Free Access

Table 2.

Proposed key technical requirements for the cryogenic LNAs.

Specification Value Unit
Bandwidth 67−116 GHz
Noise temperature (67−90 GHz) <23 K
Noise temperature (90−116 GHz) <30 K
Input reflection <−6 dB
Output reflection <−10 dB
Gain >40 dB
1 dB output compression point >−10 dBm
DC power dissipation <35 mW
Nominal operating temperature 15 K