Table 1.
ON/OFF analysis (input and output parameters) for the FOXSI-2 observations.
D101 | D104 | D105 | D108 | All four Det | |
---|---|---|---|---|---|
NON (ΔtON = 68.5 s) | 13 | 9 | 10 | 10 | 36 |
NOFF (ΔtOFF = 24.2 s) | 3 | 1 | 1 | 4 | 9 |
α | 0.920 | 0.872 | 0.869 | 0.859 | 0.887 |
P(H0|NON, NOFF, α) | 8.3 × 10−3 | 5.5 × 10−3 | 2.8 × 10−3 | 6.2 × 10−2 | 1.2 × 10−5 |
Sb | 2.64 | 2.78 | 2.99 | 1.86 | 4.4 |
λ2σ | 19.09 | 15.52 | 16.83 | 14.73 | 10.5 |
Notes. Input (first three rows) and output (last three rows) parameters of the ON/OFF Li-Ma analysis applied to four of the FOXSI-2 silicon detectors (first four columns). The rightmost column has the ON/OFF Li-Ma parameters for the case in which we combine the data of all four detectors. NON are the counts recorded during the ON configuration of target I/FOXSI-2 observations (green area of Fig. 3). NOFF are the counts for the background observations. α is estimated following Eq. (4) (for individual detectors) and Eq. (7) (for the case of all four detectors combined). P(H0|NON, NOFF) are the probabilities that the null hypothesis (H0) is true given the particular values of NON, NOFF, and α. Sb is the Bayesian significance for the existence of a hypothetical signal s on top of the background during the ON-configured observations. λ2σ is the upper limit (in counts) with a 2σ precision for the flux of such a hypothetical source s.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.