Free Access

Table 2

KS comparison.

Tested distributions Time Median values (μi, μAD) KS probability KS probability, high values

log (M), A0 vs. B0, 2000 5 × 10-3 (–3.44, –3.03) 1.37 ×10-6 (4.8σ) 0.002 (2.76σ)
log (M), A0 vs. B0, 2000 10-2 (–3.43, –2.77) 9.2 ×10-6 (4.46σ) 0.005 (2.1σ)
log (M), A0 vs. B0, 5000 5 × 10-3 (–3.03, –2.68) 4.48 ×10-5 (4.1σ) 0.11 (1.5σ)
log (M), A0 vs. B0, 5000 10-2 (–3.21, –2.67) 0.12 (1.2σ) 0.04 (2.1σ)
log (rf), A0 vs. B0, 2000 5 × 10-3 (0.01,0.014) < 10-8 (5.7σ) 0.1 (1.7σ)
log (rf) A0 vs. B0, 2000 10-2 (0.014,0.019) < 10-8 (5.9σ) 0.0004 (3.4σ)
log (rf), A0 vs. B0, 5000 5 × 10-3 (0.01,0.013) 2.92 ×10-7 (5.12σ) 0.14 (1.45σ)
log (rf), A0 vs. B0, 5000 10-2 (0.0112,0.0116) 0.11 (1.56σ) 0.9 (0.05σ)
log (mass), A0l10 vs. B0l10, 2000 5 × 10-3 (–4.17, –3.73) < 10-8(> 7σ) < 10-8 (2.9σ)
log (mass), A0l10 vs. B0l10, 5000 5 × 10-3 (–3.85, –3.5) < 10-8 (> 7σ) 8 × 10-7 (2.6σ)
log (rf), A0l10 vs. B0l10, 2000 5 × 10-3 (0.006,0.008) < 10-8 (> 7σ) 0.4 (0.87σ)
log (rf), A0l10 vs. B0l10, 5000 5 × 10-3 (0.005,0.007) < 10-8 (> 7σ) 0.38 (2σ)
log (M), A1 vs. B1, 2000 5 × 10-3 (–3.29, –2.92) 0.001 (3.19σ) 0.04 (2σ)
log (M), A1 vs. B1, 2000 10-2 (–3.17, –2.86) 0.002 (3.1σ) 0.33 (1σ)
log (M), A1 vs. B1, 5000 5 × 10-3 (–3.29, –2.86) 0.0014 (3.1σ) 0.9 (0.1σ)
log (M), A1 vs. B1, 5000 10-2 (–2.92, –2.72) 0.13 (1.5σ) 0.12 (1.54σ)
log (rf), A1 vs. B1, 2000 5 × 10-3 (0.011, 0.015) 0.004 (2.9σ) 0.61 (0.5σ)
log (rf), A1 vs. B1, 2000 10-2 (0.013, 0.016) 0.003 (3σ) 0.2 (1.3σ)
log (rf), A1 vs. B1, 5000 5 × 10-3 (0.01, 0.012) 0.01 (2.56σ) 0.6 (0.6σ)
log (rf), A1 vs. B1, 5000 10-2 (0.011, 0.012) 0.21 (1.24σ) 0.01 (2.54σ)

Notes. The first column lists the compared distribution pairs, indicating the measured quantity (mass M or thickness rf), the names of the simulations and the density threshold in cm-3. The second column lists the timestep in code units (see text) and the third lists the median values of the two distributions, ideal (μi) and non-ideal (μAD). The last two columns contain the KS probability: the fourth gives the result for the full samples and the last only for the high-value end (10-1.7 pc for the thickness and 10-3M for the mass). The same columns in parentheses include the probability in sigma levels. We mention < 10-8 when the probability is essentially zero.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.