Simulation settings used in LIFESIM.

Parameter LIFESIM
Interferometric Baseline (m) 14.5
Aperture Diameter (m) 2
Wavelength (μm) 4.0–18.5
Spectral Resolution 50
Reference S/N (a) 10
Reference Wavelength (μm) (a) 11.2
Detector quantum efficiency 0.7
Total instrument throughput 0.05

Notes. See LIFE Paper I and LIFE Paper II for details. (a)The S/N is initially calculated for a set exposure time (1 hr), then scaled to the reference S/N value at the reference wavelength.