Euclid on Sky
Open Access

Table 3

NI-CU FM key parameters.

Mass 607 g
Length 155 mm
Max. diameter 104 mm
Top baffle diameter 55 mm
Harness lengths 680 mm
Power consumption at 135 K ≤110 mW

Max drive current I 100 mA
Min drive current I , full stability 10 mA
Min drive current I , reduced stability 1 mA
Min/max PWM duty cycle 5–50%
Drift over 1200 s, channels A, B, C, E (for drive current 10–100 mA) ≤0.2%
RMS over 1200 s w/o drift, all channels ≤0.1%
Stabilisation time ≲20s
Spatial homogeneity, RMS ≲0.15%

Notes. The temporal drift is bound by the drift of the driving power supply in NISP’s ICU. Its rating is 0.1% stability at 10 mA, proportionally decreasing below this.