Table 3.
Analysis of 47 Tuc.
This analysis |
L2017 (1) | MB2008 (2) | KM2008 (3) | S2013 (4) | T2014 (5) | |||||
---|---|---|---|---|---|---|---|---|---|---|
DSEP LTE | DSEP | BaSTI | ||||||||
α = 0 | α = −1 | Kroupa | NLTE α = −1 | |||||||
[Fe/H] | −0.763 | −0.748 | −0.726 | −0.735 | −0.724 | −0.863 | −0.75 | −0.76 | −0.81 ± 0.02 | −0.78 ± 0.07 |
[Na/Fe] | +0.417 | +0.393 | +0.357 | +0.237 | +0.237 | +0.422 | +0.45 | +0.21 | +0.38 ± 0.12 | +0.21 ± 0.14 |
[Mg/Fe] | +0.432 | +0.404 | +0.359 | +0.404 | +0.392 | +0.442 | +0.22 | +0.46 | +0.42 ± 0.14 | +0.44 ± 0.08 |
[Si/Fe] | +0.392 | +0.389 | +0.393 | (+0.376) | (+0.368) | … | +0.37 | +0.39 | … | +0.32 ± 0.09 |
[Ca/Fe] | +0.325 | +0.296 | +0.237 | +0.238 | +0.239 | +0.412 | +0.31 | +0.34 | … | +0.24 ± 0.13 |
[Ti/Fe] | +0.330 | +0.337 | +0.341 | +0.412 | +0.421 | +0.370 | +0.41 | +0.37 | … | +0.37 ± 0.11 |
[Sc/Fe] | +0.189 | +0.209 | +0.248 | (+0.197) | (+0.207) | +0.219 | +0.14 | … | … | +0.11 ± 0.11 |
[Cr/Fe] | −0.016 | −0.017 | −0.019 | (−0.029) | (−0.036) | −0.060 | −0.02 | … | … | −0.03 ± 0.11 |
[Mn/Fe] | −0.262 | −0.256 | −0.249 | −0.188 | −0.205 | −0.229 | −0.44 | … | … | −0.20 ± 0.13 |
[Ni/Fe] | +0.020 | +0.028 | +0.045 | +0.060 | +0.068 | … | +0.00 | … | −0.12 ± 0.04 | |
[Cu/Fe] | −0.046 | −0.036 | −0.021 | (−0.049) | (−0.028) | … | −0.13 | … | … | −0.14 ± 0.35 |
[Zn/Fe] | +0.120 | +0.126 | +0.143 | (+0.113) | (+0.165) | … | … | … | … | +0.26 ± 0.13 |
[Zr/Fe] | +0.208 | +0.237 | +0.288 | (+0.224) | (+0.165) | … | +0.05 | … | … | +0.41 ± 0.17 |
[Ba/Fe] | +0.192 | +0.205 | +0.230 | +0.133 | +0.159 | +0.155 | +0.02 | … | … | +0.25 ± 0.24 |
[Eu/Fe] | +0.262 | +0.238 | +0.232 | (+0.225) | (+0.258) | … | +0.04 | … | +0.27 ± 0.14 | +0.32 ± 0.19 |
Notes. The NLTE columns give the abundance ratios, corrected for NLTE effects, for DSEP and BaSTI isochrones and a MF slope of α = −1. For values in parentheses, no explicit NLTE corrections were computed and the NLTE values only differ from the LTE values because of the 0.012 dex change in the iron abundance.
References. (1) Larsen et al. (2017); (2) McWilliam & Bernstein (2008); (3) Koch & McWilliam (2008); (4) Sakari et al. (2013): [Fe/H] is [Fe I/H]; (5) Thygesen et al. (2014): abundances are median and uncertainty on median, except [Fe/H] for which the mean value is given.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.