Table 4
Best-fit parameters of the spectra using Chandra observations of M101 ULX-1 in the 0.3–7 keV energy range.
ObsID | MJD, day | Exp, ks | Counts | kTs, keV | Γbmc = αbmc + 1 | log A | N bmc † | ![]() |
|
||||||||
934 | 51 629 | 94 | 8642 | 100±21 | 2.78±0.08 | –3.78(9) | 35.2(3) | 0.99 (28) |
2065 | 51 846 | 10 | 310 | 67±10 | 2.6±0.1 | –2.36(8) | 18.9(1) | 1.08 (10) |
4731* | 53 023 | 56 | 26 | 46±10 | 1.39±0.07 | –2.1(5) | 2.2(1) | 0.89 |
5297* | 53 028 | 15 | 14 | 42±9 | 1.38±0.04 | –2.0(6) | 2.3(2) | 0.78 |
5300* | 53 071 | 52 | 13 | 43±8 | 1.38±0.05 | –2.0(6) | 2.2(1) | 0.99 |
5309* | 53 078 | 71 | 18 | 44±9 | 1.37±0.06 | –2.0(5) | 2.1(1) | 0.98 |
4732* | 53 083 | 70 | 12 | 42±8 | 1.38±0.04 | –2.0(3) | 2.1(1) | 0.91 |
5322* | 53 128 | 65 | 17 | 45±10 | 1.39±0.08 | –2.0(5) | 2.2(1) | 0.93 |
4733* | 53 132 | 16 | 12 | 41±7 | 1.36±0.07 | –2.0(4) | 2.1(1) | 0.85 |
5323* | 53 134 | 43 | 10 | 40±10 | 1.35±0.09 | –2.5(2) | 2.0(1) | 0.82 |
5337 | 53 191 | 10 | 129 | 70±12 | 1.65±0.09 | –3.32(9) | 4.6(2) | 0.97 (12) |
5338 | 53 192 | 28 | 162 | 98±25 | 1.89±0.07 | –2.93(8) | 6.3(1) | 1.00 (30) |
5339 | 53 193 | 14 | 468 | 65±14 | 1.97±0.1 | –4.18(6) | 6.9(1) | 1.08 (20) |
5340 | 53 194 | 54 | 680 | 51±3 | 2.72±0.09 | –2.4(3) | 30.6(3) | 1.21 (23) |
4734 | 53 197 | 35 | 582 | 60±9 | 2.12±0.06 | –3.9(4) | 8.7(1) | 1.25 (14) |
4736* | 53 310 | 78 | 29 | 45±8 | 1.36±0.07 | –2.4(2) | 2.0(1) | 0.89 |
6152* | 53 316 | 44 | 21 | 43±9 | 1.36±0.08 | –2.4(3) | 2.1(2) | 0.96 |
6170 | 53 361 | 48 | 41 | 47±12 | 1.5±0.1 | –2.0(1) | 3.1(5) | 0.6 (5) |
6175 | 53 363 | 41 | 54 | 45±10 | 1.9±0.3 | –3.7(1) | 5.7(1) | 0.78 (6) |
6169 | 53 369 | 29 | 613 | 71±5 | 2.1±0.1 | –4.1(2) | 8.1(1) | 1.12 (20) |
4737 | 53 371 | 20 | 1483 | 95±7 | 2.75±0.06 | –3.9(1) | 26.7(1) | 1.08 (54) |
Comb.LH** | ... | 500 | 172 | 45±10 | 1.39±0.08 | –2.0(5) | 2.2(1) | 0.93 (10) |
Notes. Parameter errors correspond to 90% confidence level. The spectral model is phabs*BMC, where NH is 3 × 1021 cm-2 as a best-fit neutral absorption obtained for both Chandra and Swift spectra for the low/hard and high/soft states.
Normalization parameters of BMC component is in units of erg/s/kpc2, where L35 is the source luminosity in units of 1035 erg s-1,
is the distance to the source in units of 10 kpc;
for the low state data, we fit the spectrum using CASH statistic. In this case the goodness-of-fit is determined by Monte-Carlo simulations.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.