Free Access

Table A.1

Overview of sensitivity tests performed with the impact on the computed OLR value. The Original param. column indicates the parametrisation used in the considered model, and the Tested param. column shows the tested parametrisation. The OLR difference between original and modified parametrisations is indicated in the OLR difference column.

Model tested Original param. Tested param. OLR difference
PyRADS-Conv1D Lorentz shape Voigt shape < 1 W.m2
PyRADS-Conv1D & Exo_k with foreign broad. without foreign broad. up to 20 W.m2
PyRADS-Conv1D MT_CKD3.2 [0.1 - 10k]cm−1 MT_CKD3.2 [0.1 - 20k]cm−1 < 2 W.m2
Exo_k MT_CKD3.2 MT_CKD2.5 < 2W.m2
Exo_k with H2O-N2 cont. without H2O-N2 cont. up to 12 W.m2 (at low T)
Exo_k with N2-N2 cont. without N2-N2 cont. up to 4 W.m2 (at low T)
PyRADS-Conv1D without water iso. with water iso. < 2 W.m2
kcm1d & Exo_k without CO2 376ppm of CO2 up to 40 W.m2
Exo_k two-stream: =0.6 two-stream: Hemis. mean ~ 6 W.m2
PyRADS-Conv1D Conv_K88 Conv_D16 < 5 W.m2

PyRADS-Conv1D high res. vertical grid low res. vertical grid up to 10 W.m2
PyRADS-Conv1D spec. res. 10−2 cm−1 spec. res. 10−3 cm−1 < 1 W.m2
Exo_k Exo_k interp. scheme kcm1d interp. scheme ~ 3 W.m2