Table B.1
Unidentified features and, in some cases, tentative line identification.
νrest | Tentative assignment | ![]() |
v exp |
(MHz) | − | (K km s-1) | (km s-1) |
|
|||
81 166 | – | 0.08 (0.03) | 16 (7) |
83 825 | SiO v = 5 J = 2–1 | 0.30 (0.03) | 35 (5) |
84 478 | – | 0.06 (0.02) | 7 (7) |
86 190 | OH v = 1 J,Ω,p,F = 8/2,3/2,1,9–8/2,3/2,−1,9 | 0.71 (0.02) | 7 (3) |
87 385 | – | 0.23 (0.02) | 17 (3) |
108 892 | – | 0.09 (0.01) | 11 (4) |
128 883 | TiO2JK,k=1910,10–209,11 | 0.10 (0.02) | 13 (4) |
131 195 | SiN N,J,F = 3,7/2,7/2-2,5/2,7/2 | 0.05 (0.01) | 7 (4) |
136 946 | – | 0.15 (0.01) | 27 (4) |
139 065 | – | 0.05 (0.01) | 13 (4) |
143 997 | – | 0.05 (0.01) | 7 (4) |
145 101 | N17O J = 3/2–1/2 hfs blend | 0.11 (0.02) | 18 (4) |
149 968 | – | 0.12 (0.02) | 18 (4) |
150 165 | – | 0.13 (0.03) | 20 (4) |
158 409 | 29Si18O J = 4–3 | 0.04 (0.01) | 10 (4) |
159 227 | 29SiS v = 1J = 9–8 | 0.08 (0.01) | 13 (4) |
159 607 | – | 0.08 (0.01) | 4 (3) |
161 197 | – | 0.06 (0.02) | 8 (4) |
165 641 | Na37Cl J = 13–12 | 0.09 (0.01) | 11 (4) |
169 652 | – | 0.12 (0.02) | 16 (3) |
172 925 | – | 0.47 (0.04) | 28 (3) |
208 612 | TiO2JK,k = 4310,34–4211,31 | 0.09 (0.02) | 3 (3) |
209 295 | – | 0.22 (0.03) | 17 (2) |
216 602 | 13CN J = 2–1 hfs blend | 0.26 (0.03) | 8 (2) |
218 065 | – | 0.41 (0.02) | 3 (3) |
218 575 | – | 0.43 (0.03) | 24 (2) |
219 840 | 34SO2JK,k = 64,2–73,5 | 0.35 (0.04) | 3 (2) |
221 614 | – | 0.48 (0.04) | 18 (2) |
223 370 | SO18O JK,k = 64,2–73,5 | 0.35 (0.05) | 22 (3) |
224 876 | – | 1.98 (0.06) | 17 (2) |
250 807 | – | 0.15 (0.02) | 8 (3) |
252 256 | – | 0.20 (0.02) | 19 (3) |
252 531 | – | 0.45 (0.04) | 15 (3) |
254 677 | – | 0.34 (0.03) | 25 (3) |
263 452 | – | 0.12 (0.03) | 4 (2) |
271 968 | – | 0.44 (0.05) | 7 (2) |
306 192 | AlO N,J,F = 8,15/2,8–7,15/2,7 | 0.64 (0.08) | 22 (2) |
Notes. Column 3: integrated intensity (in antenna temperature) of the line with its formal uncertainty; Col. 4: expansion velocity derived from the linewidth with its uncertainty which includes the width of half a channel (1 MHz) except for the lines with a low S/N where a full channel (2 MHz) is included. The uncertainties given (within parentheses) do not include additional uncertainties derived from the absolute flux calibration and baseline subtraction.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.