Open Access

Table 3

Utilized models.

Model Energy bands
Ml: constant×TBabs×Smedge×(simpl⊛diskbb) 2–10 keV (LE), 10–30 keV (ME)
M2: constant×TBabs×Smedge×(Thcomp⊛diskbb) 2–10 keV (LE), 10–30 keV (ME)
M3: constant×TBabs×Smedge×(Thcomp⊛kerrbb2) 2–10 keV (LE), 10–30 keV (ME)
M4: constant×TBabs×Smedge×(Thcomp⊛slimbh) 2–8 keV (LE), 10–30 keV (ME)
M5: TBabs×edge×Smedge×slimbh 2–9 keV (NICER)

Notes. Spectral fitting with models M1–M2 were performed with Insight-HXMT. Spin extraction with Models M3–M5 utilized both Insight-HXMT (M3-M4) and NICER (M5). Because all of the ‘golden’ observations of Insight-HXMT selected for spin measurement suffered from the photoelectric effect between 8–10 keV, we have restricted LE to 2–8 keV during the final spin estimate (M4). This was also done in the case of M1 & M2 when measuring the spectral evolution on these observations.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.