Press Release
Open Access

Table D.5

Posterior of the light curve fits for Spitzer

Dataset and model
Parameter IRACI IRAC1&2 (Κelp,therm) ΙRΑC2 (Cos) ΙRΑC2 (Κelp,therm)
Orbital model
ρ*] 0.2807 ± 0.0071 0.2849 ± 0.0038 0.2842 ± 0.0037
Ρ [days] 1.80988010 ± 5.610−7 1.80988074 ± 5.2 10−7 1.80988165 ± 6.010−7 1.80988164 ± 5.9 10−7
tic [TBJD] 1051.66373 ± 0.00012 859.81519 ±0.00016
cos i (6.60 ± 0.59) 10−3 (6.58 ± 0.58) 10−3 (6.60 ± 0.56) 10−3
a/R* 4.092 ± 0.018 4.1180 ± 0.0098
e cos ω 0.001507 ± 0.00025 0.00205 ± 0.00029
e sin ω −0.0001 ± 0.0045 0.0013 ± 0.0025
e
ω [deg]
Transit model
Rp/R* (IRACI) 0.10735 ± 0.00027 0.10684 ±0.00027 - -
Rp/R* (IRAC2) - 0.10988 ± 0.00037 0.10985 ± 0.00034 0.10989 ±0.00034
u1 (IRACI) 0.0574 ± 0.0050 - -
u1 (ΙRΑC2) - 0.0575 ± 0.0083 0.0573 ± 0.0082
u2 (IRACI) 0.4827 ± 0.0040 - -
u2 (ΙRΑC2) - 0.3716 ±0.0087 0.3706 ± 0.0086
u3 (IRACI) −0.4427 ± 0.0028 - -
u3 (ΙRΑC2) - −0.3419 ± 0.0036 −0.3405 ± 0.0038 −0.3406 ± 0.0037
u4 (IRACI) 0.1359 ± 0.0020 - -
u4 (ΙRΑC2) - 0.1066 ±0.0011 0.1061 ±0.0011 0.1061 ±0.0011
Occultation model when not part of a phase curve
Fp/F* [ppm] (IRACI) - -
Fp/F*. [ppm] (ΙRΑC2) -
Phase curve model: Cos
A0 [ppm] - - 2174 ± 46 -
Fn [ppm] (ΙRΑC2) - - 1459 ± 47 -
ϕ0 [deg] - - −0.5 ± 1.1 -
Phase curve model: Κelp,therm
C1,1 (IRACI) - - -
C1,1 (ΙRΑC2) - 0.2184 ± 0.0059 -
ƒ′ - - 0.6820 ± 0.0057
ϕΚelp - - −3.4 ± 1.0
Instrumental model
c (IRACI) 0.0946 ± 0.0019 - -
c (ΙRΑC2) - 0.0925 ± 0.0026 0.0912 ± 0.0025
σinst [ppm] (IRACI) <350 <220 - -
σinst [ppm] (ΙRΑC2) <80 <140 <140

  • As mentioned in Section 4.2, when an estimate and uncertainty are provided, it corresponds to the median and the 68% confidence interval estimated with the 16th and 84th percentiles of the posterior probability density function. When an upper limit is provided, it corresponds to the 99.7th percentile.

  • We chose not to provide the instrumental offset (ΔF/F), in this table. There is one such offset for each dataset. This corresponds to 7 offsets for IRACI, 3 for IRAC2. This will overcrowd the table. Furthermore, the value of these parameters doesn't carry a lot of information

(a) The posterior distribution of the eccentricity peaks slightly before 0. For this reason, we provide both the estimate with its 68% confidence interval and the upper limit at 99.7% confidence.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.