Table 4.
Average values and standard deviations of the imaging parameters estimated by VIS_FWDFIT and VIS_FWDFIT_PSO for the reconstruction of the six synthetic configurations in the first row of Figs. 4 and 5.
First source |
Second source |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flux | FWHM | x | y | Flux | FWHM | x | y | |||
(counts s−1 keV−1 cm−2) | (arcsec) | (arcsec) | (arcsec) | (counts s−1 keV−1 cm−2) | (arcsec) | (arcsec) | (arcsec) | |||
Simulated | 5000.0 | 8.0 | 0.0 | 0.0 | 5000.0 | 8.0 | 30.0 | 30.0 | ||
C1 | VIS_FWDFIT | 4900 ± 500 | 8.0 ± 2.0 | −1.0 ± 0.4 | −0.2 ± 0.6 | 5100 ± 500 | 20.0 ± 10.0 | 35.0 ± 5.0 | 35.0 ± 5.0 | |
VIS_FWDFIT_PSO | 4780 ± 90 | 8.5 ± 0.7 | −0.1 ± 0.2 | 0.1 ± 0.2 | 4840 ± 60 | 8.7 ± 0.4 | 30.1 ± 0.2 | 30.1 ± 0.2 | ||
Simulated | 5000.0 | 8.0 | −15.0 | −15.0 | 3000.0 | 8.0 | 15.0 | 15.0 | ||
C2 | VIS_FWDFIT | 4000 ± 3000 | 40.0 ± 10.0 | −5.0 ± 3.0 | −5.0 ± 3.0 | 4000 ± 2000 | 40.0 ± 10.0 | −2.0 ± 5.0 | −1.0 ± 5.0 | |
VIS_FWDFIT_PSO | 4880 ± 80 | 8.4 ± 0.6 | −14.9 ± 0.2 | −15.0 ± 0.2 | 2840 ± 90 | 8.3 ± 0.9 | 14.9 ± 0.5 | 14.9 ± 0.4 | ||
Simulated | 5000.0 | 8.0 | −15.0 | 0.0 | 5000.0 | 8.0 | 15.0 | 0.0 | ||
C3 | VIS_FWDFIT | 5100 ± 300 | 10.0 ± 1.0 | −14.9 ± 0.4 | −0.1 ± 0.4 | 4700 ± 200 | 12.0 ± 4.0 | 18.0 ± 4.0 | 0.1 ± 0.3 | |
VIS_FWDFIT_PSO | 4800 ± 200 | 8.5 ± 0.6 | −15.1 ± 0.2 | 0.1 ± 0.3 | 4800 ± 100 | 8.4 ± 0.6 | 15.0 ± 0.3 | −0.1 ± 0.2 | ||
Loop | ||||||||||
Flux | FWHM max | FWHM min | α | x | y | Loop angle | ||||
(counts s−1 keV−1 cm−2) | (arcsec) | (arcsec) | (deg) | (arcsec) | (arcsec) | (deg) | ||||
C4 | Ground truth | 80 000.0 | 22.5 | 9.0 | 0.0 | 20.0 | 0.0 | 70.0 | ||
VIS_FWDFIT | 78300 ± 200 | 24.5 ± 0.9 | 10.0 ± 0.7 | 0.1 ± 0.6 | 20.0 ± 0.2 | 0.0 ± 0.3 | 69.0 ± 2.0 | |||
VIS_FWDFIT_PSO | 78300 ± 200 | 24.5 ± 0.9 | 10.0 ± 0.7 | 0.1 ± 0.6 | 20.0 ± 0.2 | 0.0 ± 0.3 | 69.0 ± 2.0 | |||
C5 | Ground truth | 80 000.0 | 22.0 | 14.0 | 45.0 | 20.0 | 20.0 | 105.0 | ||
VIS_FWDFIT | 78 400 ± 200 | 19.1 ± 0.3 | 12.3 ± 0.2 | 44.0 ± 1.0 | 20.1 ± 0.1 | 20.0 ± 0.1 | 101.0 ± 7.0 | |||
VIS_FWDFIT_PSO | 78 400 ± 200 | 19.1 ± 0.3 | 12.3 ± 0.2 | 44.0 ± 1.0 | 20.1 ± 0.1 | 20.0 ± 0.1 | 101.0 ± 7.0 | |||
C6 | Ground truth | 9000.0 | 22.0 | 12.0 | 45.0 | 15.0 | 15.0 | 105.0 | ||
VIS_FWDFIT | 8800 ± 100 | 20.8 ± 0.6 | 11.0 ± 2.0 | 45.0 ± 2.0 | 15.1 ± 0.2 | 15.0 ± 0.2 | 106.0 ± 6.0 | |||
VIS_FWDFIT_PSO | 8800 ± 100 | 21.1 ± 0.6 | 11.5 ± 0.5 | 45.0 ± 2.0 | 15.2 ± 0.2 | 15.0 ± 0.2 | 105.0 ± 6.0 |
Notes. For each configuration, the two algorithms have been applied to 25 random realizations of the STIX synthetic visibilities.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.