Free Access

Table 1

Spectroscopic parameters of the 15NH2 and 14NH2 radicals in their ground vibronic state.

Parameter in MHz 15NH2 14NH2a

Rotational and centrifugal distortion constants

A 704 388.406(45)b 710 302.019(10)
B 388 292.32(11) 388 289.458(15)
C 244 293.59(12) 245 013.520(11)
ΔK 649.370(34) 659.7470(33)
ΔNK –124.365(18) –125.1228(16)
ΔN 31.6626(24) 31.68194(44)
δ K 28.732(70) 29.6553(65)
δ N 12.7139(15) 12.70818(17)
ΦK 1.9178(28) 1.99230(42)
ΦKN –0.2739(27) –0.28242(48)
ΦNK -0.04960(89) –0.04888(15)
ΦN 0.012841(66) 0.0128969(81)
φ K 0.507(11) 0.52551(69)
φ NK –0.01624(33) –0.016015(67)
φN × 10-3 6.409(32) 6.4313(43)
LK × 10-3 –8.63(24) –10.665(22)
LKKN × 10-3 3.70( 37) 3.755(16)
LNK × 10-3 -1.03(15) –0.9976((57)
LNNK × 10-3 0.0615( 37) 0.057(14)
LN × 10-6 –6.80(56) –7.993(81)
lK × 10-3 –3.63(34) –4.145(15)
lKN × 10-6 108.4c 108.4(38)
lNK × 10-6 8.03c 8.03(35)
lN × 10-6 –3.45(29) –4.031(43)

Fine structure constants

ϵ aa –9188.74(10) –9267.840(26)
ϵ bb –1353.75(14) –1354.194(14)
ϵ cc 11.89(13) 12.220(15)
33.110(76) 34.0205(72)
+ –3.200(45) –3.4938(67)
15.7(22) 0.950(85)
0.3067(46) 0.31386(48)
0.451(45) 0.5667(51)
0.1474(24) 0.15716(24)
–0.1817(35) –0.19276(70)
0.0225(26) 0.02695(67)
–0.01032c –0.01032(69)
0.920c 0.920(13)
–0.144c –0.144(11)

Hyperfine structure constants

aF(N) –39.275(69) 28.066(10)
Taa(N) 60.34(15) –43.175(16)
Tbb(N) 62.19(11) –44.453(18)
Caa(N) –0.661(75) 0.4618(64)
Cbb(N) –0.161(32) 0.0941(52)
Ccc(N) –0.01501d 0.0107(37)
aF(H) –67.187(34) –67.184(11)
Taa(H) 18.577(76) 18.333(20)
Tbb(H) –13.248(62) –13.161(22)
Tab(H) 58.50e 58.50e
Caa(H) 0.2183c 0.2183(78)
Cbb(H) × 10-3 –6.8d –6.8(65)
Ccc(H) –0.0248d –0.0248(50)

Number of FT-FIR lines (62–227 cm-1) 142
Standard deviation of the FT-FIR data (in cm-1) 1.0 × 10-4
Number of submillimeter lines (150–660 GHz) 77
Standard deviation of the submillimeter data (in kHz) 115.5
13, 5
Weighted deviation of fit 0.88

Notes.

(a)

14NH2 parameters are from Martin-Drumel et al. (2014).

(b)

Number in parenthesis is one standard deviation in unit of the last digit.

(c)

Fixed at the 14NH2 value.

(d)

Fixed at the value from Gendriesch et al. (2001).

(e)

Fixed at the value from Steimle et al. (1980).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.