Open Access

Table 1.

Observed bands, values used throughout the data calibration, and peak Stokes I and linear polarization intensities.

Band νc Range bmaj bmin bPA Gc σdterms EVPAVLA σEVPA Peak I σI Peak P σP
name [GHz] [GHz] [mas] [mas] [°] [°] [°] [ mJy beam ] $ \left[{\frac{\mathrm{mJy}}{\mathrm{beam}}}\right] $ [ mJy beam ] $ \left[{\frac{\mathrm{mJy}}{\mathrm{beam}}}\right] $ [ mJy beam ] $ \left[{\frac{\mathrm{mJy}}{\mathrm{beam}}}\right] $ [ mJy beam ] $ \left[{\frac{\mathrm{mJy}}{\mathrm{beam}}}\right] $
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14)
12 GHz 12.168 11.912 − 12.424 0.69 0.45 −38 1.03 0.031 −28.64 3.38 5458 2 57 4
15 GHz 15.368 15.112 − 15.624 0.74 0.51 −23 1.09 0.021 −36.07 1.15 7056 5 106 8
24 GHz 23.568 23.312 − 23.824 0.53 0.35 −22 1.25 0.031 −40.63 1.19 9641 13 225 15
43 GHz 43.169 42.913 − 43.425 0.21 0.11 −40 1.60 0.016 −42.02 1.73 9550 8 181 7

Notes. Columns descriptions: (column 1) the band name used in the text, (column 2) the observed central frequency, (column 3) range of observed frequencies, (column 4) the major axis of the nominal beam at each frequency, (column 5) the minor axis of the nominal beam, (column 6) the position angle of the nominal beam, (column 7) the gain corrections discussed in Sect. 2.1, (column 8) scatter of D-terms, (column 9) absolute EVPA correction from VLA observations at νc, (column 10) scatter of the model of EVPA, (column 11) the peak Stokes I, (column 12) the noise in Stokes I based on the rms of the map, (column 13) the peak linear polarization, and (column 14) the noise in linear polarization calculated using the method outlined in Sect. 2.2.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.