Table 2.
Summary of the diagnostic line list.
Line identifier | λ Fitting range (Å) |
Line components | |
---|---|---|---|
V382 Cyg | SMC 108086 | ||
Hδ | 4082.0–4111.8 | 4085.1–4117.1 | H I 4101.734, He II 4101.198, N III 4097.35, 4103.43, Si IV 4088.862 |
Hγ | 4327.6–4358.8 | 4329.2–4359.4 | H I 4340.472, He II 4339.891, Si IV 4328.177 |
Hβ | 4846.8–4874.0 | 4849.8–4879.7 | H I 4861.35, He II 4861.35 |
Hα | 6546.6–6578.5 | 6534.4–6594.7 | H I 6562.79, He II 6562.79 |
He I 4121 | 4112.4–4126.4 | 4117.0–4129.2 | He I 4120.815, Si IV 4116.104 |
He I 4143 | 4137.2–4152.9 | 4137.4–4156.4 | He I 4143.761 |
He I 4387 | 4382.5–4395.6 | 4381.9–4399.1 | He I 4387.930 |
He I 4471 | 4462.0–4479.8 | 4464.4–4485.7 | He I 4471.480 |
He I 4713 | 4704.7–4720.5 | 4706.2–4726.0 | He I 4713.145 |
He I 4922 | 4912.7–4931.7 | 4914.7–4936.3 | He I 4921.931 |
He I 5016 | 5007.8–5023.8 | 5008.6–5027.5 | He I 5015.678 |
He I 5875 | 5863.2–5883.9 | – | He I 5875.621 |
He I 6678 | 6667.0–6696.1 | 6664.7–6703.8 | He I 6678.151, He II 6685.046 |
He II 4200 | 4189.8–4209.8 | 4188.5–4214.8 | He II 4199.870, N III 4195.76, 4200.10 |
He II 4541 | 4530.2–4553.2 | 4529.9–4560.6 | He II 4541.625 |
He II 4686 | 4675.8–4696.1 | 4676.0–4702.0 | He II 4685.742 |
He II 5411 | 5397.5–5428.0 | 5399.9–5432.1 | He II 5411.554 |
C III 4069 | 4064.5–4078.7 | 4065.7–4081.8 | C III 4067.940, 4068.916, 4068.916, 4070.260 |
C III 4187 | 4177.5–4189.6 | 4180.6–4192.8 | C III 4186.900 |
C III 4650 | 4647.1–4657.1 | 4645.4–4659.8 | C III 4647.418, 4650.246, 4651.473 |
C IV 5801 | 5788.8–5823.7 | 5793.2–5828.1 | C IV 5801.33, 5811.98 |
N III 4379 | 4375.6–4382.3 | 4378.7–4383.4 | N III 4378.93, 4379.11 |
N III 4515 | 4508.7–4521.2 | 4512.1–4524.6 | N III 4514.854, 4510.965, 4510.885, 4518.143 |
N III 4640 | 4629.4–4645.5 | 4632.8–4645.8 | N III 4634.122, 4640.641, 4641.850 |
N IV 4058 | 4052.7–4063.8 | 4055.8–4066.9 | N IV 4057.76 |
O III 5592 | 5581.5–5602.8 | 5585.7–5607.0 | O III 5592.252 |
Notes. The main identifier is given in Col. 1, although we note that some of these lines contain blends. The adopted fitting ranges per line are provided in Cols. 2 and 3 for V382 Cyg and SMC 108086, respectively. All of the individual line components that are included in the calculations of each line are indicated in Col. 4.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.