Table A.2
Laboratory parameters of CH3CN and and the intensity integrated over the width of each line
, which is used for rotation diagrams in Fig. 8.
Mol. | Freq | K | I(300K) | E L | Sul μ2 | o-/p- | HC | mm2 | mm3a | mm3b | NE | Note |
(GHz) | Log10 | (cm-1) | (D2) | (K km s-1) | (K km s-1) | (K km s-1) | (K km s-1) | (K km s-1) | ||||
CH3CN (J = 12 → 11) | 220.476 | 8 | −3.098 | 357.938 | 205.033 | p- | 73.64± 2.81 | 16.46± 1.14 | 11.22± 0.85 | 7.67± 1.06 | ≤ 0.31 | 1, 2, 3, 4 |
220.539 | 7 | −2.868 | 283.608 | 243.499 | p- | 144.31± 3.70 | 49.48± 1.90 | 27.68± 1.16 | 33.72± 1.52 | ≤ 0.61 | ||
220.594 | 6 | −2.377 | 219.154 | 553.690 | o- | 356.10± 7.70 | 150.47± 10.38 | 90.69± 11.98 | 190.53± 2.74 | 0.71± 0.53 | ||
220.641 | 5 | −2.522 | 164.592 | 305.047 | p- | 327.23± 32.55 | 146.62± 4.76 | 106.37± 10.00 | 178.31± 5.00 | 1.34± 0.63 | ||
220.679 | 4 | −2.397 | 119.933 | 328.188 | p- | 307.21± 25.39 | 150.29± 5.73 | 142.61± 2.77 | 170.24± 10.00 | 5.11± 0.36 | ||
220.709 | 3 | −2.001 | 85.187 | 692.234 | o- | 484.10± 10.61 | 209.82± 15.40 | 278.38± 7.16 | 319.87± 13.08 | 11.92± 0.56 | ||
220.730 | 2 | −2.234 | 60.363 | 358.988 | p- | 397.54± 9.19 | 281.55± 10.27 | 256.41± 27.26 | 331.98± 21.20 | 15.17± 1.00 | ||
220.743 | 1 | −2.194 | 45.467 | 366.614 | p- | 371.68± 28.18 | 229.32± 8.17 | 247.64± 10.46 | 284.65± 25.77 | 13.52± 0.66 | ||
220.747 | 0 | −2.180 | 40.501 | 369.277 | p- | 372.96± 28.18 | 211.34± 4.55 | 255.62± 1.40 | 348.84± 25.77 | 11.19± 0.37 | ||
![]() |
220.431 | 7 | −2.707 | 283.596 | 243.492 | p- | 4.07± 1.61 | 2, 3, 5 | ||||
220.485 | 6 | −2.216 | 219.141 | 553.669 | o- | 14.29± 1.28 | ||||||
220.532 | 5 | −2.361 | 164.575 | 305.101 | p- | 16.78± 1.80 | ||||||
220.570 | 4 | −2.236 | 119.915 | 328.169 | p- | 27.41± 1.75 | ||||||
220.621 | 2 | −2.073 | 60.344 | 358.964 | p- | 96.44± 4.41 |
Notes. Uncertainties on the measured intensities are typically ≤10% (written as the subscript), as determined from Gaussian fitting. 1) None detection is given by an upper limit of 3σ rms; 2) integrated intensities are obtained by Gildas “Gaussian” fittings; 3) laboratory parameters are given from CDMS; 4) Q(300 K, CH3CN) = 14 683.6324; 5) Q(300 K, ) = 199 602.70.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.