Open Access

Table B.2

Ratios of predicted integrated line and PAH intensities to their true values.

Line (μm) Rec.? Filter(s) Region Deviation
H II Atomic DF1 DF2 DF3
NIRCam
[Fe II] 1.64 F164N 7.85 7.89 10.80 22.03 19.89 0.753
F164N-F162M 1.42 1.38 0.66 2.08 1.99 0.279
(F164N−αF162M)+β 1.08 1.00 0.61 1.86 1.91 0.285
Pa α 1.87 F187N 1.12 1.14 1.15 1.15 1.14 0.043
F187N-F182M 0.95 0.95 0.96 0.95 0.95 0.014
(F187N−αF182M)+β 1.00 1.00 1.00 1.00 0.99 0.004
H2 1-0 S(1) 2.12 F212N 14.54 20.72 6.09 2.72 2.14 0.692
F212N-F210M −5.29 −3.62 −0.29 0.30 0.36 0.591
(F212N−αF210M)+β −0.79 1.92 1.20 0.87 0.78 0.194
H2 1-0 O(5) 3.24 F323N 48.73 123.66 26.08 13.04 10.92 1.216
F323N-F300M 22.72 90.87 20.29 10.44 8.54 1.116
(F323N−αF300M)+β 31.12 101.35 22.19 11.31 9.34 1.153
PAH 3.3 F335M 1.69 1.18 1.14 1.11 1.14 0.072
F335M-F300M 0.97 0.96 0.96 0.95 0.96 0.017
(F335M–αF300M)+β 1.03 0.97 0.99 0.99 1.03 0.015
Br α 4.05 F405N 1.30 1.54 1.70 1.57 1.53 0.140
F405N-F480M 1.10 1.00 0.94 0.91 0.90 0.072
(F405N−αF480M)+β 1.15 1.09 1.09 1.07 1.08 0.040
H2 0-0 S(9) 4.69 F470N 21.71 43.30 12.26 6.66 4.92 0.954
F470N-F480M −1.06 −1.56 0.55 0.76 0.71 0.353
(F470N−αF480M)+β 0.36 0.78 1.23 1.15 1.01 0.229
MIRI
PAH 7.7 μm F770W 2.94 1.90 1.87 2.11 2.31 0.234
F770W-F1000W −0.63 0.94 0.94 0.75 0.61 0.251
(F770W−αF1000W)+β −0.34 0.97 1.04 0.93 0.98 0.157
PAH 11.2 μm F1130W 2.91 1.58 1.67 1.93 2.20 0.213
F1130W-F1000W 1.29 1.05 1.09 1.15 1.17 0.045
(F1130W−αF1000W)+β 1.10 1.01 1.01 1.04 0.98 0.015
F1130W-F1500W −2.29 −0.31 −0.28 −0.63 −0.98 1.531
F1130W–αF1500W+β 1.18 0.98 1.02 1.05 1.05 0.021
(F1130W–α1F1000W–α2F1500W) + β(a) 1.10 1.01 1.01 1.04 0.98 0.015

Notes. Best-fit values of α and β for each filter combination (Eq. 5) are shown in Table 4. Negative ratios indicate that the prescription gives a negative intensity by over-correcting the continuum. The “Deviation” column shows the mean deviation (in dex) from the 1:1 relation (the expected relation) between the actual line intensity and the calculated combination of the filters derived from all the data shown in scatter plots (Fig. 4 and Figs. C.1C.8). Rows with a checkmark (✓) in the “Rec.?” column indicate our recommended prescriptions for tracing line or PAH emission. (a)α1 = 0.98, α2 = 0.01, β = −3.6 × 102 MJy sr−1.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.