Free Access

Table 9.

Results of the LFI+HFI retrieval, based on 2013 fsbeams.

Element Change
LFI FPU

Cross-scan offset...
In-scan offset......
x translation...... −0.06 mm
y translation...... −0.01 mm
z translation...... +0.05 mm
Rotation.........
p − p(x)......... 0.35 mm
p − p(y)......... 0.27 mm

HFI FPU

Cross-scan offset...
In-scan offset......
x translation...... +0.27 mm
y translation...... −0.11 mm
z translation...... +0.26 mm
Rotation.........
p − p(x)......... 0.20 mm
p − p(y)......... 0.26 mm

Primary

z translation...... 0.0 mm
Rotation......... 0°
Zernike mode (m, n)
(0, 2)......... +0.08 mm, 0°
(1, 1)......... +0.99 mm, +68°
(2, 2)......... +0.13 mm, +79°
(3, 3)......... +0.09 mm, −6°
(1, 3)......... +0.06 mm, −58°

Secondary

z translation...... 0.0 mm
Rotation......... 0°
Zernike mode (m, n)
(0, 2)......... !0.0* mm, 0°
(1, 1)......... +1.37 mm, −35°
(2, 2)......... +0.05 mm, −69°
(1, 3)......... +0.29 mm, −7°
(3, 3)......... +0.03 mm, +4°

Notes.

(a)

p − p(x) = largest remaining displacement differences in the x-direction between retrieved model and measured detector locations in the focal plane.

(b)

Zernike mode (0, 2) = defocus; (1, 1) = tilt; (2, 2) = ellipticity.