Table 1
Root-mean-square (rms) deviations from the global fita of transitions involving vt = 0 torsional energy levels of deuterated methyl formate (DCOOCH3).
Number of parameters | 27 | |||||
Number of lines | 3763 | |||||
rms of the 3763 vt = 0-0 lines | 0.1043 MHz | |||||
rms of the 2232 A symmetry lines | 0.1072 MHz | |||||
rms of the 1531 E symmetry lines | 0.0998 MHz | |||||
|
||||||
Sourceb | Rangec (GHz) | Jmax, Kmaxd | Number of linese | Uncertaintiesf (MHz) | rmsg (MHz) | σ h |
|
||||||
FTMW-Lille | 4–18 | 7,4 | 18 | 0.003 | 0.0029 | 0.96 |
21 | 0.010 | 0.0181 | 1.81 | |||
|
||||||
BWO-Lille | 580–661 | 64,36 | 485 | 0.050 | 0.0506 | 1.01 |
|
||||||
OEST | 91–377 | 30,25 | 816 | 0.080 | 0.0581 | 0.73 |
|
||||||
BWO-Lille | 580–661 | 57,29 | 50 | 0.100 | 0.1041 | 1.04 |
JPLi | 850–1205 | 69,36 | 1814 | 0.100 | ||
|
||||||
OSLO | 7–80 | 48,16 | 260 | 0.150 | ||
16 | 0.200 | |||||
BWO-Lille | 580–661 | 57,35 | 31 | 0.200 | 0.1728 | 0.94 |
CURL | 227–290 | 5, 1 | 5 | 0.200 | ||
OEST | 91–377 | 26, 6 | 10 | 0.200 | ||
JPLi | 1205–1466 | 69,35 | 237 | 0.200 |
Notes.
Parameter values are given in Table 2. The complete list of observed minus calculated residuals of vt = 0 lines are given in supplementary Table A.1.
Sources of data: OEST (Oesterling et al. 1995); BWO-Lille, FTMW-Lille and OSLO data come from Margulès et al. (2010) and CURL data come from (Curl 1959). JPL data have been measured in this work.
Unitless standard deviation of each set of measurements (where the differences between the observed and calculated frequencies in the standard deviation formula are weighted with their experimental uncertainties).
The spectrometer spectral range for these measurements is 850–1466 GHz. The experimental uncertainty is generally better than 0.100 MHz for isolated lines below 1205 GHz, but some lines are either blended or present a poor signal-to-noise ratio, therefore their measurement accuracy was taken to be 0.200 MHz according to the broadening of the experimental line. Above 1205 GHz, the experimental uncertainty for isolated lines is considered better than 0.200 MHz.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.