Free Access
Table 2.
Optical system parameters of the SPICE instrument.
Parameter | Value |
---|---|
Telescope | |
Entrance aperture size | 43.5 mm × 43.5 mm |
Distance entrance aperture to mirror | 770.8 mm |
Focal length of parent paraboloid | 622 mm |
f-number | 14.30 |
Plate scale at slit | 3.02 μm/″ |
Instantaneous FOV | Slit length: 11′, plus ±0.5′ “dumbbell” apertures, oriented solar north-south |
Width, rastered FOV | 16′ |
Slits | Widths: 2″, 4″, 6″, and 30″ |
Spectrometer | |
Wavelength range, SW | 70.387–79.019 nm (1st order) |
Wavelength range, LW | 97.254–104.925 nm (1st order) |
48–53 nm (2nd order) | |
Slit to grating distance | 128 mm |
Grating groove density and ± chirp | 2400 ± 1.7% mm−1 |
Grating image distance, SW mid-band | 692.43 mm |
Grating image distance, LW mid-band | 720 mm |
Spectrometer magnification (image-distance/slit-distance) | ~5.5 |
Grating ruling period d | 1/2400 mm |
Grating angle of incidence | −1.7584° |
Grating angle of diffraction (at SW, LW) | +8.5498° at 74.7 nm +12.2398° at 101.12 nm |
Dispersion, at image plane | 0.0095 at 74 nm 0.0083 at 101 nm (per pixel spacing) |
Detector | |
Pixel spacing | 0.018 mm |
Angle of incidence on detector (SW, LW) | 27.33° at 74.7 nm, 35.33° at 101.12 nm |
System focal length (SW) | 3.371 m |
System spatial plate scale | 1.101″ px−1 at 74 nm, 1.059″ px−1 at 101 nm |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.