Table B.1
Upper limits of non-detections.
Name | Molecular formula | Upper limit (cm−2) |
---|---|---|
Methanol | CH318OH | <5.0 ×l017 |
Formamide | NH2CDO | <2.0 ×l015 |
Formamide | NH132CHO | <1.2 ×l016 |
Formamide | cis-NHDCHO | <2.5 ×1015 |
Formamide | trans-NHDCHO | <5.0 ×l015 |
Formamide | NH2CHO(υ12 = 1) | <5.0 ×1017 |
Z-cyanomethanimine | Z-HNCHCN | <5.5 ×1015 |
Methanethiol | 13CH3SH | <7.0 ×1015 |
Cyanodiacetylene | HC5N | <2.0 ×l013 |
Ethylene oxide | c-CD2CH2O | <6.0 ×1014 |
Acetaldehyde | CH133CHO | <6.0 ×l015 |
Vinyl cyanide | C2H3CN | <4.0 ×1015 |
Glycolaldehyde | CH2OHCDO | <1.0 ×l015 |
Glycolaldehyde | CH2ODCHO | <5.0 ×1014 |
Glycolaldehyde | CH2OH13CHO | <1.5 ×l015 |
Methyl formate | CH3O13CHO | <7.0 ×1015 |
Propargyl cyanide | HCCCH2CN | <7.0 ×1014 |
Propenal | C2H3CHO | <1.5 ×l014 |
Protonated cyanodiacetylene | HC5NH+ | <1.5 ×1013 |
Urea | H2NCONH2 | <1.5 ×l014 |
Ethanol | a-13CH3CH2OH | <8.0 ×1014 |
Ethanol | a-CH133CH2OH | <1.5 ×l018 |
Ethanol | a-CH3CH2OD | <1.0 ×l015 |
Ethanol | a-s-CH2DCH2OH | <3.0 ×l015 |
Gauche-ethyl mercaptan | g-C2H5SH | <1.0 ×l015 |
Methoxymethanol | CH3OCH2OH | <4.0 ×1017 |
s-propanal | s-C2H5CHO | <1.5 ×l015 |
g-propanal | g-C2H5CHO | <3.5 ×1017 |
Cyclopentadiene | c-C5H6 | <5.0 ×1016 |
Ethanolamine | NH2CH2CH2OH | <6.0 ×1014 |
Ga-n-propanol | Ga-n-C3H7OH | <6.0 ×1015 |
Glyceraldehyde | HCOCHOHCH2OH | <8.0 ×l015 |
g-Isopropanol | g-i-C3H7OH | <1.5 ×l016 |
a-Isopropanol | a-i-C3H7OH | <2.0 ×1016 |
Benzonitrile | c-C6H5CN | <1.0 ×l014 |
Benzaldehyde | c-C6H5CHO | <7.0 ×1014 |
GGag′g′-Glycerol | GGag′g′-HOCH2CH(OH)CH2OH | <8.0 ×1014 |
G′Gg′gg′-Glycerol | G′Gg′gg′-HOCF2CF(OH)CH2OH | <7.0 ×1015 |
Indene | c-C9H8 | <1.0 ×l016 |
1-cyanonaphthalene | 1-C10H7CN | <1.0 ×1014 |
2-cyanonaphthalene | 2-C10H7CN | <2.0 ×1014 |
Notes. Upper limits on column densities toward the 0.5″offset position from source B in a ~1″ beam. If a source size of 0.5″ was assumed, these values would increase by a factor of ~5. The upper limits are measured by fixing Tex to 100 K and FWHM to 2 km s−1. Vibrational correction factors are not included in these values.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.