Open Access

Table 2.

Parameters for magnetized simulations.

Label tff/tact tff/tsct n0 β A lmax Resolution (AU)
T10M0+ 0 0.05 6.0 × 107 inf inf 15 2
M01 0.1 0.05 0.5 11 14 4
M04 0.4 0.05 0.03 2.75 14 4
M08 0.8 0.05 0.008 1.375 14 4
M12 1.2 0.05 0.003 0.92 14 4

T10M0A+ 0 0.15 8.2 × 104 inf inf 15 8
M04A 0.4 0.15 0.03 2.75 14 17

Notes. The label of the run, the ratio of free-fall time to Alfvén crossing time, ratio of free-fall time to sound-crossing time, central density, the plasma β, Alfvénic Mach number, maximal level of refinement, and physical resolution are listed.