Free Access

Table 1.

Summary of continuum and [CII] line emission properties of J1015+0020 and the additional sources detected in the ALMA map.

(1) Source J1015+0020 Cont1 Cont2 CompA CompB CompC
Continuum emission
(2) f [μJy] 595 ± 64 1252 ± 76 388 ± 61 <120 <120 <125
(3) amax [″] 0.16 ± 0.03 0.19 ± 0.02 0.28 ± 0.06
(4) amin [″] 0.94 ± 0.03 0.10 ± 0.03 0.08 ± 0.06

[CII] emission
(5) f [Jy km s−1] 0.47 ± 0.05 <0.15 <0.15 0.19 ± 0.03 0.35 ± 0.06 1.13 ± 0.16
(6) amaj [″] 0.17 ± 0.03 0.28 ± 0.05 0.59 ± 0.19
(7) amin [″] 0.09 ± 0.03 0.16 ± 0.04 0.19 ± 0.04
(8) FWHM [km s−1] 339 ± 38 60 ± 13 480 ± 45 409 ± 42
(9) L[CII] [108 L] 2.9 ± 0.3 <0.92 <0.92 1.2 ± 0.1 2.2 ± 0.4 7.0 ± 1.0
(10) Angular sep [″] 3.5 3.5 0.33 1.2 2.4

Notes. Rows give the following information: (1) source ID, (2) continuum flux, (3)–(4) major and minor deconvolved axes of the continuum emission, (5) integrated [CII] flux density, (6)–(7) major and minor deconvolved axes of the [CII] emission, (8) FWHM of the [CII] line profile, (9) [CII] luminosity, and (10) angular separation from J1015+0020. For [CII]-only detected sources, i.e. CompA, CompB, and CompC, 3σ upper limits on the continuum flux are given. For continuum-only detected sources, i.e. Cont1 and Cont2, we report 3σ upper limits on the integrated [CII] flux density, computed assuming a line width of 300 km s−1 and taking into account the differential sensitivity within the FOV.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.