Table 2.
EW (in eV) of Fe XXVI Lyα1 and Fe XXVI Lyα2 estimated for different magnetisations from the model spectra (Sect. 5.1.3) and by fitting fake-spectra with multiple narrow width restricted Gaussians (Sect. 6.2).
μ | Lyα1 | Lyα2 | Lyα1/Lyα2 | |||
---|---|---|---|---|---|---|
Model spectra | Fake-spectra | Model spectra | Fake-spectra | Model spectra | Fake-spectra | |
0.0010 | 19.5 | 22.5 (14.1–32.3) | 7.7 | 2.6 (1.7–3.8) | 2.5 | 8.7 |
0.0029 | 16.6 | 21.1 (13.3–29.3) | 5.6 | 3.1 (1.5–4.6) | 3.0 | 6.8 |
0.0059 | 12.1 | 14.3 (9.3–18.9) | 6.0 | 3.8 (2.2–4.9) | 2.0 | 3.8 |
0.0160 | 9.8 | 12.3 (9.0–15.1) | 6.1 | 3.5 (3.1–3.9) | 1.6 | 3.5 |
0.0674 | 9.9 | 13.3 (5.3–21.4) | 6.7 | 4.4 (3.2–5.7) | 1.5 | 3.0 |
Notes. For the fake-spectra listings, 90% confidence range is presented in the brackets. The ratio of the two lines is presented in last two columns.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.