Open Access

Table 3.

Best-fitting model parameters of the fits to the NuSTAR and NuSTAR+IXPE data.

Parameter NuSTAR NuSTAR+IXPE
diskbb
kTin (keV) 1.00  ±  0.04 1.020  ±  0.005
Nd 190  ±  25 168  ±  5

comptb
kTs (keV) 1.59  ±  0.07 1.575  ±  0.005
α 2.5  ±  0.3 [2.5]
kTe (keV) 3.4  ±  0.3 [3.4]
Nc (10−2) 3.7  ±  0.1 3.77  ±  0.03

relxillns
qem [3] [3]
a [0.2] [0.2]
incl (deg) 28  ±  8 [28]
Rin (units of RISCO) 5  ±  3 [5]
kTbb (keV) =1.59 =1.575
log(ξ/erg cm s−1) 3.3  ±  0.3 [3.3]
AFe [1] [1]
log ne [18] [18]
Nr (10−4) 4  ±  1 3.3  ±  0.3

Cross-calibration
numliv1 0.94  ±  0.01 [0.94]
CFPMB − FPMA 1.006  ±  0.001 [1.006]
CDU1 − FPMA 0.907  ±  0.005
CDU2 − FPMA 0.877  ±  0.005
CDU3 − FPMA 0.827  ±  0.004
Gain shift
αDU1
βDU1 (eV)
αDU2 0.987  ±  0.002
βDU2 (eV) −16  ±  8
αDU1
βDU1 (eV)

χ2/d.o.f. 229/224 865/841

Photon flux ratios(a)
2–8 keV
Fdiskbb/Ftot 0.51
Fcomptb/Ftot 0.43
Frelxillns/Ftot 0.06
2–4 keV
Fdiskbb/Ftot 0.66
Fcomptb/Ftot 0.30
Frelxillns/Ftot 0.04
4–8 keV
Fdiskbb/Ftot 0.26
Fcomptb/Ftot 0.66
Frelxillns/Ftot 0.08
Energy flux (2–8 keV)
Ftot (erg cm−2 s−1) 4.1 × 10−9

Notes. Uncertainties are given at the 68% confidence level for one parameter of interest. Parameters in square bracket were kept frozen during the fit.

(a)

The photon fluxes are in units of photon cm−2 s−1.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.