Open Access

Table C.1.

Line fluxes extracted over different areas.

Line λobs 2×FWHM Flux
[μm] ["] [pc] [10−17 W m−2]

Full ND ICND CH1 (a) (b)
[FeII] 26.04 1.93 35.51 7.24 ± 0.39 3.80 ± 0.31 3.43 ± 0.29 4.52 ± 0.39 0.08 ± 0.04 0.04 ± 0.04
[OIV] 25.93 1.92 35.33 101.51 ± 0.43 75.03 ± 0.42 26.48 ± 0.24 78.32 ± 0.43 1.02 ± 0.04 2.79 ± 0.04
[SI] 25.30 1.88 34.59 2.13 ± 0.29 1.50 ± 0.22 0.63 ± 0.22 1.66 ± 0.29 0.04 ± 0.03 0.00 ± 0.03
[NeV] 24.36 1.82 33.49 24.76 ± 0.34 18.98 ± 0.31 5.79 ± 0.20 20.04 ± 0.34 0.13 ± 0.03 0.34 ± 0.02
[SIII] 18.75 1.45 26.68 59.88 ± 0.50 41.64 ± 0.53 18.24 ± 0.15 43.78 ± 0.50 0.56 ± 0.02 1.08 ± 0.02
[FeII] 17.97 1.40 25.76 3.59 ± 0.20 2.88 ± 0.21 0.71 ± 0.07 3.23 ± 0.20 0.03 ± 0.01 0.07 ± 0.01
[NeIII] 15.58 1.24 22.82 156.44 ± 0.45 121.01 ± 0.69 35.43 ± 0.23 144.96 ± 0.45 1.25 ± 0.04 2.92 ± 0.04
[NeV] 14.34 1.16 21.34 25.41 ± 0.04 19.52 ± 0.04 5.89 ± 0.03 23.89 ± 0.04 0.10 ± 0.01 0.34 ± 0.01
[ClII] 14.39 1.16 21.34 0.90 ± 0.03 0.22 ± 0.03 0.68 ± 0.02 0.59 ± 0.03 0.05 ± 0.01 0.04 ± 0.01
[NeII] 12.84 1.06 19.50 283.30 ± 0.75 178.27 ± 0.77 105.03 ± 0.56 236.81 ± 0.75 4.03 ± 0.10 7.00 ± 0.13
[ArV] 13.12 1.08 19.87 1.69 ± 0.04 1.29 ± 0.05 0.40 ± 0.03 1.56 ± 0.04 0.02 ± 0.01
[SIV] 10.53 0.91 16.74 14.51 ± 0.04 7.87 ± 0.03 6.64 ± 0.03 13.55 ± 0.04 0.12 ± 0.01 0.26 ± 0.01
[FeVII] 9.54 0.84 15.46 2.27 ± 0.06 1.46 ± 0.03 0.80 ± 0.05 2.22 ± 0.06 0.00 ± 0.01 0.04 ± 0.01
[ArIII] 9.01 0.81 14.90 12.45 ± 0.16 8.68 ± 0.09 3.77 ± 0.14 12.30 ± 0.16 0.04 ± 0.04 0.16 ± 0.03
[ArV] 7.91 0.73 13.43 1.30 ± 0.04 0.82 ± 0.02 0.48 ± 0.04 1.24 ± 0.04 0.00 ± 0.01 0.01 ± 0.01
[FeVII] 7.83 0.73 13.43 1.93 ± 0.09 1.33 ± 0.05 0.60 ± 0.07 1.89 ± 0.09 0.01 ± 0.02 0.02 ± 0.02
[NeVI] 7.66 0.72 13.25 26.85 ± 0.42 18.64 ± 0.38 8.21 ± 0.21 26.71 ± 0.42 0.01 ± 0.04 0.19 ± 0.04
[NaIII] 7.33 0.70 12.88 2.38 ± 0.20 1.63 ± 0.14 0.76 ± 0.15 2.38 ± 0.20 0.12 ± 0.04 0.12 ± 0.05
[ArII] 7.00 0.67 12.33 66.71 ± 0.31 55.43 ± 0.16 11.27 ± 0.26 66.71 ± 0.31 0.03 ± 0.07 0.13 ± 0.08
[NiII] 6.65 0.65 11.96 3.63 ± 0.25 2.25 ± 0.10 1.38 ± 0.22 3.63 ± 0.25 0.01 ± 0.06 0.03 ± 0.07
[MgV] 5.62 0.58 10.67 8.17 ± 0.51 5.12 ± 0.38 3.05 ± 0.35 8.17 ± 0.51 0.00 ± 0.10 0.09 ± 0.11
[MgVII] 5.51 0.58 10.67 3.04 ± 0.10 1.54 ± 0.04 1.50 ± 0.09 3.04 ± 0.10 0.00 ± 0.03 0.00 ± 0.03
H2 0 − 0 S(1) 17.07 1.34 24.66 33.29 ± 0.02 2.18 ± 0.03 31.11 ± 0.02 17.34 ± 0.02 1.79 ± 0.01 1.89 ± 0.01
H2 0 − 0 S(2) 12.30 1.02 18.77 18.84 ± 0.03 1.04 ± 0.03 17.80 ± 0.02 11.05 ± 0.03 1.16 ± 0.01 1.14 ± 0.01
H2 0 − 0 S(3) 9.68 0.85 15.64 19.62 ± 0.04 1.04 ± 0.01 18.58 ± 0.03 16.64 ± 0.04 1.53 ± 0.01 1.51 ± 0.01
H2 0 − 0 S(4) 8.04 0.74 13.62 11.88 ± 0.04 0.76 ± 0.02 11.11 ± 0.04 10.49 ± 0.04 0.92 ± 0.01 0.88 ± 0.01
H2 0 − 0 S(5) 6.92 0.67 12.33 22.28 ± 0.05 1.88 ± 0.03 20.40 ± 0.04 22.28 ± 0.05 1.75 ± 0.01 1.68 ± 0.01
H2 0 − 0 S(6) 6.12 0.62 11.41 5.25 ± 0.06 0.47 ± 0.02 4.79 ± 0.05 5.26 ± 0.06 0.32 ± 0.01 0.35 ± 0.01
H2 0 − 0 S(7) 5.52 0.58 10.67 12.37 ± 0.08 1.44 ± 0.03 10.93 ± 0.07 12.37 ± 0.08 0.83 ± 0.02 0.76 ± 0.02
H2 0 − 0 S(8) 5.06 0.55 10.12 2.85 ± 0.08 0.29 ± 0.03 2.57 ± 0.07 2.85 ± 0.08 0.20 ± 0.02 0.18 ± 0.02
Log10 ( LH2 ) [W] 32.34 31.20 32.31 32.23 31.18 31.18
Log10 ( LX(2 − 10 keV) ) [W] 34.70 34.50 34.20

Notes. Areas : the entire FoV of the respective channel (Full), the ND within an aperture of radius 2×FWHM (the extent of which is provided in the third column in arcsec and pc), outside the ND (ICND), and the area covered by the FoV of CH1. The line fluxes are computed via spectral profile integration, with boundaries displayed in Appendix C (Figure C.2), and are aperture corrected based on the correction factors from Law et al. (2025). We also provide extractions from the Northern hotspot (a) and the Southern hotspot (b) (see Section 3.2 and Figure 3). For the [ArV] line, the noisy background makes it impossible to obtain a meaningful result in region (a). The last two lines provide respectively the logarithmic luminosities of the summed H2 lines and the X-ray luminosities obtained from Ogle et al. (2010), Kraft et al. (2002) (both in Watt).