Press Release
Open Access

This article has an erratum: [https://doi.org/10.1051/0004-6361/202450465e]


Table 2.

Calibration parameters used in DDECal at different stages of the analysis.

Parameter Bandpass calibration A-team subtraction 3C subtraction NCP subtraction
Input data level L1 L2 L2 L3
Output data level L2 L2 L3 L4
Mode Diagonal Diagonal Diagonal Diagonal
Time interval 4 s 2 min 4 min 8 min
Frequency interval 15.3 kHz 195.3 kHz 195.3 kHz 195.3 kHz
Directions Cas A Four A-team sources and NCP Seven 3C sources and NCP 7 Clusters
Smoothness constraint None 2 MHz 2 MHz 6 MHz
uv range > 15λ > 20λ > 40λ > 40λ

Notes. L1 data have a 15.26 kHz frequency resolution while L2, L3 and L4 data have 61.03 kHz frequency resolution. The time resolution for L1, L2, L3 and L4 data levels is 4 s.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.