Free Access

Table 1

H2O, OH, and 18OH lines detected with PACS.

Line λrest Vcab ΔV ac ΔVinferred d Continuume Peak line deptha Fluxa
(μm) (km s-1) (km s-1) (km s-1) (Jy) (Jy) (Jy km s-1)

H2O 422 → 313 57.636 −25(17) 319(43) 247 22.4 1.8(0.2) −613(108)
H2O 524 → 413 71.067 35(39) 275(98) 221 28.7 0.7(0.2) −204(93)
H2O 717 → 606 71.540 −12(65) 292(147) 243 29.0 0.5(0.2) −144(96)
H2O 707 → 616 71.947 5(33) 416(103) 383 29.3 0.8(0.2) −358(112)
H2O 321 → 212 75.381 20(4) 235(9) 178 30.9 6.4(0.2) −1595(76)
H2O 423 → 312 78.742 −1(8) 239(20) 190 31.2 3.8(0.3) −975(105)
H2O 616 → 505 82.031 −73(26) 264(73) 226 31.0 1.7(0.3) −464(158)
H2O 606 → 515 83.284 −49(25) 247(71) 207 31.2 1.3(0.3) −339(123)
H2O 221 → 110 108.073 −19(10) 366(26) 194 31.0 4.0(0.2) −1541(145)
H2O 313 → 202f 138.528 −4(16) 286(54) 109 27.8 2.4(1.0) −716(325)
H2O 313 → 202f 138.528 266(173) 508(219) 434 27.8 −1.1(0.4) 606(334)
OH 65.132 36(12) 283(30) 219 26.6 2.7(0.2) −817(111)
OH 65.279 19(13) 325(34) 271 26.6 2.4(0.2) −833(114)
OH 71.197 g 5(20) 365(53) 28.7 1.5(0.2) −596(111)
OH 79.118 −22(7) 148(18) 30.8 3.1(0.3) −483(76)
OH 79.181 −18(7) 125(19) 30.8 2.9(0.4) −384(75)
OH 84.420 12(4) 227(9) 185 31.4 7.2(0.2) −1742(89)
OH 84.597 27(4) 221(9) 178 31.4 7.3(0.2) −1712(90)
OH 119.233 37(5) 253(11) 28.9 6.8(0.3) −1842(102)
OH 119.441 13(4) 236(10) 28.9 6.7(0.2) −1695(93)
18OH 84.947 8(9) 99(23) 32.6 1.8(0.4) −191(59)
18OH 85.123 −39(20) 201(48) 32.6 1.3(0.3) −273(86)
18OH 120.171 −36(33) 254(82) 29.3 0.8(0.2) −227(96)

Notes.

(a)

Values from Gaussian fits to the lines, numbers in parenthesis indicate 1σ uncertainties from these fits.

(b)

Velocity shift of line center relative to z = 0.012999.

(c)

FWHM of lines.

(d)

Inferred velocity width is based on the instrument resolution assuming a Gaussian profile; this is not listed for doublets that are not well separated.

(e)

Value of the fitted baseline at the line center.

(f)

The P-Cygni profile has been fitted using a combination of one absorption and one emission component.

(g)

The two Λ-components are (nearly) blended into a single spectral feature.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.