Table 3
Summary of the Euclid NISP AB mag photometric system.
NISP spectral response characteristics | ||||||||
---|---|---|---|---|---|---|---|---|
Filter | 0.1% cut-on (nm) | 50% cut-on (nm) | 50% cut-off (nm) | 0.1% cut-off (nm) | λcen (nm) | Width (nm) | 〈Tpeak〈 | ZP (AB mag) |
Filter | 0.1% cut-on (nm) | 50% cut-on (nm) | 50% cut-off (nm) | 0.1% cut-off (nm) | λcen (nm) | Width (nm) | 〈Tpeak〈 | ZP (AB mag) |
YE | 937.5 | 949.6 | 1212.3 | 1243.2 | 1080.9 | 262.7 | 0.772 | 25.04 |
JE | 1151.1 | 1167.6 | 1567.0 | 1595.0 | 1367.3 | 399.4 | 0.790 | 25.26 |
HE | 1495.6 | 1521.5 | 2021.4 | 2056.8 | 1771.4 | 499.9 | 0.782 | 25.21 |
Wavelength uncertainty (centre of FPA) | Wavelength uncertainty (corner of FPA) | |||||||
Filter | σ50 (nm) | σcen (nm) | σ50 (nm) | σcen (nm) | ||||
YE | 0.8 | 0.6 | 0.8 | 0.6 | ||||
JE | 0.8 | 0.6 | 0.9 | 0.6 | ||||
HE | 0.8 | 0.6 | 0.9 | 0.6 |
Notes. Wavelengths and their uncertainties are computed from higher precision data and rounded to one digit. The first half of the table lists the global passband characteristics; ‘width’ refers to the distance between the 50% cut-on and cut-off wavelengths, 〈Tpeak〉 to the mean in-band response, and ZP to the photometric zero point in the AB system. The second half of the table lists the total uncertainties of the cut-on and cut-off wavelengths, σ50, and that of the central wavelength, σcen.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.