Table 3

Monitor and control functions implemented in the EMIR system.

Subsys Function Ch/mod Mods Type

Opt. Carousels 1 2 Step mot
Dichroics 1 1 Step mot
Ambient Temp 1 2 Temp sens

Mxrs Junction bias 4 4 D/A + A/D
Josephson coils 4 2 D/A + A/D

LO Gunn osc tuning 2 4 DC servo
Attenuators 3 4 DC servo
Harm mxr bias 1 4 D/A + A/D
PLL IF level 1 4 A/D
Gunn bias 1 1 D/A + A/D
PLL err volt 1 4 A/D
PLL loop gain 1 4 D/A + A/D

IF Bias monitor 4 4 A/D
Attenuator 4 4 4-bit I/O
IF level 4 4 A/D

Cryo Temp sensors 8 1 A/D
Vacuum gauge 1 1 A/D

Notes. Some abbreviations have been used because of width limitations. Step mot: stepper motor; Temp sens: temperature sensor; Mxrs: SIS mixers; D/A: digital to analogue converter (and conversely); Gunn osc: Gunn oscillator; DC servo: DC servomotor; Harm mxr: harmonic mixer; PLL: phase lock loop; err volt: error voltage. “Josephson coils” is shorthand for the coils that generate a magnetic field to suppress the Josephson effect in the superconducting junctions.