Table 8
Molecular hydrogen column densities as measured using K-band spectra (5 knots) and narrow-band H2 line imaging (29 knots).
Knot | N H2 | M H2 | Ṁout(H2) | n H2 |
MHO | (cm-2) | (M⊙) | (M⊙ yr-1) | (cm-3) |
|
||||
2234-A1+A2* | 1.5 ×1020 | 7.0 ×10-5 | 9.6 ×10-7 | 16900 |
(2.8 ×1019) | (1.3 ×10-5) | (1.9 ×10-7) | (3200) | |
2234-B1 | 2.2 ×1019 | 7.0 ×10-6 | 4.7 ×10-8 | 2500 |
2234-C | 3.7 ×1018 | 1.1 ×10-6 | 1.6 ×10-9 | 4300 |
2234-D1+D2* | 1.4 ×1018 | 6.4 ×10-7 | 1.5 ×10-9 | 200 |
(1.2 ×1018) | (5.6 ×10-7) | (1.4 ×10-9) | (100) | |
2234-E | 5.2 ×1017 | 2.1 ×10-7 | 3.9 ×10-10 | 60 |
2234-G1 | 7.7 ×1017 | 6.6 ×10-8 | 2.8 ×10-11 | 90 |
2234-H1* | 1.1 ×1019 | 5.0 ×10-6 | 3.0 ×10-9 | 1300 |
(8.4 ×1018) | (3.9 ×10-6) | (2.4 ×10-9) | (1000) | |
2234-H2 | 3.6 ×1018 | 1.0 ×10-6 | 3.0 ×10-10 | 400 |
2234-H3 | 2.4 ×1018 | 6.0 ×10-7 | 2.6 ×10-10 | 300 |
2234-H4 | 1.4 ×1018 | 2.6 ×10-7 | 9.7 ×10-11 | 200 |
2234-H5 | 2.3 ×1018 | 3.5 ×10-7 | 3.4 ×10-11 | 300 |
2234-H8 | 2.1 ×1018 | 4.3 ×10-7 | 1.1 ×10-10 | 300 |
|
||||
2233-N* | 4.4 ×1017 | 2.3 ×10-7 | 5.7 ×10-11 | 50 |
(1.6 ×1017) | (8.5 ×10-8) | (2.1 ×10-11) | (20) | |
2233-P | 9.2 ×1016 | 2.0 ×10-8 | 4.0 ×10-12 | 10 |
2235-A2 | 9.9 ×1017 | 1.4 ×10-7 | 8.1 ×10-11 | 100 |
2235-C1 | 1.1 ×1018 | 1.7 ×10-7 | 3.0 ×10-10 | 100 |
2235-D | 6.1 ×1017 | 7.4 ×10-8 | 6.5 ×10-11 | 70 |
2235-E | 1.4 ×1018 | 3.5 ×10-7 | 1.0 ×10-9 | 200 |
2235-F1 | 9.0 ×1017 | 1.2 ×10-7 | 1.8 ×10-10 | 100 |
2235-I1 | 5.2 ×1017 | 5.7 ×10-8 | 7.4 ×10-12 | 60 |
2235-I2 | 5.6 ×1017 | 5.9 ×10-8 | 2.2 ×10-11 | 60 |
2235-I3 | 3.0 ×1017 | 2.9 ×10-8 | 6.7 ×10-12 | 30 |
2235-K | 8.1 ×1017 | 1.3 ×10-7 | 2.7 ×10-11 | 90 |
2235-M1 | 8.5 ×1017 | 2.2 ×10-7 | 5.1 ×10-12 | 100 |
2235-M2 | 7.3 ×1017 | 1.7 ×10-7 | 1.1 ×10-11 | 80 |
2235-M4 | 7.4 ×1017 | 2.1 ×10-7 | 3.6 ×10-11 | 90 |
2235-M5 | 4.9×1017 | 5.0 ×10-8 | 2.8 ×10-11 | 60 |
|
||||
2235-A1 | 1.3 ×1018 | 6.5 ×10-7 | 1.2 ×10-9 | 200 |
2235-B* | 1.1 ×1019 | 8.0 ×10-6 | 4.8 ×10-9 | 1300 |
(4.8 ×1018) | (3.4 ×10-6) | (2.1 ×10-9) | (600) |
Notes.The masses are obtained from the column densities NH2 and the surface areas of the knots. The mass-loss rates are estimated using the velocity information of the knots and their location relative to the driving source.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.