Table 3.

Best-fit free parameters for the RGS data fitting.

Component Parameter Value
HOTMW-cold NH [cm−2] (1.98 ± 0.05)×1020
T [keV] 1.0 × 10−6 [fixed]

POW norm (3.27 ± 0.02)×1051
[photons s−1 keV−1]
Γ1 2.80 ± 0.01
Γ2 2.51 ± 0.05
Ebreak [keV] 0.99 ± 0.03

HOTMW-warm NH [cm−2] (1.0 ± 0.3)×1019
T [keV] (5.00 ± 1.40)×10−2

AMOLdust Ndust [cm−2] (7.29 ± 0.93)×1016
vout [km s−1] 270 ± 110

XABSWA1 NH [cm−2] (1.20 ± 0.19)×1021
log ξ [erg cm s−1] 2.15 ± 0.05
CV(a) 0.85 ± 0.09
vout [km s−1] 60 ± 40

XABSWA2 NH [cm−2] (1.64 ± 0.56)×1020
log ξ [erg cm s−1] −0.58 ±0.11
CV(a) ≤1
vout [km s−1] ≤110

HOTCIA NH [cm−2] (8.17 ± 0.32)×1021
T [keV] (5.07 ± 0.31)×10−2
CV(a) 0.47 ± 0.08
vout [km s−1] 250 ± 70

PIONem NH [cm−2] (9.00 ± 0.61)×1022
log ξ [erg cm s−1] 1.56 ± 0.05
Ω/4π(b) (3.84 ± 1.31)×10−3
vout [km s−1] ≤40

Notes.

(a)

Unit-less parameter representing the covering factor of the absorber.

(b)

Aperture angle for emission. Although called Ω in SPEX, it is meant to represent Ω/4π.