 ± 0.03
Γ 1 . 05 0.05 + 0.06 $ 1.05^{+0.06}_{-0.05} $
kTBB(c) 0 . 63 0.06 + 0.04 $ 0.63^{+0.04}_{-0.06} $
FBB(b) 0.28 ± 0.02
ESi XIV Lyα(c) 2.41 ( † )
ASi XIV Lyα(d) 0 . 74 0.30 + 0.29 $ 0.74^{+0.29}_{-0.30} $
EFe Kα(c) 6.40 (†)
AFe Kα(d) 0 . 27 0.18 + 0.22 $ 0.27^{+0.22}_{-0.18} $
EFe XXV Heα(c) 6.70 ( † )
AFe XXV Heα(d) 0 . 42 0.24 + 0.25 $ 0.42^{+0.25}_{-0.24} $
EFe XXVI Lyα(c) 6.97 ( † )
AFe XXVI Lyα(d) < 0.38

Notes. All line widths were fixed to 10 eV.

(a)

In 1022 cm−2.

(b)

Unabsorbed 0.1–10 keV flux in 10−9 erg s−1 cm−2.

(c)

In keV.

(d)

Photon flux in 10−3 phs cm−2 s−1.

(†)

Kept frozen during the fit.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.