Highlight
Free Access

Table D.1

Best fit XSPEC models.

Clustera T1 [keV]b T2 [keV]b Z [Z]b n1 [10-2 cm-5]b n2 [10-2 cm-5]b b d.o.f.b

1e0657i 12.5 ± 0.48 0.49 ± 0.189 1.11 ± 0.031 1.20 200
a1795i 2.5 ± 0.35 6.4 ± 0.39 0.42 ± 0.026 1.02 ± 0.348 3.57 ± 0.343 1.08 199
a1795s 3.1 ± 0.45 7.4 ± 0.59 0.46 ± 0.034 1.75 ± 0.454 3.01 ± 0.460 1.04 199
a1995i 6.8 ± 0.97 0.25 ± 0.194 0.18 ± 0.120 1.00 84
a1995s 6.6 ± 0.88 0.78 ± 0.665 0.19 ± 0.129 1.10 87
rxj1347i 4.2 ± 1.93 16.2 ± 2.76 0.27 ± 0.050 0.23 ± 0.143 1.08 ± 0.061 0.90 199
rxj1347s 11.2 ± 1.33 0.31 ± 0.055 1.25 ± 0.182 0.90 163
zw3146i 0.5 ± 0.70 6.9 ± 1.02 0.30 ± 0.295 0.90 ± 4.692 1.01 ± 0.105 1.05 199
a1835i 4.1 ± 2.50 8.8 ± 1.71 0.38 ± 0.207 0.36 ± 0.602 1.21 ± 0.401 1.12 199
a1835s 2.1 ± 1.21 11.9 ± 4.67 0.08 ± 0.151 0.75 ± 0.394 1.29 ± 0.232 0.92 198
a665i 4.6 ± 3.04 15.4 ± 10.09 0.39 ± 0.397 0.24 ± 0.276 0.24 ± 0.306 1.03 199
a520i 8.1 ± 0.30 0.73 ± 0.276 0.37 ± 0.027 1.07 200
a1689i 10.7 ± 0.80 0.44 ± 0.254 1.66 ± 0.075 1.15 200
ms1455i 3.4 ± 1.87 6.1 ± 3.24 0.10 ± 0.203 0.34 ± 0.757 0.40 ± 0.767 1.07 198
a401i 8.9 ± 0.42 0.44 ± 0.152 2.95 ± 0.089 1.23 200
a1413i 1.4 ± 0.77 8.9 ± 1.37 0.83 ± 0.336 0.09 ± 0.137 0.96 ± 0.049 1.09 199
a2146i 2.5 ± 2.73 7.1 ± 1.21 0.54 ± 0.198 0.05 ± 0.184 0.48 ± 0.132 0.98 199
a2146s 1.4 ± 1.03 8.6 ± 2.88 0.32 ± 0.381 0.21 ± 0.296 0.47 ± 0.155 0.94 169
a521i 6.4 ± 1.12 1.78 ± 1.961 0.08 ± 0.105 0.88 109
a521s 8.2 ± 1.65 0.01 ± 1.534 0.13 ± 0.116 1.15 55
ms0735i 4.9 ± 0.66 0.77 ± 0.239 0.34 ± 0.053 1.05 199
ms0735s 2.5 ± 3.72 5.5 ± 2.75 0.43 ± 0.385 0.08 ± 0.524 0.31 ± 0.434 1.02 157
pks0745i 2.7 ± 0.64 11.9 ± 5.97 0.68 ± 0.271 1.83 ± 1.055 4.10 ± 0.616 1.03 199
pks0745s 2.7 ± 0.68 9.4 ± 0.78 0.53 ± 0.074 1.27 ± 0.410 5.10 ± 0.367 1.04 199
a2204i 2.0 ± 0.27 13.7 ± 3.27 0.47 ± 0.157 1.03 ± 0.213 2.02 ± 0.149 1.06 199
a2204s 1.7 ± 0.89 8.8 ± 3.26 0.70 ± 0.511 0.56 ± 0.822 2.43 ± 0.326 1.05 192
a2034i 1.4 ± 0.39 12.9 ± 2.63 0.25 ± 0.122 0.21 ± 0.125 0.63 ± 0.038 0.94 199
cygnusai 1.5 ± 0.42 7.4 ± 0.36 0.86 ± 0.111 0.31 ± 0.158 3.64 ± 0.094 0.90 199
cygnusas 2.5 ± 0.40 11.6 ± 3.47 0.68 ± 0.145 1.32 ± 0.450 2.98 ± 0.265 0.99 199
a907i 3.7 ± 2.94 7.2 ± 2.90 0.40 ± 0.218 0.33 ± 0.756 0.41 ± 0.710 0.88 199
a3667i 3.2 ± 0.50 10.6 ± 1.37 0.22 ± 0.065 0.92 ± 0.226 1.54 ± 0.207 0.90 199
2a0335s 1.4 ± 0.39 3.4 ± 0.24 0.67 ± 0.042 1.69 ± 0.831 5.23 ± 0.841 1.41 199
a2597s 0.8 ± 1.28 3.7 ± 0.10 0.43 ± 0.058 0.14 ± 0.668 1.91 ± 0.063 0.98 199
a1650i 2.8 ± 2.31 7.3 ± 1.10 0.45 ± 0.102 0.32 ± 0.560 1.25 ± 0.377 0.85 199
a1650s 4.3 ± 1.63 6.9 ± 2.96 0.63 ± 0.205 0.81 ± 1.128 0.78 ± 1.141 1.09 199
a2199i 3.0 ± 0.49 5.9 ± 1.02 0.41 ± 0.048 3.35 ± 1.251 2.91 ± 1.271 0.89 199
a2199s 2.0 ± 0.36 6.1 ± 1.01 0.38 ± 0.058 2.23 ± 1.003 4.74 ± 0.895 0.96 199
hydraai 3.7 ± 0.14 0.83 ± 0.599 2.54 ± 0.428 1.55 199
hydraas 1.4 ± 1.00 4.0 ± 0.22 0.38 ± 0.036 0.36 ± 0.467 3.42 ± 0.333 1.06 199
a496s 2.1 ± 0.14 7.1 ± 0.59 0.87 ± 0.082 1.10 ± 0.223 3.32 ± 0.172 1.06 199
sersic159i 2.2 ± 0.27 3.9 ± 1.94 0.38 ± 0.058 1.28 ± 0.752 0.58 ± 0.916 1.14 199
sersic159s 2.0 ± 0.81 4.3 ± 5.23 0.46 ± 0.154 1.17 ± 1.722 0.66 ± 1.958 1.12 131
3c348s 2.6 ± 1.11 4.7 ± 1.62 0.75 ± 0.221 0.12 ± 0.385 0.27 ± 0.322 0.98 196
a1775s 2.3 ± 1.12 5.7 ± 3.89 0.57 ± 0.149 0.20 ± 0.346 0.19 ± 0.339 1.08 191
a2052s 1.5 ± 0.23 3.4 ± 0.12 0.67 ± 0.029 0.48 ± 0.171 1.96 ± 0.126 1.02 199
a2744i 10.2 ± 1.65 0.31 ± 0.359 0.46 ± 0.093 1.02 200
a2744s 10.9 ± 2.52 0.93 ± 1.381 0.43 ± 0.268 0.87 122
a2390s 5.4 ± 5.40 10.3 ± 2.40 0.95 ± 0.305 0.26 ± 0.998 1.02 ± 0.612 0.92 199
mergei 2.8 ± 0.85 7.3 ± 0.34 0.56 ± 0.099 0.30 ± 0.165 1.54 ± 0.130 1.11 130
merges 2.2 ± 0.21 5.8 ± 0.32 0.70 ± 0.063 0.97 ± 0.182 2.17 ± 0.155 1.41 130

Notes.

(a)

Abbreviated cluster name and detector identifier (i: ACIS-I, s: ACIS-s). “merge” indicates the best fit to the merged spectra of the complete sample.

(b)

Best fit parameters of the XSPEC apec models to the individual cluster emission. Second temperature model was set to zero if temperatures T differed by less than 30 per cent or second normalisation n was less than one per cent of the first model. Metallicity Z was linked between the two models. The goodness of fit is give as with the degrees of freedom (d.o.f.) of the fit.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.