Free Access

Table A.1

Integrated flux density measurements for 3C 468.1 from the literature, along with the flux density scale used in the original reference, and the “correction” factor required to bring the measurement onto the SH12 scale.

Frequency Sint Flux scale Factor Catalogue reference
[MHz] [Jy]

10 700 0.31 ± 0.02 KPW KPT
5000 0.87 ± 0.04 a KPW KPW
4850 0.96 ± 0.09 B77 1.007 GC91
2695 1.93 ± 0.10 a KPW KPW
1420 5.78 ± 0.17 B77 0.972 K06
1400 5.00 ± 0.25 a KPW KPW
1400 4.95 ± 0.15 B77 0.972 C98
1400 4.89 ± 0.24 B77 0.972 WB91
1400 5.16 ± 0.13 K64 1.009 PWH
750 9.70 ± 0.49 a KPW KPW
750 10.06 ± 0.15 K64 1.012 PWH
408 21.50 ± 0.64 B77/RCB K06
365 22.13 ± 0.51 TXSc 0.977 D96
325 26.80 ± 1.34 WENSSd 0.90 R97
232 43.98 RCB Z97
178 30.00 ± 3.00 b KPW 1.09 KPW
178 30.50 ± 2.40 e CKL 1.15f G67
159 34.00 ± 3.40 g RCB B62
74 40.70 ± 0.66 B77 1.1 K07
74 42.09 ± 4.41 B77 1.1 C07
38 24.60 ± 2.46 b RCB H95

Notes.

(a)

The uncertainty is quoted as 5 per cent of the integrated flux density.

(b)

The uncertainty is quoted as 10 per cent of the integrated flux density.

(c)

Sources in the Texas radio survey were found to have flux densities that were consistent with a factor 0.9607× B77. See Douglas et al. (1996).

(d)

The WENSS flux scale is complex. An overall correction factor of 0.9 was applied to bring the flux density onto the B77 scale, then to the RCB73 scale. See Scaife & Heald (2012) for details.

(e)

The uncertainty is quoted as 8 per cent of the integrated flux density.

(f)

This conversion factor was derived using the factors in Table 7 of B77 to convert to the KPW scale and then onto SH12.

(g)

An uncertainty of 10 per cent has been assumed.

Reference. B62: Bennett (1962); B77: Baars et al. (1977); C07: Cohen et al. (2007); C98: Condon et al. (1998); CKL: Conway et al. (1963); D96: Douglas et al. (1996); G67: Gower et al. (1967); GC91: Gregory & Condon (1991); H95: Hales et al. (1995); K06: Kerton (2006); K07: Kassim et al. (2007); K64: Kellermann (1964); KPT: Kellermann & Pauliny-Toth (1973); KPW: Kellermann et al. (1969); PWH: Pauliny-Toth et al. (1966); R97: Rengelink et al. (1997); RCB: Roger et al. (1973); SH12: Scaife & Heald (2012); WB91: White & Becker (1992); Z97: Zhang et al. (1997).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.