Free Access

Table 3

Comparison of the integrated intensities and integrated absorbance of our variational calculation (this work) with the empirical HITRAN and the experimental PNNL databases.

Integrated intensities (in cm/molecule) Integrated absorbance
Region (cm-1) CB HB CB+HB HT2012 This work PNNL

(I) 6001200 1.35E-17 8.43E-19 1.44E-17 1.29E-17 2.54E-1 2.62E-1
Nb of lines 38 753 32 6118 36 4871 5816
(II) 12001600 1.61E-18 8.99E-20 1.70E-18 1.59E-18 3.01E-2 3.07E-2
Nb of lines 12 215 80 675 92 890 5400
(III) 16002750 9.68E-19 7.03E-20 1.04E-18 / 1.833E-2 1.89E-2
Nb of lines 96 027 22 8905 32 4932 /
(IV) 27503450 6.64E-18 3.53E-19 6.99E-18 5.78E-18 1.24E-1 1.23E-1
Nb of lines 10 8458 40 4403 51 2861 6881
(V) 34504050 3.39E-20 1.49E-21 3.53E-20 / /a
Nb of lines 99 769 44 763 14 4532 /
(VI) 40505200 1.01E-18 4.87E-20 1.06E-18 / 1.87E-2 1.86E-2
Nb of lines 40 6188 41 6116 82 2304 /
(IVI)6005200 2.38E-17 1.41E-18 2.52E-17 2.02E-17 4.45E-1 4.53E-1
Nb of lines 76 1410 15 00980 22 62390 18 097

Notes. Contribution of the cold (CB) and hot (HB) bands is also listed.

(a)

See Sect. 4.5 for explanation.